Tapered fiber Mach-Zehnder interferometer for simultaneous measurement of refractive index and temperature
An approach to achieve simultaneous measurement of refractive index and temperature is proposed by using a Mach-Zehnder interferometer realized on tapered single-mode optical fiber. The attenuation peak wavelength of the interference with specific order in the transmission spectrum shifts with chang...
Saved in:
Published in | Applied physics letters Vol. 94; no. 13; pp. 131110 - 131110-3 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
American Institute of Physics
30.03.2009
|
Online Access | Get full text |
ISSN | 0003-6951 1077-3118 |
DOI | 10.1063/1.3115029 |
Cover
Summary: | An approach to achieve simultaneous measurement of refractive index and temperature is proposed by using a Mach-Zehnder interferometer realized on tapered single-mode optical fiber. The attenuation peak wavelength of the interference with specific order in the transmission spectrum shifts with changes in the environmental refractive index and temperature. By utilizing
S
-band and
C
/
L
-band light sources, simultaneous discrimination of refractive index and temperature with the tapered fiber Mach-Zehnder interferometer is demonstrated with the corresponding sensitivities of −23.188 nm/RIU (refractive index unit) and
0.071
nm
/
°
C
, and −26.087 nm/RIU (blueshift) and
0.077
nm
/
°
C
(redshift) for the interference orders of 169 and 144, respectively. |
---|---|