Multispectral diffusion‐weighted imaging near metal implants

Purpose The need for diffusion‐weighted‐imaging (DWI) near metallic implants is becoming increasingly relevant for a variety of clinical diagnostic applications. Conventional DWI methods are significantly hindered by metal‐induced image artifacts. A novel approach relying on multispectral susceptibi...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 79; no. 2; pp. 987 - 993
Main Authors Koch, Kevin M., Bhave, Sampada, Gaddipati, Ajeet, Hargreaves, Brian A., Gui, Dawei, Peters, Robert, Bedi, Meena, Mannem, Rajeev, Kaushik, S. Sivaram
Format Journal Article
LanguageEnglish
Published United States Wiley Subscription Services, Inc 01.02.2018
Subjects
Online AccessGet full text
ISSN0740-3194
1522-2594
1522-2594
DOI10.1002/mrm.26737

Cover

More Information
Summary:Purpose The need for diffusion‐weighted‐imaging (DWI) near metallic implants is becoming increasingly relevant for a variety of clinical diagnostic applications. Conventional DWI methods are significantly hindered by metal‐induced image artifacts. A novel approach relying on multispectral susceptibility artifact reduction techniques is presented to address this unmet need. Methods DWI near metal implants is achieved through a combination of several advanced MRI acquisition technologies. Previously described approaches to Carr–Purcell–Meiboom–Gill spin‐echo train DWI sequences using the periodically rotated overlapping parallel lines with enhanced reconstruction are combined with multispectral‐imaging metal artifact reduction principles to provide DWI with substantially reduced artifact levels. The presented methods are applied to limited sets of slices over areas of sarcoma risk near six implanted devices. Results Using the presented methods, DWI assessment without bulk image distortions is demonstrated in the immediate vicinity of metallic interfaces. In one subject, the apparent diffusion coefficient was reduced in a region of suspected sarcoma directly adjacent to fixation hardware. Conclusions An initial demonstration of minimal‐artifact multispectral DWI in the near vicinity of metallic hardware is described and successfully demonstrated on clinical subjects. Magn Reson Med 79:987–993, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Bibliography:Drs. Gaddipati, Gui, Peters, and Kaushik are employed by GE Healthcare.