Evaluation of transient measurements of thermophysical parameters using Finite Elements Method

The transient plane source (TPS) method was used to measure the thermal diffusivity and conductivity of silica glass and polymethyl methacrylate (PMMA). The results were evaluated by an analytical model and also by a numerical model created by the finite elements method (FEM). The results of both mo...

Full description

Saved in:
Bibliographic Details
Published inJournal of physics. Conference series Vol. 2628; no. 1; pp. 12020 - 12024
Main Author Malinarič, S
Format Journal Article
LanguageEnglish
Published Bristol IOP Publishing 01.10.2023
Subjects
Online AccessGet full text
ISSN1742-6588
1742-6596
1742-6596
DOI10.1088/1742-6596/2628/1/012020

Cover

More Information
Summary:The transient plane source (TPS) method was used to measure the thermal diffusivity and conductivity of silica glass and polymethyl methacrylate (PMMA). The results were evaluated by an analytical model and also by a numerical model created by the finite elements method (FEM). The results of both models and both materials were compared, and the difference was less than 0.4%.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:1742-6588
1742-6596
1742-6596
DOI:10.1088/1742-6596/2628/1/012020