Incidence and predictors of new-onset atrioventricular block requiring pacemaker implantation after sutureless aortic valve replacement
In high-risk patients with severe aortic stenosis, aortic valve replacement (AVR) with a sutureless Perceval prosthesis (SU-AVR) can be performed instead of conventional AVR or transcatheter aortic valve implantation. Little data are available regarding postoperative conduction disorders after SU-AV...
Saved in:
Published in | Interactive cardiovascular and thoracic surgery Vol. 23; no. 6; pp. 861 - 868 |
---|---|
Main Authors | , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
England
01.12.2016
|
Subjects | |
Online Access | Get full text |
ISSN | 1569-9293 1569-9285 1569-9285 |
DOI | 10.1093/icvts/ivw259 |
Cover
Summary: | In high-risk patients with severe aortic stenosis, aortic valve replacement (AVR) with a sutureless Perceval prosthesis (SU-AVR) can be performed instead of conventional AVR or transcatheter aortic valve implantation. Little data are available regarding postoperative conduction disorders after SU-AVR. We aimed to determine the incidence and predictors of new-onset complete atrioventricular block (NO-AVB) requiring permanent cardiac stimulation following SU-AVR.
We studied consecutive patients who underwent SU-AVR between 2013 and 2015. Early patients underwent partial aortic decalcification and subannular valve implantation (standard technique), while later patients underwent complete/symmetrical decalcification and intra-annular valve deployment (modified technique). Predictive baseline and procedural variables and electrocardiographic parameters were identified using a logistic regression model.
We included 140 patients (mean age, 78 ± 6.5 years; mean Log EuroSCORE II, 8.9 ± 10%; 28.6% concomitant myocardial revascularization). The most common postoperative conduction disturbances were LBBB (25%), NO-AVB (12.1%) and first-degree atrioventricular block (AVB) (7.9%). The incidence of NO-AVB was 61% lower with the modified versus the standard technique (P= 0.04). NO-AVB predominantly appeared within 24 h post-surgery, occurring >24 h post-surgery in only 2 patients (both with baseline conduction defects). Independent predictors of NO-AVB included baseline left QRS axis deviation (LaQD; P= 0.03), first-degree AVB (P< 0.01) and standard surgical technique (P= 0.02).
NO-AVB is a frequent complication following SU-AVR, and its incidence strongly depends on the surgical technique. Baseline first-degree AVB and LaQD independently predict NO-AVB and should be considered when deciding the duration of postoperative electrocardiographic monitoring. |
---|---|