Maternal cell contamination in postnatal umbilical cord blood samples implies a low risk for genetic misdiagnoses

Objective Maternal cell contamination (MCC) poses a risk for misdiagnosis in prenatal genetic testing, and is examined in accredited diagnostic laboratories However, the awareness of possible MCC in perinatal/postnatal genetic testing, mainly of umbilical cord blood (CB), is lower. Method We investi...

Full description

Saved in:
Bibliographic Details
Published inPrenatal diagnosis Vol. 44; no. 11; pp. 1304 - 1309
Main Authors Smeekens, Sanne P., Leferink, Maike, Yntema, Helger G., Kamsteeg, Erik‐Jan
Format Journal Article
LanguageEnglish
Published England Wiley Subscription Services, Inc 01.10.2024
Subjects
Online AccessGet full text
ISSN0197-3851
1097-0223
1097-0223
DOI10.1002/pd.6595

Cover

More Information
Summary:Objective Maternal cell contamination (MCC) poses a risk for misdiagnosis in prenatal genetic testing, and is examined in accredited diagnostic laboratories However, the awareness of possible MCC in perinatal/postnatal genetic testing, mainly of umbilical cord blood (CB), is lower. Method We investigated the rate of MCC in DNA from both umbilical CB samples and umbilical cord samples that were sent to our diagnostic laboratory for diagnostic testing between 1995 and 2021 (n = 236). Results MCC was detected in 4% of umbilical CB samples, and in one umbilical cord sample. Particularly tests enriching for a specific variant are very sensitive for low amounts of MCC, as we emphasize here with a false positive diagnosis of myotonic dystrophy type 1 in a newborn. Conclusions Overall, with appropriate collection and use, umbilical CB and umbilical cord samples are suitable for genetic testing based on the low rates of MCC and misdiagnosis. These findings do however underline the importance of routine MCC testing in umbilical CB samples and umbilical cord samples for both requesting clinicians and diagnostic genetic laboratories. Key points What is already known about this topic? Maternal cell contamination (MCC) poses a risk of misdiagnosis in prenatal genetic testing. Umbilical cord blood (CB) is a safe and non‐invasive alternative for venal puncture blood withdrawal in newborns. What does this study add? MCC poses a low risk of misdiagnosis in perinatal genetic testing performed from umbilical CB. Polymerase chain reaction‐based tests for repeat expansions are very sensitive to contamination.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0197-3851
1097-0223
1097-0223
DOI:10.1002/pd.6595