Early and Mid-Term Outcomes of Transcatheter Aortic Valve Replacement Using the New Generation Self-Expanding Corevalve Evolut R Device

To assess early and mid-term efficacy of transcatheter aortic valve replacement (TAVR) using the new-generation CoreValve Evolut R (Medtronic Inc., Galway, Ireland). This is a prospective, single-center study. All consecutive patients undergoing TAVR with 23-, 26-, 29-, 34-mm Evolut R valve were incl...

Full description

Saved in:
Bibliographic Details
Published inStructural heart (Online) Vol. 2; no. 3; pp. 229 - 234
Main Authors Todaro, Denise, Barbanti, Marco, Picci, Andrea, Costa, Giuliano, Di Simone, Emanuela, Gulino, Simona, Capranzano, Piera, Pilato, Gerlando, La Spina, Ketty, Deste, Wanda, Indelicato, Antonino, Giannazzo, Daniela, D’Arrigo, Paolo, Portelli, Maria Cristina, Capodanno, Davide, Immè, Sebastiano, Tamburino, Claudia, Patanè, Martina, Sgroi, Carmelo, Tamburino, Corrado
Format Journal Article
LanguageEnglish
Published Elsevier Inc 04.05.2018
Taylor & Francis
Subjects
Online AccessGet full text
ISSN2474-8706
2474-8714
DOI10.1080/24748706.2018.1440097

Cover

More Information
Summary:To assess early and mid-term efficacy of transcatheter aortic valve replacement (TAVR) using the new-generation CoreValve Evolut R (Medtronic Inc., Galway, Ireland). This is a prospective, single-center study. All consecutive patients undergoing TAVR with 23-, 26-, 29-, 34-mm Evolut R valve were included. In a secondary analysis, patients undergoing Evolut R implantation were compared using the propensity score method with a historical cohort of patients who underwent CoreValve implantation in our institution. From March 2015 to September 2017, a total of 320 patients with a median age of 81.1 years (IQR 77–84) and mean STS score of 4.9 ± 3.1% were treated. Device success was obtained in 300 patients (93.8%). Effective recapture and repositioning of the valve due to initial suboptimal deployment was accomplished in 40 patients (12.5%). Post-TAVR transthoracic echocardiogram showed a reduction in mean gradient from 49.1 ± 18.2 mmHg to 7.6 ± 0.4 mmHg (p < 0.001). Moderate paravalvular regurgitation (PVR) was observed in 4.2% patients. No patient had severe PVR. At 30-day, all-cause and cardiovascular mortality rates were 2.2% and 1.9%, respectively; disabling stroke occurred in 5 patients (1.6%). Life-threatening and major bleeding occurred in 16 (5.0%) and 42 (13.1%) patients, respectively. Pacemaker implantation rate was 12.6%. Compared with the CoreValve, Evolut R use was associated with higher device success (92.8% vs. 79.7%, p < 0.001) and lower rates of moderate or severe PVR (2.1% vs. 14.4%, p < 0.001), minor vascular complications (4.9% vs. 14.5%, p < 0.001), and pacemaker implantation (13.5% vs. 21.0%, p = 0.026). In this prospective, single-center study, TAVR using the new-generation self-expanding Evolut R system, was associated with high device success rate, excellent hemodynamics, and low early complications rates.
ISSN:2474-8706
2474-8714
DOI:10.1080/24748706.2018.1440097