Image denoising for real‐time MRI

Purpose To develop an image noise filter suitable for MRI in real time (acquisition and display), which preserves small isolated details and efficiently removes background noise without introducing blur, smearing, or patch artifacts. Theory and Methods The proposed method extends the nonlocal means...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 77; no. 3; pp. 1340 - 1352
Main Authors Klosowski, Jakob, Frahm, Jens
Format Journal Article
LanguageEnglish
Published United States Wiley Subscription Services, Inc 01.03.2017
Subjects
Online AccessGet full text
ISSN0740-3194
1522-2594
1522-2594
DOI10.1002/mrm.26205

Cover

More Information
Summary:Purpose To develop an image noise filter suitable for MRI in real time (acquisition and display), which preserves small isolated details and efficiently removes background noise without introducing blur, smearing, or patch artifacts. Theory and Methods The proposed method extends the nonlocal means algorithm to adapt the influence of the original pixel value according to a simple measure for patch regularity. Detail preservation is improved by a compactly supported weighting kernel that closely approximates the commonly used exponential weight, while an oracle step ensures efficient background noise removal. Denoising experiments were conducted on real‐time images of healthy subjects reconstructed by regularized nonlinear inversion from radial acquisitions with pronounced undersampling. Results The filter leads to a signal‐to‐noise ratio (SNR) improvement of at least 60% without noticeable artifacts or loss of detail. The method visually compares to more complex state‐of‐the‐art filters as the block‐matching three‐dimensional filter and in certain cases better matches the underlying noise model. Acceleration of the computation to more than 100 complex frames per second using graphics processing units is straightforward. Conclusion The sensitivity of nonlocal means to small details can be significantly increased by the simple strategies presented here, which allows partial restoration of SNR in iteratively reconstructed images without introducing a noticeable time delay or image artifacts. Magn Reson Med 77:1340–1352, 2017. © 2016 International Society for Magnetic Resonance in Medicine
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
ISSN:0740-3194
1522-2594
1522-2594
DOI:10.1002/mrm.26205