Evaluation of transient measurements of thermophysical parameters using Finite Elements Method
The transient plane source (TPS) method was used to measure the thermal diffusivity and conductivity of silica glass and polymethyl methacrylate (PMMA). The results were evaluated by an analytical model and also by a numerical model created by the finite elements method (FEM). The results of both mo...
Saved in:
| Published in | Journal of physics. Conference series Vol. 2628; no. 1; pp. 12020 - 12024 |
|---|---|
| Main Author | |
| Format | Journal Article |
| Language | English |
| Published |
Bristol
IOP Publishing
01.10.2023
|
| Subjects | |
| Online Access | Get full text |
| ISSN | 1742-6588 1742-6596 1742-6596 |
| DOI | 10.1088/1742-6596/2628/1/012020 |
Cover
| Summary: | The transient plane source (TPS) method was used to measure the thermal diffusivity and conductivity of silica glass and polymethyl methacrylate (PMMA). The results were evaluated by an analytical model and also by a numerical model created by the finite elements method (FEM). The results of both models and both materials were compared, and the difference was less than 0.4%. |
|---|---|
| Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 |
| ISSN: | 1742-6588 1742-6596 1742-6596 |
| DOI: | 10.1088/1742-6596/2628/1/012020 |