Comparing the usefulness of a new algorithm to measure visual field using the variational Bayes linear regression in glaucoma patients, in comparison to the Swedish interactive thresholding algorithm

Background/aimsWe previously reported that the visual field (VF) prediction model using the variational Bayes linear regression (VBLR) is useful for accurately predicting VF progression in glaucoma (Invest Ophthalmol Vis Sci. 2014, 2018). We constructed a VF measurement algorithm using VBLR, and the...

Full description

Saved in:
Bibliographic Details
Published inBritish journal of ophthalmology Vol. 106; no. 5; pp. 660 - 666
Main Authors Murata, Hiroshi, Asaoka, Ryo, Fujino, Yuri, Matsuura, Masato, Hirasawa, Kazunori, Shimada, Satoshi, Shoji, Nobuyuki
Format Journal Article
LanguageEnglish
Published BMA House, Tavistock Square, London, WC1H 9JR BMJ Publishing Group Ltd 01.05.2022
BMJ Publishing Group LTD
BMJ Publishing Group
Subjects
Online AccessGet full text
ISSN0007-1161
1468-2079
1468-2079
DOI10.1136/bjophthalmol-2020-318304

Cover

More Information
Summary:Background/aimsWe previously reported that the visual field (VF) prediction model using the variational Bayes linear regression (VBLR) is useful for accurately predicting VF progression in glaucoma (Invest Ophthalmol Vis Sci. 2014, 2018). We constructed a VF measurement algorithm using VBLR, and the purpose of this study was to investigate its usefulness.Method122 eyes of 73 patients with open-angle glaucoma were included in the current study. VF measurement was performed using the currently proposed VBLR programme with AP-7700 perimetry (KOWA). VF measurements were also conducted using the Swedish interactive thresholding algorithm (SITA) standard programme with Humphrey field analyser. VF measurements were performed using the 24–2 test grid. Visual sensitivities, test–retest reproducibility and measurement duration were compared between the two algorithms.ResultMean mean deviation (MD) values with SITA standard were −7.9 and −8.7 dB (first and second measurements), whereas those with VBLR-VF were −8.2 and −8.0 dB, respectively. There were no significant differences across these values. The correlation coefficient of MD values between the 2 algorithms was 0.97 or 0.98. Test–retest reproducibility did not differ between the two algorithms. Mean measurement duration with SITA standard was 6 min and 02 s or 6 min and 00 s (first or second measurement), whereas a significantly shorter duration was associated with VBLR-VF (5 min and 23 s or 5 min and 30 s).ConclusionVBLR-VF reduced test duration while maintaining the same accuracy as the SITA-standard.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0007-1161
1468-2079
1468-2079
DOI:10.1136/bjophthalmol-2020-318304