SR-Unet: A Super-Resolution Algorithm for Ion Trap Mass Spectrometers Based on the Deep Neural Network
The mass spectrometer is an important tool for modern chemical analysis and detection. Especially, the emergence of miniature mass spectrometers has provided new tools for field analysis and detection. The resolution of a mass spectrometer reflects the ability of the instrument to discriminate betwe...
Saved in:
| Published in | Analytical chemistry (Washington) Vol. 95; no. 47; pp. 17407 - 17415 |
|---|---|
| Main Authors | , , , , , , |
| Format | Journal Article |
| Language | English |
| Published |
Washington
American Chemical Society
28.11.2023
|
| Subjects | |
| Online Access | Get full text |
| ISSN | 0003-2700 1520-6882 1520-6882 |
| DOI | 10.1021/acs.analchem.3c04172 |
Cover
| Summary: | The mass spectrometer is an important tool for modern chemical analysis and detection. Especially, the emergence of miniature mass spectrometers has provided new tools for field analysis and detection. The resolution of a mass spectrometer reflects the ability of the instrument to discriminate between adjacent mass-to-charge ratio ions, and the higher the resolution, the better the discrimination of complex mixtures. Quadrupole ion traps are generally considered as a low-resolution mass spectrometry method, but they have gained wide attention and development in recent years because of their suitability for miniaturization and high qualitative capability. For an ion trap mass spectrometer, the mass sensitivity and resolution can be mutually constrained and need to be balanced by setting an appropriate scanning speed. In this study, a super-resolution U-net algorithm (SR-Unet) is proposed for ion trap mass spectrometry, which can estimate the possible ions from the overlapping ion peaks of low-resolution spectra and improve the equivalent resolution while ensuring sufficient sensitivity and analysis speed of the instrument. By determining the mass spectra of a linear ion trap mass spectrometer (LTQ XL) in Turbo and Normal scan modes, the same unit mass resolution as that at a scan speed of 16,667 Da/s was successfully obtained at 125,000 Da/s. Also, the experiments demonstrated that the algorithm is capable of the mass-to-charge ratio and instrument migration. SR-Unet can be migrated and applied to a miniature mass spectrometer for cruise detection of volatile organic compounds (VOCs), and the identification of VOC species in Photochemical Assessment Monitoring Stations (PAMS) was improved from 31 to 50 species with the same monitoring and analysis speed requirement. Further, super-unit mass resolution peptide detection was achieved on a miniature mass spectrometer with the help of the SR-Unet algorithm, which reduced the full width at half-maxima (FWHM) of bradykinin divalent ions (m/z 531) from 0.35 to 0.15 Da at a scan speed of 375 Da/s and improved the equivalent resolution to 3540. The proposed method provides a new idea to enhance the field mixture detection capability of miniature ion trap mass spectrometers. |
|---|---|
| Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
| ISSN: | 0003-2700 1520-6882 1520-6882 |
| DOI: | 10.1021/acs.analchem.3c04172 |