Biomarker reproducibility in exhaled breath condensate collected with different condensers

Optimal collection and analysis of exhaled breath condensate (EBC) are prerequisites for standardisation and reproducibility of assessments. The present study aimed to assess reproducibility of EBC volume, hydrogen peroxide (H 2 O 2 ), 8-isoprostane and cytokine measurements using different condense...

Full description

Saved in:
Bibliographic Details
Published inThe European respiratory journal Vol. 31; no. 5; pp. 934 - 942
Main Authors Rosias, P. P, Robroeks, C. M, Kester, A, den Hartog, G. J, Wodzig, W. K, Rijkers, G. T, Zimmermann, L. J, van Schayck, C. P, Jobsis, Q, Dompeling, E
Format Journal Article
LanguageEnglish
Published Leeds Eur Respiratory Soc 01.05.2008
Maney
Subjects
Online AccessGet full text
ISSN0903-1936
1399-3003
1399-3003
DOI10.1183/09031936.00073207

Cover

More Information
Summary:Optimal collection and analysis of exhaled breath condensate (EBC) are prerequisites for standardisation and reproducibility of assessments. The present study aimed to assess reproducibility of EBC volume, hydrogen peroxide (H 2 O 2 ), 8-isoprostane and cytokine measurements using different condensers, including a newly developed glass condenser. At four points in time, 30 healthy subjects performed sequential EBC collections randomly using the following four condensers: glass, silicone, EcoScreen® (Erich Jaeger GmbH, Hoechberg, Germany) and an optimised glass condenser. In small EBC samples, H 2 O 2 was measured by spectrophotometer, 8-isoprostane by enzyme immunoassay, and cytokines by multiplexed xMAP® technology (Luminex Corporation, Austin, TX, USA). The optimised glass condenser yielded significantly more EBC volume (median 2,025 µL, interquartile range 1,600–2,525). The reproducibility of EBC volume, yielded by the new glass condenser, was comparable with EcoScreen® (19–20 coefficients of variation (CV)%), but was significantly better compared with silicone and glass (29–37 CV%). The new condenser was associated with significantly more detections of H 2 O 2 , 8-isoprostane, interleukin-2, -4, -5 and -13, and tumour necrosis factor-α. Isoprostane concentrations were significantly higher using the new condenser, whereas H 2 O 2 and cytokine concentrations were not. Reproducibility of biomarkers was equally variable for all condenser types. In conclusion, significantly more exhaled breath condensate volume and biomarker detections were found using the optimised glass condenser, including higher 8-isoprostane levels. However, biomarker reproducibility in exhaled breath condensate in healthy adults was not influenced by the type of condenser.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
ISSN:0903-1936
1399-3003
1399-3003
DOI:10.1183/09031936.00073207