Use of Embolic Protection Devices during Hybrid Thoracic Endovascular Aortic Repair for a Shaggy Aorta: A Case Report
An 87-year-old man presented with a saccular aneurysm at the proximal descending thoracic aorta. As computed tomography revealed a shaggy aorta, we planned hybrid thoracic endovascular aortic repair (TEVAR) with embolic protection devices (EPDs) in both internal carotid arteries to prevent a cerebro...
Saved in:
Published in | Journal of chest surgery Vol. 54; no. 6; pp. 513 - 516 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | English |
Published |
Korea (South)
The Korean Society for Thoracic and Cardiovascular Surgery
05.12.2021
Korean Society for Thoracic & Cardiovascular Surgery 대한흉부외과학회 |
Subjects | |
Online Access | Get full text |
ISSN | 2765-1606 2765-1614 |
DOI | 10.5090/jcs.21.017 |
Cover
Summary: | An 87-year-old man presented with a saccular aneurysm at the proximal descending thoracic aorta. As computed tomography revealed a shaggy aorta, we planned hybrid thoracic endovascular aortic repair (TEVAR) with embolic protection devices (EPDs) in both internal carotid arteries to prevent a cerebrovascular accident. We inserted an Emboshield NAV
Embolic Protection System (Abbott Vascular, Abbott Park, IL, USA) into both internal carotid arteries before performing the TEVAR procedure. The patient was discharged from the hospital on postoperative day 4 without any neurological complications. |
---|---|
Bibliography: | ObjectType-Case Study-2 SourceType-Scholarly Journals-1 ObjectType-Feature-4 content type line 23 ObjectType-Report-1 ObjectType-Article-3 |
ISSN: | 2765-1606 2765-1614 |
DOI: | 10.5090/jcs.21.017 |