Evaluation of Atrial Septal Defect Using Real-time Three-dimensional Echocardiography: Comparison with Surgical Findings
The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was perf...
        Saved in:
      
    
          | Published in | Journal of Huazhong University of Science and Technology. Medical sciences Vol. 29; no. 2; pp. 257 - 259 | 
|---|---|
| Main Authors | , , , , , , , , , , , , , , | 
| Format | Journal Article | 
| Language | English | 
| Published | 
        Heidelberg
          Huazhong University of Science and Technology
    
        01.04.2009
     Department of Pediatric Cardiovascular and Rheumatic Diseases,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,China%Department of Medical Ultrasound,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,China%Department of Epidemiology and Biostatistics,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,China%Department of Cardiovascular Diseases,Aghakhan Hospital,Dares Salaam,Tanzania,Wuhan 430030,China  | 
| Subjects | |
| Online Access | Get full text | 
| ISSN | 1672-0733 1993-1352  | 
| DOI | 10.1007/s11596-009-0225-y | 
Cover
| Summary: | The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes. | 
|---|---|
| Bibliography: | two dimensional echocardiography 42-1679/R R540.45 real-time three-dimensional echocardiography R654.2 atrial septal defect real-time three-dimensional echocardiography; atrial septal defect; two dimensional echocardiography ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 ObjectType-Undefined-3  | 
| ISSN: | 1672-0733 1993-1352  | 
| DOI: | 10.1007/s11596-009-0225-y |