Comparison of convolutional-neural-networks-based method and LCModel on the quantification of in vivo magnetic resonance spectroscopy
Background Quantification of metabolites concentrations in institutional unit (IU) is important for inter-subject and long-term comparisons in the applications of magnetic resonance spectroscopy (MRS). Recently, deep learning (DL) algorithms have found a variety of applications on the process of MRS...
Saved in:
| Published in | Magma (New York, N.Y.) Vol. 37; no. 3; pp. 477 - 489 |
|---|---|
| Main Authors | , , |
| Format | Journal Article |
| Language | English |
| Published |
Cham
Springer International Publishing
01.07.2024
|
| Subjects | |
| Online Access | Get full text |
| ISSN | 1352-8661 1352-8661 |
| DOI | 10.1007/s10334-023-01120-z |
Cover
| Summary: | Background
Quantification of metabolites concentrations in institutional unit (IU) is important for inter-subject and long-term comparisons in the applications of magnetic resonance spectroscopy (MRS). Recently, deep learning (DL) algorithms have found a variety of applications on the process of MRS data. A quantification strategy compatible to DL base MRS spectral processing method is, therefore, useful.
Materials and methods
This study aims to investigate whether metabolite concentrations quantified using a convolutional neural network (CNN) based method, coupled with a scaling procedure that normalizes spectral signals for CNN input and linear regression, can effectively reflect variations in metabolite concentrations in IU across different brain regions with varying signal-to-noise ratios (SNR) and linewidths (LW). An error index based on standard error (SE) is proposed to indicate the confidence levels associated with metabolite predictions. In vivo MRS spectra were acquired from three brain regions of 43 subjects using a 3T system.
Results
The metabolite concentrations in IU of five major metabolites, quantified using CNN and LCModel, exhibit similar ranges with Pearson’s correlation coefficients ranging from 0.24 to 0.78. The SE of the metabolites shows a positive correlation with Cramer-Rao lower bound (CRLB) (r=0.46) and absolute CRLB (r=0.81), calculated by multiplying CRLBs with the quantified metabolite content.
Conclusion
In conclusion, the CNN based method with the proposed scaling procedures can be employed to quantify in vivo MRS spectra and derive metabolites concentrations in IU. The SE can be used as error index, indicating predicted uncertainties for metabolites and sharing information similar to the absolute CRLB. |
|---|---|
| Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
| ISSN: | 1352-8661 1352-8661 |
| DOI: | 10.1007/s10334-023-01120-z |