Patient-specific instrumentation in primary total shoulder arthroplasty: a meta-analysis of clinical outcomes

The introduction of patient-specific instrumentation (PSI) in total shoulder arthroplasty (TSA) has improved implant positioning accuracy. However, whether PSI yields additional clinical benefit compared to standard instrumentation (SI) in the setting of primary TSA (anatomic and reverse) remains un...

Full description

Saved in:
Bibliographic Details
Published inClinics in Shoulder and Elbow Vol. 28; no. 2; pp. 129 - 136
Main Authors Daher, Mohammad, Parmar, Tarishi, Boufadel, Peter, Fares, Mohamad Y, Khalil, Wissam, Horneff, John G, Abboud, Joseph A, Khan, Adam Z
Format Journal Article
LanguageEnglish
Published Korea (South) Korean Shoulder and Elbow Society 01.06.2025
대한견주관절학회
Subjects
Online AccessGet full text
ISSN2383-8337
2288-8721
DOI10.5397/cise.2024.01095

Cover

More Information
Summary:The introduction of patient-specific instrumentation (PSI) in total shoulder arthroplasty (TSA) has improved implant positioning accuracy. However, whether PSI yields additional clinical benefit compared to standard instrumentation (SI) in the setting of primary TSA (anatomic and reverse) remains unclear. PubMed, Cochrane, Embase, and Google Scholar were queried through August 2024. Inclusion criteria consisted of studies that compared PSI to SI in TSA (anatomic and reverse). Key outcomes analyzed included adverse events, patient-reported outcomes, and discrepancies between planned and achieved implant positioning. Five retrospective studies, three randomized controlled trials, and one prospective study met the inclusion criteria. There was no difference in complications (odds ratio [OR], 1.00; 95% CI, 0.16 to 6.10; P=1.00), reoperation (OR, 1.35; 95% CI, 0.37 to 4.91; P=0.65), American Shoulder and Elbow Surgeons score (mean difference [MD], 1.61; 95% CI, -4.08 to 7.30; P=0.58), Constant-Murley Score (MD, 3.06; 95% CI, -3.68 to 9.81; P=0.37), version error (MD, -0.76; 95% CI, -2.51 to 0.99; P=0.40), and inclination error (MD, -2.89; 95% CI, -5.82 to 0.05; P=0.05) between the two groups. This study found no significant differences in patient-reported outcomes, complication rates, or implant positioning accuracy between PSI and SI in primary TSA. Future randomized controlled trials comparing these two types of instrumentation would be useful to assess whether a benefit exists for PSI in the setting of primary TSA. Level of evidence: III.
Bibliography:http://www.cisejournal.org/journal/view.php?doi=10.5397/cise.2024.01095
ISSN:2383-8337
2288-8721
DOI:10.5397/cise.2024.01095