Repeatability of 68 Ga-PSMA-HBED-CC PET/CT-derived total molecular tumor volume

Molecular tumor volume (MTV) is a parameter of interest in prostate cancer for assessing total disease burden on prostate-specific membrane antigen (PSMA) PET. Although software segmentation tools can delineate whole-body MTV, a necessary step toward meaningful monitoring of total tumor burden and t...

Full description

Saved in:
Bibliographic Details
Published inJournal of Nuclear Medicine Vol. 63; no. 5; p. jnumed.121.262528
Main Authors Seifert, Robert, Sandach, Patrick, Kersting, David, Fendler, Wolfgang P., Hadaschik, Boris, Herrmann, Ken, Sunderland, John, Pollard, Janet
Format Journal Article
LanguageEnglish
Published United States 01.05.2022
Subjects
Online AccessGet full text
ISSN0161-5505
2159-662X
1535-5667
DOI10.2967/jnumed.121.262528

Cover

More Information
Summary:Molecular tumor volume (MTV) is a parameter of interest in prostate cancer for assessing total disease burden on prostate-specific membrane antigen (PSMA) PET. Although software segmentation tools can delineate whole-body MTV, a necessary step toward meaningful monitoring of total tumor burden and treatment response through PET is establishing the repeatability of these metrics. The present study assessed the repeatability of total MTV and related metrics for Ga-PSMA-HBED-CC in prostate cancer. Eighteen patients from a prior repeatability study who underwent 2 test-retest PSMA PET/CT scans within a mean interval of 5 d were reanalyzed. Within-subject coefficient of variation and repeatability coefficients (RCs) were analyzed on a per-lesion and per-patient basis. For the per-lesion analysis, individual lesions were segmented for analysis by a single reader. For the per-patient analysis, subgroups of up to 10 lesions (single reader) and the total tumor volume per patient were segmented (independently by 2 readers). Image parameters were MTV, SUV , SUV , SUV , total lesion PSMA, and the related metric PSMA quotient (which integrates lesion volume and PSMA avidity). In total, 192 segmentations were analyzed for the per-lesion analysis and 1,662 segmentations for the per-patient analysis (combining the 2 readers and 2 scans). The RC of the MTV of single lesions was 77% (95% CI, 63%-96%). The RC improved to 33% after aggregation of up to 10 manually selected lesions into subgroups assessed per patient (95% CI, 25%-46%). The RC of the semiautomatic MTV (the sum of all voxels in the whole-body total tumor segmentation per patient) was 35% (95% CI, 25%-50%), the Bland-Altman bias was -6.70 (95% CI, -14.32-0.93). Alternating readers between scans led to a comparable RC of 37% (95% CI, 28%-49%) for MTV , meaning that the metric is robust between scanning sessions and between readers. Ga-PSMA-HBED-CC PET-derived semiautomatic MTV is repeatable and reader-independent, with a change of ±35% representing a true change in tumor volume. Volumetry of single manually selected lesions has considerably lower repeatability, and volumetry based on subgroups of these lesions, although showing acceptable repeatability, is less systematic. The semiautomatic analysis of MTV used in this study offers an efficient and robust means of assessing response to therapy.
ISSN:0161-5505
2159-662X
1535-5667
DOI:10.2967/jnumed.121.262528