Nanocrystalline Gd1–xCaxFeO3 sensors for detection of methanol gas
The sol-gel method was used to prepare the nanocrystalline Gd_(1–x)Ca_xFeO_3 (x=0–0.4) powders. The XRD results showed that all the Gd_(1–x)Ca_xFeO_3 (x=0–0.4) compounds crystallized as perovskite phase with orthorhombic structure. The doping of Ca in GdFeO_3 not only reduced the resistance, but als...
Saved in:
| Published in | Journal of rare earths Vol. 35; no. 7; pp. 690 - 696 |
|---|---|
| Main Author | |
| Format | Journal Article |
| Language | English |
| Published |
Elsevier B.V
01.07.2017
|
| Subjects | |
| Online Access | Get full text |
| ISSN | 1002-0721 2509-4963 |
| DOI | 10.1016/S1002-0721(17)60965-7 |
Cover
| Summary: | The sol-gel method was used to prepare the nanocrystalline Gd_(1–x)Ca_xFeO_3 (x=0–0.4) powders. The XRD results showed that all the Gd_(1–x)Ca_xFeO_3 (x=0–0.4) compounds crystallized as perovskite phase with orthorhombic structure. The doping of Ca in GdFeO_3 not only reduced the resistance, but also enhanced the response to methanol. The Gd_(0.9)Ca_(0.1)FeO_3 showed the best response to methanol among Gd_(1–x)Ca_xFeO_3 sensors. Besides, it showed good selectivity to methanol among methanol, ethanol, CO and formaldehyde gases. The responses at 260 oC for Gd_(0.9)Ca_(0.1)FeO_3-based sensor to 600 ppm methanol, ethanol and CO gases were 117.7, 72.7 and 31.9, respectively. Even at quite low gas concentrations, Gd_(0.9)Ca_(0.1)FeO_3-based sensor had an obvious response. At 260 °C, the response of 1.54 was obtained to be 45 ppm methanol. The experimental results showed that nanocrystalline Gd_(0.9)Ca_(0.1)FeO_3 based sensor can be used to detect methanol gas. |
|---|---|
| Bibliography: | 11-2788/TF The sol-gel method was used to prepare the nanocrystalline Gd_(1–x)Ca_xFeO_3 (x=0–0.4) powders. The XRD results showed that all the Gd_(1–x)Ca_xFeO_3 (x=0–0.4) compounds crystallized as perovskite phase with orthorhombic structure. The doping of Ca in GdFeO_3 not only reduced the resistance, but also enhanced the response to methanol. The Gd_(0.9)Ca_(0.1)FeO_3 showed the best response to methanol among Gd_(1–x)Ca_xFeO_3 sensors. Besides, it showed good selectivity to methanol among methanol, ethanol, CO and formaldehyde gases. The responses at 260 oC for Gd_(0.9)Ca_(0.1)FeO_3-based sensor to 600 ppm methanol, ethanol and CO gases were 117.7, 72.7 and 31.9, respectively. Even at quite low gas concentrations, Gd_(0.9)Ca_(0.1)FeO_3-based sensor had an obvious response. At 260 °C, the response of 1.54 was obtained to be 45 ppm methanol. The experimental results showed that nanocrystalline Gd_(0.9)Ca_(0.1)FeO_3 based sensor can be used to detect methanol gas. gas sensor methanol electrical properties perovskite rare earths |
| ISSN: | 1002-0721 2509-4963 |
| DOI: | 10.1016/S1002-0721(17)60965-7 |