Purpose: A compact proton therapy unit Monarch250 (Still River Systems, Littleton, MA) is under development and the first unit will be installed at our institution. Our purpose is to generate dose profiles and test beam characteristics for the proton therapy unit with Monte Carlo simulation and conf...
Saved in:
| Published in | Medical Physics Vol. 35; no. 6; p. 2846 |
|---|---|
| Main Authors | , , |
| Format | Conference Proceeding Journal Article |
| Language | English |
| Published |
American Association of Physicists in Medicine
01.06.2008
|
| Subjects | |
| Online Access | Get full text |
| ISSN | 0094-2405 2473-4209 |
| DOI | 10.1118/1.2962277 |
Cover
| Summary: | Purpose: A compact proton therapy unit Monarch250 (Still River Systems, Littleton, MA) is under development and the first unit will be installed at our institution. Our purpose is to generate dose profiles and test beam characteristics for the proton therapy unit with Monte Carlo simulation and configure a commercial treatment planning system (Varian, Palo Alto) using the simulated beam data. Method and Materials: Since the beam delivery apparatus is not installed yet, we used the design data provided by the manufacturer to model the beam line and calculate machine specific parameters such as water equivalent thickness of each component. We modeled the range modulator, second scatterer, range shifter, applicator, aperture and other components in detail. A Monte Carlo code (MCNPX, Los Alamos National Laboratory) was used to simulate the beam profiles. Up to 108 proton histories were tracked per simulation to achieve < 2% statistical uncertainties. The dose profiles and machine‐specific parameters were then entered into the treatment planning system for configuration. Results: A complete set of configuration parameters and beam profiles will be generated. The beam characteristics such as flatness, symmetry and penumbra and spread‐out Bragg peak will be evaluated against the machine specifications. The treatment planning system will be configured with the dose profiles from Monte Carlo simulation and machine specific parameters provided by the manufacturer. Conclusion: The Monte Carlo tool allows us to test the beam characteristics and configure a treatment planning system for a compact proton therapy unit before it is constructed. Validation of the Monte Carlo modeling will commence. Using a validated MC model to (partially or fully) commission the treatment plan and proton therapy machine is under investigation, which could significantly reduce the overall time and cost to model and commission proton beams for clinic use. |
|---|---|
| ISSN: | 0094-2405 2473-4209 |
| DOI: | 10.1118/1.2962277 |