Is C1 lateral mass screw placement safe for the Chinese, Indians, and Malays? An analysis of 180 computed tomography scans

Introduction: C1 lateral mass (C1LM) screw is a common procedure in spine surgery. However, related studies are lacking in Asia. We aim to determine the safety of C1LM screw for the Chinese, Indians, and Malays. Methods: Three-dimensional computed tomographies of 180 subjects (60 from each ethnic) w...

Full description

Saved in:
Bibliographic Details
Published inJournal of orthopaedic surgery (Hong Kong) Vol. 25; no. 1; p. 2309499017692683
Main Authors Lee, CK, Tan, TS, Chan, CYW, Kwan, MK
Format Journal Article
LanguageEnglish
Published London, England SAGE Publications 01.01.2017
Sage Publications Ltd
SAGE Publishing
Subjects
Online AccessGet full text
ISSN1022-5536
2309-4990
2309-4990
DOI10.1177/2309499017692683

Cover

More Information
Summary:Introduction: C1 lateral mass (C1LM) screw is a common procedure in spine surgery. However, related studies are lacking in Asia. We aim to determine the safety of C1LM screw for the Chinese, Indians, and Malays. Methods: Three-dimensional computed tomographies of 180 subjects (60 from each ethnic) were analyzed. The length and angulations of C1LM screw and the location of internal carotid artery (ICA) in relation to C1LM were assessed and classified according to the classification by Murakami et al. The incidence of ponticulus posticus (PP) was determined and the differences among the population of these three ethnics were recorded. Results: The average base length was 8.5 ± 1.4 mm. The lengths within the lateral mass were between 14.7 ± 1.6 mm and 21.7 ± 2.3 mm. The prevalence of PP was 8.3%. 55.3% (199) of ICA were located in zone 0, 38.3% (138) in zone 1-1, 6.4% (23) in zone 1-2, and none in zone 1-3 and zone 2. The average angulation from the entry point to the ICA was 8.5° ± 6.4° laterally. The mean distance of ICA from C1 anterior cortex was 3.7 ± 1.7 mm (range: 0.6∼11.3). There was no difference in distribution of ICA in zone 1 among the three population (Chinese–47%, Indians–61%, and Malays–53%; p > 0.05). Conclusions: No ICA is located medial to the entry point of C1LM screw. If bicortical purchase of C1LM screw is needed, screw protrusion of less than 3 mm or medially angulated is safe for ICA. The incidence of PP is 8.3% with higher prevalence among the Indian population.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1022-5536
2309-4990
2309-4990
DOI:10.1177/2309499017692683