Simultaneous Determination of Saponins in Radix Glycyrrhizae, Notoginseng and Ginseng by High Performance Liquid Chromatography

To establish a method for determining five saponins(notoginsenoside R1, ginsenoside Rg1, ginsenoside Re, ginsenoside Rb1 and ammonium glycyrrhizinate) in Glycyrrhizae, Notoginseng and Ginseng, the high performance liquid chromatography with diode array detector(HPLC-DAD) method was applied to an Ine...

Full description

Saved in:
Bibliographic Details
Published inTransactions of Tianjin University Vol. 19; no. 6; pp. 430 - 435
Main Author 张立国 方聪颖 欧阳霄雯 倪力军
Format Journal Article
LanguageEnglish
Published Berlin/Heidelberg Springer Berlin Heidelberg 01.12.2013
School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai 200237, China
Subjects
Online AccessGet full text
ISSN1006-4982
1995-8196
DOI10.1007/s12209-013-2096-3

Cover

More Information
Summary:To establish a method for determining five saponins(notoginsenoside R1, ginsenoside Rg1, ginsenoside Re, ginsenoside Rb1 and ammonium glycyrrhizinate) in Glycyrrhizae, Notoginseng and Ginseng, the high performance liquid chromatography with diode array detector(HPLC-DAD) method was applied to an Inertsil ODS-SP column(4.6 mm×250 mm, 5 μm) with a mobile phase consisting of acetonitrile-0.05% phosphoric acid in a gradient elution manner. The flow rate was 1.0 mL/min. The column temperature was 30 ℃ and the detection wavelengths were 203 nm and 237 nm, respectively. The linear ranges were 0.700,0—7.000,0 μg for R1(r=1.000,0), 0.751,1— 7.511,4 μg for Rg1(r=1.000,0), 0.677,2—6.771,6 μg for Re(r=1.000,0), 0.733,9—7.339,1 μg for Rb1(r= 1.000,0), and 0.540,0—5.399,8 μg for ammonium glycyrrhizinate(r=0.999,9), respectively. In addition, their average recoveries were 100.28%, 105.83%, 104.09%, 99.36% and 98.54%, respectively. The relative standard deviations(RSDs) of precision, reproducibility and recovery were all less than 1.5%. The results indicate that the method is simple, accurate and reproducible so that it can be used for the simultaneous determination of the five saponins in Chinese patent medicines containing the three kinds of herbs.
Bibliography:high performance liquid chromatography diode array detector Radix Glycyrrhizae Radix Notoginseng Radix Ginseng saponin
12-1248/T
To establish a method for determining five saponins(notoginsenoside R1, ginsenoside Rg1, ginsenoside Re, ginsenoside Rb1 and ammonium glycyrrhizinate) in Glycyrrhizae, Notoginseng and Ginseng, the high performance liquid chromatography with diode array detector(HPLC-DAD) method was applied to an Inertsil ODS-SP column(4.6 mm×250 mm, 5 μm) with a mobile phase consisting of acetonitrile-0.05% phosphoric acid in a gradient elution manner. The flow rate was 1.0 mL/min. The column temperature was 30 ℃ and the detection wavelengths were 203 nm and 237 nm, respectively. The linear ranges were 0.700,0—7.000,0 μg for R1(r=1.000,0), 0.751,1— 7.511,4 μg for Rg1(r=1.000,0), 0.677,2—6.771,6 μg for Re(r=1.000,0), 0.733,9—7.339,1 μg for Rb1(r= 1.000,0), and 0.540,0—5.399,8 μg for ammonium glycyrrhizinate(r=0.999,9), respectively. In addition, their average recoveries were 100.28%, 105.83%, 104.09%, 99.36% and 98.54%, respectively. The relative standard deviations(RSDs) of precision, reproducibility and recovery were all less than 1.5%. The results indicate that the method is simple, accurate and reproducible so that it can be used for the simultaneous determination of the five saponins in Chinese patent medicines containing the three kinds of herbs.
ISSN:1006-4982
1995-8196
DOI:10.1007/s12209-013-2096-3