Protection coordination scheme for directional overcurrent relays considering change in network topology and OLTC tap position
•Overcurrent protection coordination scheme of power networks running under N−1 contingencies.•Consideration of impacts of OLTC taps on the overcurrent protection coordination scheme.•An efficient constraint reduction strategy to reduce the number of primary-backup relay pairs.•Two-phase interior-po...
        Saved in:
      
    
          | Published in | Electric power systems research Vol. 185; p. 106395 | 
|---|---|
| Main Authors | , , | 
| Format | Journal Article | 
| Language | English | 
| Published | 
        Amsterdam
          Elsevier B.V
    
        01.08.2020
     Elsevier Science Ltd  | 
| Subjects | |
| Online Access | Get full text | 
| ISSN | 0378-7796 1873-2046  | 
| DOI | 10.1016/j.epsr.2020.106395 | 
Cover
| Summary: | •Overcurrent protection coordination scheme of power networks running under N−1 contingencies.•Consideration of impacts of OLTC taps on the overcurrent protection coordination scheme.•An efficient constraint reduction strategy to reduce the number of primary-backup relay pairs.•Two-phase interior-point method-based algorithm to solve the protection coordination problem.•Analysis of overcurrent protection scheme of single network topology and contingencies network topologies.
This paper proposes a robust protection coordination scheme of directional overcurrent relays (DOCRs) for multiple network topologies in the presence of on-load tap changers (OLTCs). The robust protection coordination scheme provides single settings of DOCRs which will be valid for all N−1 contingencies created after outage of a line, transformer or generator. An efficient constraint reduction strategy is introduced to reduce the number of coordination constraints caused by consideration of multiple topologies. The impact of tap positions of the OLTCs has been incorporated in the required steady-state and short-circuit current calculations. The robust protection coordination scheme has been posed as an optimization problem and solved using an interior point method based algorithm. The feasibility and the effectiveness of the proposed formulation and solution algorithm has been demonstrated on the IEEE 14-bus power system network. | 
|---|---|
| Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14  | 
| ISSN: | 0378-7796 1873-2046  | 
| DOI: | 10.1016/j.epsr.2020.106395 |