Nanowire-Based Sensor Array for Detection of Cross-Sensitive Gases Using PCA and Machine Learning Algorithms

In this work, a gas sensor array has been designed and developed comprising of Pt, Cu and Ag decorated TiO 2 and ZnO functionalized GaN nanowires using industry standard top-down fabrication approach. The receptor metal/metal-oxide combinations within the array have been determined from our prior mo...

Full description

Saved in:
Bibliographic Details
Published inIEEE sensors journal Vol. 20; no. 11; pp. 6020 - 6028
Main Authors Khan, Md Ashfaque Hossain, Thomson, Brian, Debnath, Ratan, Motayed, Abhishek, Rao, Mulpuri V.
Format Journal Article
LanguageEnglish
Published New York IEEE 01.06.2020
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text
ISSN1530-437X
1558-1748
DOI10.1109/JSEN.2020.2972542

Cover

More Information
Summary:In this work, a gas sensor array has been designed and developed comprising of Pt, Cu and Ag decorated TiO 2 and ZnO functionalized GaN nanowires using industry standard top-down fabrication approach. The receptor metal/metal-oxide combinations within the array have been determined from our prior molecular simulation results using first principle calculations based on density functional theory (DFT). The gas sensing data was collected for both singular and mixture of NO 2 , ethanol, SO 2 and H 2 in presence of H 2 O and O 2 gases under UV light at room temperature. Each gas produced a unique response pattern across the sensors within the array by which precise identification of cross-sensitive gases is possible. After pre-processing of raw data, unsupervised principal component analysis (PCA) technique was applied on the array response. It is found that, each analyte gas forms a separate cluster in the score plot for all the target gases and their mixtures, indicating a clear discrimination among them. Then, four supervised machine learning algorithms such as- Decision Tree, Support Vector Machine (SVM), Naive Bayes (kernel) and k-Nearest Neighbor (k-NN) were trained and optimized using their significant parameters with our array dataset for the classification of gas type. Results indicate that the optimized SVM and NB classifier models exhibited 100% classification accuracy on test dataset. Practical applicability of the considered algorithms has been discussed as well. Moreover, this array device works at room-temperature using very low power and low-cost UV light-emitting diode (LED) as compared to high power consuming commercially available metal-oxide sensors.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:1530-437X
1558-1748
DOI:10.1109/JSEN.2020.2972542