Model based noise correction enhances the accuracy of pancreatic CT perfusion blood flow measurements

A model based noise correction algorithm was developed to improve the accuracy of CT perfusion (CTp) blood flow (BF) measurements affected by image noise. The algorithm used tissue attenuation curves (TACs), generated by convolving an impulse response function (IRF) with an arterial input function (...

Full description

Saved in:
Bibliographic Details
Published inScientific reports Vol. 15; no. 1; pp. 37165 - 13
Main Authors Vats, Neha, Mayer, Philipp, Kortes, Franziska, Klauß, Miriam, Grenacher, Lars, Kauczor, Hans-Ulrich, Stiller, Wolfram, Skornitzke, Stephan
Format Journal Article
LanguageEnglish
Published London Nature Publishing Group UK 23.10.2025
Nature Publishing Group
Nature Portfolio
Subjects
Online AccessGet full text
ISSN2045-2322
2045-2322
DOI10.1038/s41598-025-24482-x

Cover

More Information
Summary:A model based noise correction algorithm was developed to improve the accuracy of CT perfusion (CTp) blood flow (BF) measurements affected by image noise. The algorithm used tissue attenuation curves (TACs), generated by convolving an impulse response function (IRF) with an arterial input function (AIF) averaged from 59 patient datasets. Gaussian noise was introduced to simulate noise, and BF was measured using deconvolution. The algorithm iteratively compared BF without added noise against noise-impacted BF to estimate ground-truth BF (GTBF). Performance was evaluated with digital perfusion phantoms (DPPs) for GTBF values of 5–420 ml/100 ml/min and added noise (standard deviation 25 HU), measuring absolute difference from GTBF and contrast-to-noise ratio (CNR). For clinical evaluation, CTp data from 14 pancreatic ductal adenocarcinoma (PDAC) patients was used. For DPPs, noise-impacted and noise-corrected BF were 140 ± 111 ml/100 ml/min and 131 ± 125 ml/100 ml/min, compared to GTBF of 131 ± 127 ml/100 ml/min. Post-correction, the absolute difference reduced from 18.8 to 3.6 ml/100 ml/min, with CNR improving from 2.52 to 2.66. In clinical datasets, BF for parenchyma shifted from 148 ± 50.8 to 84.1 ± 96.9 ml/100 ml/min, and for PDAC, from 45.8 ± 20.3 to 13.3 ± 18.7 ml/100 ml/min. The algorithm reduced noise impact, improving BF accuracy and CNR, with potential for lower-dose CT without compromising diagnostic quality.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:2045-2322
2045-2322