Introduction Argatroban, as a direct thrombin inhibitor, prolongs the clotting time. However, detection of clotting time is the base of routine fibrinogen assays, including Clauss method and derived method. The influences of argatroban on fibrinogen assays are still unclear. Methods Normal pooled pl...

Full description

Saved in:
Bibliographic Details
Published inInternational journal of laboratory hematology Vol. 39; no. 6; pp. 641 - 644
Main Authors Zhang, L., Yang, J., Zheng, X., Fan, Q., Zhang, Z.
Format Journal Article
LanguageEnglish
Published England Wiley Subscription Services, Inc 01.12.2017
Subjects
Online AccessGet full text
ISSN1751-5521
1751-553X
1751-553X
DOI10.1111/ijlh.12719

Cover

More Information
Summary:Introduction Argatroban, as a direct thrombin inhibitor, prolongs the clotting time. However, detection of clotting time is the base of routine fibrinogen assays, including Clauss method and derived method. The influences of argatroban on fibrinogen assays are still unclear. Methods Normal pooled plasma (NPP) from 20 healthy subjects was spiked with increasing argatroban concentrations (0‐3.2 μg/mL). Then the NPP samples were analyzed by five fibrinogen assays: HemosIL Fibrinogen‐C XL reagent (Clauss method) on ACL‐TOP; STA‐Fibrinogen reagent (Clauss method) on STA‐R Evolution; Siemens Thrombin reagent (Clauss method) on CS‐5100; SynthASil RecombiPlasTin 2G reagent (PT‐derived method) on ACL‐TOP; and N Antiserum to Human Fibrinogen reagent (NAHF, Immunoassay) on BN2 nephelometer analyzer. Results Argatroban had no influences on NAHF (P=.13). Compared with the NAHF, significant reduction was observed on Fibrinogen‐C XL (P<.01), while no influences were shown on the others (STA‐Fibrinogen: P=.41, Siemens Thrombin: P=.20, RecombiPlasTin 2G: P=.21) when activated partial thromboplastin time (APTT) ratio was no more than 3.0. As APTT ratio was increasing to 4.5, results from Clauss and PT‐derived methods were significantly lowered (STA‐Fibrinogen: P=.02, Siemens Thrombin: P<.01, Fibrinogen‐C XL: P<.01, RecombiPlasTin 2G: P<.01). Conclusion The influences of argatroban on fibrinogen assays differ greatly, clinicians should be aware of the influences of argatroban on the fibrinogen assays used on site to avoid misdiagnoses.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1751-5521
1751-553X
1751-553X
DOI:10.1111/ijlh.12719