Capacitive coupling leading to electrical skin burn injury during laparoscopic surgery

Purpose: Trocar-site burns occurring during laparoscopic surgery have been reported in various cases, and several efforts to reduce them are underway. This study aimed to analyze the effect of capacitive coupling on trocar site by observing electrical and histological changes for electrical skin bur...

Full description

Saved in:
Bibliographic Details
Published inJournal of minimally invasive surgery Vol. 25; no. 3; pp. 106 - 111
Main Authors Kim, Woo Jun, Son, Gyung Mo, Lee, In Young, Yun, Sung Uk, Jeon, Gye Rok, Shin, Dong-Hoon, Kwon, Myung Sook, Kwak, Jae Yeong, Baek, Kwang-Ryul
Format Journal Article
LanguageEnglish
Published The Korean Society of Endoscopic and Laparoscopic Surgeons 15.09.2022
The Korean Society of Endo-Laparoscopic & Robotic Surgery
대한내시경로봇외과학회
Subjects
Online AccessGet full text
ISSN2234-778X
2234-5248
DOI10.7602/jmis.2022.25.3.106

Cover

More Information
Summary:Purpose: Trocar-site burns occurring during laparoscopic surgery have been reported in various cases, and several efforts to reduce them are underway. This study aimed to analyze the effect of capacitive coupling on trocar site by observing electrical and histological changes for electrical skin burn injury.Methods : To measure the electrical changes relating to capacitive coupling, the temperature, current, voltage, and impedance around the trocar were measured when an open circuit and a closed circuit were formed using insulation intact instruments and repeated after insulation failure. After the experiment, the tissue around the trocar was collected, and microscopic examination was performed.Results : When open circuits were formed with the intact insulation, the impedance was significantly reduced compared to the cases of closed circuits (142.0 Ω vs. 109.3 Ω, p = 0.040). When the power was 30 W and there was insulation failure, no significant difference was measured between the open circuit and the closed circuit (147.7 Ω vs. 130.7 Ω, p = 0.103). Collagen hyalinization, nuclear fragmentation, and coagulation necrosis suggesting burns were observed in the skin biopsy at the trocar insertion site.Conclusion : This study demonstrated that even with a plastic trocar and electrosurgical instruments that have intact insulation, if an open circuit is formed, capacitive coupling increases, and trocar-site burn can occur. When using electrocautery, careful manipulation must be taken to avoid creating an open circuit to prevent capacitive coupling related to electrical skin burn.
ISSN:2234-778X
2234-5248
DOI:10.7602/jmis.2022.25.3.106