Membrane-assisted radiant cooling for expanding thermal comfort zones globally without air conditioning

We present results of a radiant cooling system that made the hot and humid tropical climate of Singapore feel cool and comfortable. Thermal radiation exchange between occupants and surfaces in the built environment can augment thermal comfort. The lack of widespread commercial adoption of radiant-co...

Full description

Saved in:
Bibliographic Details
Published inProceedings of the National Academy of Sciences - PNAS Vol. 117; no. 35; pp. 21162 - 21169
Main Authors Teitelbaum, Eric, Chen, Kian Wee, Aviv, Dorit, Bradford, Kipp, Ruefenacht, Lea, Sheppard, Denon, Teitelbaum, Megan, Meggers, Forrest, Pantelic, Jovan, Rysanek, Adam
Format Journal Article
LanguageEnglish
Published Washington National Academy of Sciences 01.09.2020
Subjects
Online AccessGet full text
ISSN0027-8424
1091-6490
1091-6490
DOI10.1073/pnas.2001678117

Cover

More Information
Summary:We present results of a radiant cooling system that made the hot and humid tropical climate of Singapore feel cool and comfortable. Thermal radiation exchange between occupants and surfaces in the built environment can augment thermal comfort. The lack of widespread commercial adoption of radiant-cooling technologies is due to two widely held views: 1) The low temperature required for radiant cooling in humid environments will form condensation; and 2) cold surfaces will still cool adjacent air via convection, limiting overall radiant-cooling effectiveness. This work directly challenges these views and provides proof-ofconcept solutions examined for a transient thermal-comfort scenario. We constructed a demonstrative outdoor radiant-cooling pavilion in Singapore that used an infrared-transparent, lowdensity polyethylene membrane to provide radiant cooling at temperatures below the dew point. Test subjects who experienced the pavilion (n = 37) reported a “satisfactory” thermal sensation 79% of the time, despite experiencing 29.6 ± 0.9 °C air at 66.5 ± 5% relative humidity and with low air movement of 0.26 ± 0.18 m−1. Comfort was achieved with a coincident mean radiant temperature of 23.9 ± 0.8 °C, requiring a chilled water-supply temperature of 17.0 ± 1.8 °C. The pavilion operated successfully without any observed condensation on exposed surfaces, despite an observed dew-point temperature of 23.7 ± 0.7 °C. The coldest conditions observed without condensation used a chilled water-supply temperature 12.7 °C below the dew point, which resulted in a mean radiant temperature 3.6 °C below the dew point.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
Edited by Alexis T. Bell, University of California, Berkeley, CA, and approved July 20, 2020 (received for review January 28, 2020)
Author contributions: E.T., K.W.C., D.A., K.B., L.R., D.S., M.T., F.M., J.P., and A.R. designed research; E.T., K.W.C., D.A., K.B., L.R., D.S., M.T., F.M., J.P., and A.R. performed research; E.T., K.W.C., M.T., F.M., J.P., and A.R. analyzed data; and E.T., K.W.C., and D.A. wrote the paper.
ISSN:0027-8424
1091-6490
1091-6490
DOI:10.1073/pnas.2001678117