A Novel Technique for Non-Invasive Measurement of Human Blood Component Levels From Fingertip Video Using DNN Based Models

Blood components such as hemoglobin, glucose, creatinine measuring are essential for monitoring one's health condition. The current blood component measurement approaches still depend on invasive techniques that are painful, and uncomfortable for the patients. To facilitate measurement at home,...

Full description

Saved in:
Bibliographic Details
Published inIEEE access Vol. 9; pp. 19025 - 19042
Main Authors Haque, Md. Rezwanul, Raju, S. M. Taslim Uddin, Golap, Md. Asaf-Uddowla, Hashem, M. M. A.
Format Journal Article
LanguageEnglish
Published Piscataway IEEE 2021
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text
ISSN2169-3536
2169-3536
DOI10.1109/ACCESS.2021.3054236

Cover

More Information
Summary:Blood components such as hemoglobin, glucose, creatinine measuring are essential for monitoring one's health condition. The current blood component measurement approaches still depend on invasive techniques that are painful, and uncomfortable for the patients. To facilitate measurement at home, we proposed a novel non-invasive technique to measure blood hemoglobin, glucose, and creatinine level based on PPG signal using Deep Neural Networks (DNN). Fingertip videos from 93 subjects have been collected using a smartphone. The PPG signal is generated from each video, and 46 characteristic features are then extracted from the PPG signal, its derivatives (1 st and 2 nd ) and from Fourier analysis. Additionally, age and gender are also included to feature because of the significant effects on hemoglobin, glucose, and creatinine. A correlation-based feature selection (CFS) using genetic algorithms (GA) has been used to select the optimal features to avoid redundancy and over-fitting. Finally, DNN based models have been developed to estimate the blood Hemoglobin (Hb), Glucose (Gl), and Creatinine (Cr) levels from the selected features. The approach provides the best-estimated accuracy of R 2 = 0.922 for Hb, R 2 = 0.902 for Gl, and R 2 = 0.969 for Cr. Experimental aftermaths show that the proposed method is a suitable technique to be used clinically to measure human blood component levels without taking blood samples. This paper also reveals that smartphone-based PPG signal has a great potential to measure the different blood components.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:2169-3536
2169-3536
DOI:10.1109/ACCESS.2021.3054236