Geometric and dosimetric verification of a recurrent neural network algorithm to compensate for respiratory motion using an articulated robotic couch

The purpose of this study is to evaluate the performance of a recurrent neural network (RNN)-based prediction algorithm to compensate for respiratory movement using an articulated robotic couch system. A prototype of a real-time respiratory motion compensation couch was built using an optical 3D mot...

Full description

Saved in:
Bibliographic Details
Published inJournal of the Korean Physical Society Vol. 78; no. 1; pp. 64 - 72
Main Authors Lee, Minsik, Cho, Min-Seok, Lee, Hoyeon, Jeong, Chiyoung, Kwak, Jungwon, Jung, Jinhong, Kim, Su Ssan, Yoon, Sang Min, Song, Si Yeol, Lee, Sang-wook, Kim, Jong Hoon, Choi, Eun Kyung, Cho, Seungryong, Cho, Byungchul
Format Journal Article
LanguageEnglish
Published Seoul The Korean Physical Society 01.01.2021
Springer Nature B.V
한국물리학회
Subjects
Online AccessGet full text
ISSN0374-4884
1976-8524
DOI10.1007/s40042-020-00013-x

Cover

More Information
Summary:The purpose of this study is to evaluate the performance of a recurrent neural network (RNN)-based prediction algorithm to compensate for respiratory movement using an articulated robotic couch system. A prototype of a real-time respiratory motion compensation couch was built using an optical 3D motion tracking system and a six-degree-of-freedom-articulated robotic system. To compensate for the system latency from motion detection to re-positioning of the system, RNN and double exponential smoothing (ES2) prediction algorithms were applied. Three aspects of performance were evaluated, simulation and experiments for geometric and dosimetric evaluations, using data from three liver and three lung patients who underwent stereotactic body radiotherapy. Overall, the RNN algorithm showed better geometric and dosimetric results than the other approaches. In simulation tests, RNN showed 82% average improvement ratio, compared with non-predicted results. In the geometric evaluation, RNN only showed average FWHM broadening of 1.5 mm, compared with the static case. In the dosimetric evaluation, RNN showed average gamma passing rates of 97.4 ± 1.0%, 89.0 ± 2.4% under the 3%/3 mm, 2%/2 mm respectively. It may be technically feasible to use the RNN prediction algorithm to compensate for respiratory motion with an articulated robotic couch system. The RNN algorithm could be widely used for motion compensation in patients undergoing radiotherapy.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:0374-4884
1976-8524
DOI:10.1007/s40042-020-00013-x