Simultaneous extraction of Cu2+ and Cd2+ ions in water, wastewater, and food samples using solvent-terminated dispersive liquid–liquid microextraction: optimization by multiobjective evolutionary algorithm based on decomposition
Solvent-terminated dispersive liquid-liquid microextraction (ST-DLLME) as a simple, fast, and low-cost technique was developed for simultaneous extraction of Cd 2+ and Cu 2+ ions in aqueous solutions. Multiobjective evolutionary algorithm based on decomposition with the aid of artificial neural netw...
Saved in:
| Published in | Environmental monitoring and assessment Vol. 191; no. 5; p. 287 |
|---|---|
| Main Authors | , , , |
| Format | Journal Article |
| Language | English |
| Published |
Cham
Springer International Publishing
01.05.2019
Springer Nature B.V |
| Subjects | |
| Online Access | Get full text |
| ISSN | 0167-6369 1573-2959 1573-2959 |
| DOI | 10.1007/s10661-019-7383-6 |
Cover
| Summary: | Solvent-terminated dispersive liquid-liquid microextraction (ST-DLLME) as a simple, fast, and low-cost technique was developed for simultaneous extraction of Cd
2+
and Cu
2+
ions in aqueous solutions. Multiobjective evolutionary algorithm based on decomposition with the aid of artificial neural networks (ANN–MOEA/D) was used for the first time in chemistry, environment, and food sciences to optimize several independent variables affecting the extraction efficiency, including disperser volume and extraction solvent volume, pH, and salt addition. To perform the ST-DLLME operations, xylene, methanol, and dithizone were utilized as an extraction solvent, disperser solvent, and chelating agent, respectively. Non-dominated sorting genetic algorithm versions II and III (NSGA II and NSGA III) as multiobjective metaheuristic algorithms and in addition central composite design (CCD) were studied as comparable optimization methods. A comparison of results from these techniques revealed that ANN-MOEA/D model was the best optimization technique owing to its highest efficiency (97.6% for Cd
2+
and 98.3% for Cu
2+
). Under optimal conditions obtained by ANN-MOEAD, the detection limit (S/N = 3), the quantitation limit(S/N = 10), and the linear range for Cu
2+
were 0.05, 0.15, and 0.15–1000 μg L
−1
, respectively, and for Cd
2+
were 0.07, 0.21, and 0.21–750 μg L
−1
, respectively. The real sample recoveries at a spiking level of 0.05, 0.1, and 0.3 mg L
−1
of Cu
2+
and Cd
2+
ions under the optimal conditions obtained by ANN–MOEA/D ranged from 94.8 to 105%. |
|---|---|
| Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
| ISSN: | 0167-6369 1573-2959 1573-2959 |
| DOI: | 10.1007/s10661-019-7383-6 |