Thermal analysis of the cryostat feed through for the ITER Tokamak TF feeder

In Tokamaks,the toroidal field (TF) coil feeder is an important component that is used to supply the cryogens and electrical power for the TF coils.As a part of the TF feeder,the cryostat-feed through (CFT) is subject to low temperatures of 9 and 80 K inside and room temperature of 300 K outside.Bas...

Full description

Saved in:
Bibliographic Details
Published inPlasma science & technology Vol. 19; no. 4; pp. 99 - 106
Main Author 张善文 宋云涛 陆坤 王忠伟 张剑峰 秦永法
Format Journal Article
LanguageEnglish
Published IOP Publishing 01.04.2017
Subjects
Online AccessGet full text
ISSN1009-0630
1009-0630
DOI10.1088/2058-6272/aa57ec

Cover

More Information
Summary:In Tokamaks,the toroidal field (TF) coil feeder is an important component that is used to supply the cryogens and electrical power for the TF coils.As a part of the TF feeder,the cryostat-feed through (CFT) is subject to low temperatures of 9 and 80 K inside and room temperature of 300 K outside.Based on the features of the International Thermonuclear Experimental Reactor TF feeder,the thermal performance of the CFT under the nominal conditions is studied.Taking into account the conductive,convective and radiation heat transfer,the finite element model of the CFT is built.Transient thermal analysis is performed to determine the temperatures of the CFT on the 9th day of cooldown.The model is assessed by comparing the cooling curves of the CFT after 9 days.If the simulation and experimental results are the same,the finite element model can be considered as calibrated.The model predicts that the cooling time will be approximately 26 days and the temperature distribution and heat load of the main components are obtained when the CFT reaches thermal equilibrium.This study provides a valid quantitative characterization of the CFT design.
Bibliography:In Tokamaks,the toroidal field (TF) coil feeder is an important component that is used to supply the cryogens and electrical power for the TF coils.As a part of the TF feeder,the cryostat-feed through (CFT) is subject to low temperatures of 9 and 80 K inside and room temperature of 300 K outside.Based on the features of the International Thermonuclear Experimental Reactor TF feeder,the thermal performance of the CFT under the nominal conditions is studied.Taking into account the conductive,convective and radiation heat transfer,the finite element model of the CFT is built.Transient thermal analysis is performed to determine the temperatures of the CFT on the 9th day of cooldown.The model is assessed by comparing the cooling curves of the CFT after 9 days.If the simulation and experimental results are the same,the finite element model can be considered as calibrated.The model predicts that the cooling time will be approximately 26 days and the temperature distribution and heat load of the main components are obtained when the CFT reaches thermal equilibrium.This study provides a valid quantitative characterization of the CFT design.
thermal analysis, tokamak, TF feeder, CFT
Shanwen ZHANG1,3, Yuntao SONG2, Kun LU2, Zhongwei WANG2, Jianfeng ZHANG and Yongfa QIN1(1 College of Mechanical Engineering Yangzhou University, Yangzhou 225127, People's Republic of China 2 Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 200031, People's Republic of China)