Percutaneous decannulation of venoarterial extracorporeal membrane oxygenation using the Manta vascular closure device: A systematic review and meta‐analysis
To perform a systematic review and meta-analysis of the techniques and outcomes associated with percutaneous decannulation of venoarterial extracorporeal membrane oxygenation (VA-ECMO) using the Manta vascular closure device. Peripheral VA-ECMO can be used to treat critically ill patients with condi...
Saved in:
Published in | Artificial organs Vol. 47; no. 9; pp. 1431 - 1441 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
Wiley Subscription Services, Inc
01.09.2023
|
Subjects | |
Online Access | Get full text |
ISSN | 0160-564X 1525-1594 1525-1594 |
DOI | 10.1111/aor.14554 |
Cover
Summary: | To perform a systematic review and meta-analysis of the techniques and outcomes associated with percutaneous decannulation of venoarterial extracorporeal membrane oxygenation (VA-ECMO) using the Manta vascular closure device.
Peripheral VA-ECMO can be used to treat critically ill patients with conditions such as refractory cardiogenic shock. After percutaneous implantation of VA-ECMO, VA-ECMO can also be decannulated completely percutaneously by using a vascular closure device. The Manta vascular closure device is a dedicated device used in the closure of large-bore arteriotomies by sandwiching the arteriotomy with an intra-arterial toggle and an extraluminal collagen plug.
We performed a thorough literature search using various electronic databases. We included studies that reported outcomes after peripheral femorofemoral VA-ECMO decannulation with the Manta vascular closure device. We performed a meta-analysis of proportions on outcome measures, including technical success, bleeding complications, vascular complications, wound complications, major amputation, and procedural-related deaths.
We included seven studies with a total of 116 patients. The overall technical success of percutaneous decannulation of VA-ECMO with the Manta vascular closure device was 93.7%. The overall incidence of bleeding, vascular and wound complications was 1.7%, 13.8%, and 3.4%, respectively. No patient required lower limb amputation or died due to VA-ECMO decannulation.
Percutaneous decannulation with the Manta vascular closure device is an effective and safe procedure that should be considered in suitable patients on VA-ECMO. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 ObjectType-Article-2 ObjectType-Feature-1 ObjectType-Review-4 content type line 23 ObjectType-Undefined-3 |
ISSN: | 0160-564X 1525-1594 1525-1594 |
DOI: | 10.1111/aor.14554 |