Robust navigation support in lowest dose image setting

Purpose Clinical cardiac electrophysiology (EP) is concerned with diagnosis and treatment of cardiac arrhythmia describing abnormality or perturbation in the normal activation sequence of the myocardium. With the recent introduction of lowest dose X-ray imaging protocol for EP procedures, interventi...

Full description

Saved in:
Bibliographic Details
Published inInternational journal for computer assisted radiology and surgery Vol. 14; no. 2; pp. 291 - 300
Main Authors Bui, Mai, Bourier, Felix, Baur, Christoph, Milletari, Fausto, Navab, Nassir, Demirci, Stefanie
Format Journal Article
LanguageEnglish
Published Cham Springer International Publishing 01.02.2019
Springer Nature B.V
Subjects
Online AccessGet full text
ISSN1861-6410
1861-6429
1861-6429
DOI10.1007/s11548-018-1874-8

Cover

More Information
Summary:Purpose Clinical cardiac electrophysiology (EP) is concerned with diagnosis and treatment of cardiac arrhythmia describing abnormality or perturbation in the normal activation sequence of the myocardium. With the recent introduction of lowest dose X-ray imaging protocol for EP procedures, interventional image enhancement has gained crucial importance for the well-being of patients as well as medical staff. Methods In this paper, we introduce a novel method to detect and track different EP catheter electrodes in lowest dose fluoroscopic sequences based on ℓ 1 -sparse coding and online robust PCA (ORPCA) . Besides being able to work on real lowest dose sequences, the underlying methodology achieves simultaneous detection and tracking of three main EP catheters used during ablation procedures. Results We have validated our algorithm on 16 lowest dose fluoroscopic sequences acquired during real cardiac ablation procedures. In addition to expert labels for 2 sequences, we have employed a crowdsourcing strategy to obtain ground truth labels for the remaining 14 sequences. In order to validate the effect of different training data, we have employed a leave-one-out cross-validation scheme yielding an average detection rate of 86.9 % . Conclusion Besides these promising quantitative results, our medical partners also expressed their high satisfaction. Being based on ℓ 1 -sparse coding and online robust PCA (ORPCA) , our method advances previous approaches by being able to detect and track electrodes attached to multiple different catheters.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1861-6410
1861-6429
1861-6429
DOI:10.1007/s11548-018-1874-8