Simulating indoor inorganic aerosols of outdoor origin with the inorganic aerosol thermodynamic equilibrium model ISORROPIA

Outdoor aerosols can transform and have their composition altered upon transport indoors. Herein, IMAGES, a platform that simulates indoor organic aerosol with the 2‐dimensional volatility basis set (2D‐VBS), was extended to incorporate the inorganic aerosol thermodynamic equilibrium model, ISORROPI...

Full description

Saved in:
Bibliographic Details
Published inIndoor air Vol. 32; no. 7; pp. e13075 - n/a
Main Authors Berman, Bryan C., Cummings, Bryan E., Avery, Anita M., DeCarlo, Peter F., Capps, Shannon L., Waring, Michael S.
Format Journal Article
LanguageEnglish
Published Malden John Wiley & Sons, Inc 01.07.2022
Subjects
Online AccessGet full text
ISSN0905-6947
1600-0668
1600-0668
DOI10.1111/ina.13075

Cover

More Information
Summary:Outdoor aerosols can transform and have their composition altered upon transport indoors. Herein, IMAGES, a platform that simulates indoor organic aerosol with the 2‐dimensional volatility basis set (2D‐VBS), was extended to incorporate the inorganic aerosol thermodynamic equilibrium model, ISORROPIA. The model performance was evaluated by comparing aerosol component predictions to indoor measurements from an aerosol mass spectrometer taken during the summer and winter seasons. Since ammonia was not measured in the validation dataset, outdoor ammonia was estimated from aerosol measurements using a novel pH‐based algorithm, while nitric acid was held constant. Modeled indoor ammonia sources included temperature‐based occupant and surface emissions. Sensitivity to the nitric acid indoor surface deposition rate βg,HNO3,g was explored by varying it in model runs, which did not affect modeled sulfate due to its non‐volatile nature, though the fitting of a filter efficiency was required for good correlations of modeled sulfate with measurements in both seasons. Modeled summertime nitrate well‐matched measured observations when βg,HNO3,g=2.75h−1, but wintertime comparisons were poor, possibly due to missing thermodynamic processes within the heating, ventilating, and air‐conditioning (HVAC) system. Ammonium was consistently overpredicted, potentially due to neglecting thirdhand smoke impacts observed in the field campaign, as well as HVAC impacts.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0905-6947
1600-0668
1600-0668
DOI:10.1111/ina.13075