Patient-specific instrumentation in primary total shoulder arthroplasty: a meta-analysis of clinical outcomes
The introduction of patient-specific instrumentation (PSI) in total shoulder arthroplasty (TSA) has improved implant positioning accuracy. However, whether PSI yields additional clinical benefit compared to standard instrumentation (SI) in the setting of primary TSA (anatomic and reverse) remains un...
Saved in:
Published in | Clinics in Shoulder and Elbow Vol. 28; no. 2; pp. 129 - 136 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Korea (South)
Korean Shoulder and Elbow Society
01.06.2025
대한견주관절학회 |
Subjects | |
Online Access | Get full text |
ISSN | 2383-8337 2288-8721 |
DOI | 10.5397/cise.2024.01095 |
Cover
Summary: | The introduction of patient-specific instrumentation (PSI) in total shoulder arthroplasty (TSA) has improved implant positioning accuracy. However, whether PSI yields additional clinical benefit compared to standard instrumentation (SI) in the setting of primary TSA (anatomic and reverse) remains unclear.
PubMed, Cochrane, Embase, and Google Scholar were queried through August 2024. Inclusion criteria consisted of studies that compared PSI to SI in TSA (anatomic and reverse). Key outcomes analyzed included adverse events, patient-reported outcomes, and discrepancies between planned and achieved implant positioning.
Five retrospective studies, three randomized controlled trials, and one prospective study met the inclusion criteria. There was no difference in complications (odds ratio [OR], 1.00; 95% CI, 0.16 to 6.10; P=1.00), reoperation (OR, 1.35; 95% CI, 0.37 to 4.91; P=0.65), American Shoulder and Elbow Surgeons score (mean difference [MD], 1.61; 95% CI, -4.08 to 7.30; P=0.58), Constant-Murley Score (MD, 3.06; 95% CI, -3.68 to 9.81; P=0.37), version error (MD, -0.76; 95% CI, -2.51 to 0.99; P=0.40), and inclination error (MD, -2.89; 95% CI, -5.82 to 0.05; P=0.05) between the two groups.
This study found no significant differences in patient-reported outcomes, complication rates, or implant positioning accuracy between PSI and SI in primary TSA. Future randomized controlled trials comparing these two types of instrumentation would be useful to assess whether a benefit exists for PSI in the setting of primary TSA. Level of evidence: III. |
---|---|
Bibliography: | http://www.cisejournal.org/journal/view.php?doi=10.5397/cise.2024.01095 |
ISSN: | 2383-8337 2288-8721 |
DOI: | 10.5397/cise.2024.01095 |