Part Thickness Variation during the Vacuum Assisted Resin Infusion Process

An experimental procedure was designed to monitor the preform thickness change real-time throughout the vacuum assisted resin infusion( VARI) process. Two kinds of liquid with different viscosity were infused with different post-filling time. The variation of the part thickness during the VARI proce...

Full description

Saved in:
Bibliographic Details
Published in东华大学学报(英文版) Vol. 33; no. 4; pp. 673 - 677
Main Author 潘利剑 王英男 王召召 刘宇婷 段振锦 胡秀凤
Format Journal Article
LanguageEnglish
Published Center for Civil Aviation Composites, Donghua University, Shanghai 201620, China%College of Materials Science and Engineering, Donghua University, Shanghai201620, China%College of Mechanical Engineering, Donghua University, Shanghai 201620, China 31.08.2016
Subjects
Online AccessGet full text
ISSN1672-5220

Cover

More Information
Summary:An experimental procedure was designed to monitor the preform thickness change real-time throughout the vacuum assisted resin infusion( VARI) process. Two kinds of liquid with different viscosity were infused with different post-filling time. The variation of the part thickness during the VARI process was studied. And the effect of the post-filling time on the part thickness was investigated.The results indicate that the compaction behavior of the preform can be divided into three stages,and the fiber volume fraction varies with the post-filling time in a similar sinusoid form. In addition,the post-filling should be overtime for the greatest fiber volume fraction,and when the resin is infused with higher viscosity,the greatest fiber volume fraction is higher.
Bibliography:31-1920/N
An experimental procedure was designed to monitor the preform thickness change real-time throughout the vacuum assisted resin infusion( VARI) process. Two kinds of liquid with different viscosity were infused with different post-filling time. The variation of the part thickness during the VARI process was studied. And the effect of the post-filling time on the part thickness was investigated.The results indicate that the compaction behavior of the preform can be divided into three stages,and the fiber volume fraction varies with the post-filling time in a similar sinusoid form. In addition,the post-filling should be overtime for the greatest fiber volume fraction,and when the resin is infused with higher viscosity,the greatest fiber volume fraction is higher.
filling compaction resin viscosity VARI infusion relaxation saturated reservoir inlet