Quantitative Analysis of Fe Content in Iron Ore via External Calibration in Conjunction with Internal Standardization Method Coupled with LIBS

The external calibration in conjunction with internal standardization(ECIS) coupled with laser-induced breakdown spectroscopic(LIBS) technique was proposed to perform the quantitative analysis of Fe content in iron ore The plasma temperature and the electron number density were calculated to prove t...

Full description

Saved in:
Bibliographic Details
Published inChemical research in Chinese universities Vol. 31; no. 1; pp. 107 - 111
Main Authors Sheng, Liwen, Zhang, Tianlong, Wang, Kang, Tang, Hongsheng, Li, Hua
Format Journal Article
LanguageEnglish
Published Heidelberg Jilin University and The Editorial Department of Chemical Research in Chinese Universities 01.02.2015
Institute of Analytical Science, College of Chemistry & Materials Science, Northwest University,Xi'an 710069, P.R.China%College of Science, Chang'an University, Xi'an 710064, P.R.China
Subjects
Online AccessGet full text
ISSN1005-9040
2210-3171
DOI10.1007/s40242-014-4318-1

Cover

More Information
Summary:The external calibration in conjunction with internal standardization(ECIS) coupled with laser-induced breakdown spectroscopic(LIBS) technique was proposed to perform the quantitative analysis of Fe content in iron ore The plasma temperature and the electron number density were calculated to prove that the plasma was under local thermodynamic equilibrium(LTE) conditions and to ensure that the integral intensities of Fe I lines were reasonable. In addition, the result of the quantitative analysis shows a content of (20.26±0.59)% by mass of Fe in the iron ore. It was determined by four calibration curves, drawn for four emission lines of Fe I(373.48, 373.71,404.58 and 438.35 nm) normalized by Mn I line, base on the ECIS method which can eliminate the influence of matrix effect and improve the accuracy of quantitative analysis, compared with the standard addition method. Both the results of these two analytical methods were compared with that listed in the Standard Substance Certificate. The percentage content of Fe in the same sample of iron ore by the ECIS method was (20.17±0.08)% by mass, which shows a good performance to analyze the Fe content of iron ore in combination with LIBS.
Bibliography:Laser-induced breakdown spectroscopy(LIBS); External calibration in conjunction with internal standardization(ECIS) method; Chemical analysis; Iron ore
The external calibration in conjunction with internal standardization(ECIS) coupled with laser-induced breakdown spectroscopic(LIBS) technique was proposed to perform the quantitative analysis of Fe content in iron ore The plasma temperature and the electron number density were calculated to prove that the plasma was under local thermodynamic equilibrium(LTE) conditions and to ensure that the integral intensities of Fe I lines were reasonable. In addition, the result of the quantitative analysis shows a content of (20.26±0.59)% by mass of Fe in the iron ore. It was determined by four calibration curves, drawn for four emission lines of Fe I(373.48, 373.71,404.58 and 438.35 nm) normalized by Mn I line, base on the ECIS method which can eliminate the influence of matrix effect and improve the accuracy of quantitative analysis, compared with the standard addition method. Both the results of these two analytical methods were compared with that listed in the Standard Substance Certificate. The percentage content of Fe in the same sample of iron ore by the ECIS method was (20.17±0.08)% by mass, which shows a good performance to analyze the Fe content of iron ore in combination with LIBS.
22-1183/06
ISSN:1005-9040
2210-3171
DOI:10.1007/s40242-014-4318-1