ECRH Launcher for Four-Beam Injection on HL-2A Tokamak
An Electron Cyclotron Resonance Heating (ECRH) launcher for four-beam injection has been installed on the HL-2A tokamak and used in plasma heating experiments. By the launcher, four EC wave beams can be injected into the tokamak through a φ350 mm port, which are generated from 2 sets of 68 GHz/1 s a...
        Saved in:
      
    
          | Published in | Plasma science & technology Vol. 15; no. 5; pp. 476 - 479 | 
|---|---|
| Main Author | |
| Format | Journal Article | 
| Language | English | 
| Published | 
          
        01.05.2013
     | 
| Subjects | |
| Online Access | Get full text | 
| ISSN | 1009-0630 | 
| DOI | 10.1088/1009-0630/15/5/16 | 
Cover
| Summary: | An Electron Cyclotron Resonance Heating (ECRH) launcher for four-beam injection has been installed on the HL-2A tokamak and used in plasma heating experiments. By the launcher, four EC wave beams can be injected into the tokamak through a φ350 mm port, which are generated from 2 sets of 68 GHz/1 s and 2 sets of 68 GHz/1.5 s gyrotron tubes manufactured by GYCOM, with maximum output power of 500 kW for each. In this paper, the properties of the EC beam in the launcher and plasma are presented: at the centre of the cross section of the tokamak, the beam radius is 31.7 mm; thermal analysis of a 3D model indicates that the peak temperature increase would be only 30 o C at the mirror surface for a 500 kW/1 s pulse; ray-tracing calculation predicts satisfactory power deposition. In the plasma experiment, six beams including four beams from this launcher and two from another launcher have been injected simultaneously. Besides, obtaining ELM-y H-mode discharges, the ECRH system shows reliability and stability of the launcher functions. | 
|---|---|
| Bibliography: | An Electron Cyclotron Resonance Heating (ECRH) launcher for four-beam injection has been installed on the HL-2A tokamak and used in plasma heating experiments. By the launcher, four EC wave beams can be injected into the tokamak through a φ350 mm port, which are generated from 2 sets of 68 GHz/1 s and 2 sets of 68 GHz/1.5 s gyrotron tubes manufactured by GYCOM, with maximum output power of 500 kW for each. In this paper, the properties of the EC beam in the launcher and plasma are presented: at the centre of the cross section of the tokamak, the beam radius is 31.7 mm; thermal analysis of a 3D model indicates that the peak temperature increase would be only 30 o C at the mirror surface for a 500 kW/1 s pulse; ray-tracing calculation predicts satisfactory power deposition. In the plasma experiment, six beams including four beams from this launcher and two from another launcher have been injected simultaneously. Besides, obtaining ELM-y H-mode discharges, the ECRH system shows reliability and stability of the launcher functions. ECRH, launcher, Gaussian beam, HL-2A 34-1187/TL WANG Chao , ZHOU Jun , HUANG Mei , WANG He , CHEN Gangyu , RAO Jun (Southwestern Institute of Physics, Chengdu 610041, China) ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23  | 
| ISSN: | 1009-0630 | 
| DOI: | 10.1088/1009-0630/15/5/16 |