Dynamic characteristics test of safety class cable for nuclear power plants

The purpose of this dynamic characteristic test is to verify that the damping ratio used in the seismic analysis of the battery connection cable that constantly stores the emergency power of a nuclear power plant is 5 % or higher, and to confirm that the structural integrity of the cable supplied to...

Full description

Saved in:
Bibliographic Details
Published inNuclear engineering and technology Vol. 57; no. 8; p. 103557
Main Authors Son, Jung-Dae, Kim, Jae-Hong, Song, Kum-Young, Kim, Jung-Han
Format Journal Article
LanguageEnglish
Published Elsevier B.V 01.08.2025
Elsevier
한국원자력학회
Subjects
Online AccessGet full text
ISSN1738-5733
2234-358X
DOI10.1016/j.net.2025.103557

Cover

More Information
Summary:The purpose of this dynamic characteristic test is to verify that the damping ratio used in the seismic analysis of the battery connection cable that constantly stores the emergency power of a nuclear power plant is 5 % or higher, and to confirm that the structural integrity of the cable supplied to the nuclear power plant is safe. The dynamic characteristic test method of the cable was performed using the same sample as the cable installed in the battery for a nuclear power plant, and the dynamic characteristic test was performed with reference to the Korean standard (KS B ISO 7626 [1, 2, 3], KS I ISO 10846 [4], KS M 6665 [5]). The test results proved that the damping ratio of 5 % applied to the seismic analysis of cables so far is reliable.