The diagnostic performance of urinary free cortisol is better than the cortisol:cortisone ratio in detecting de novo Cushing's syndrome: the use of a LC–MS/MS method in routine clinical practice
ObjectiveThe Endocrine Society Clinical Guidelines recommend measuring 24-h urinary free cortisol (UFF) levels using a highly accurate method as one of the first-line screening tests for the diagnosis of Cushing's Syndrome (CS). We evaluated the performance of UFF, urinary free cortisone (UFE),...
Saved in:
Published in | European journal of endocrinology Vol. 171; no. 1; pp. 1 - 7 |
---|---|
Main Authors | , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Bristol
Bioscientifica Ltd
01.07.2014
BioScientifica |
Subjects | |
Online Access | Get full text |
ISSN | 0804-4643 1479-683X 1479-683X |
DOI | 10.1530/EJE-14-0061 |
Cover
Summary: | ObjectiveThe Endocrine Society Clinical Guidelines recommend measuring 24-h urinary free cortisol (UFF) levels using a highly accurate method as one of the first-line screening tests for the diagnosis of Cushing's Syndrome (CS). We evaluated the performance of UFF, urinary free cortisone (UFE), and the UFF:UFE ratio, measured using a liquid chromatography–tandem mass spectrometry (LC–MS/MS) method.Subjects and methodsThe LC–MS/MS was used to analyze UFF and UFE levels in 43 surgically confirmed CS patients: 26 with Cushing's disease (CD, 16 de novo and ten recurrences), 11 with adrenal CS and six with ectopic CS; 22 CD patients in remission; 14 eu-cortisolemic CD patients receiving medical therapy; 60 non-CS patients; and 70 healthy controls. Sensitivity and specificity were determined in the combined groups of non-CS patients, healthy controls, and CD in remission.ResultsUFF>170 nmol/24 h showed 98.7% specificity and 100% sensitivity for de novo CS, while sensitivity was 80% for recurrent CD patients, who were characterized by lower UFF levels. The UFF:UFE and UFF+UFE showed lower sensitivity and specificity than UFF. Ectopic CS patients had the highest UFF and UFF:UFE levels, which were normal in the CD remission patients and in those receiving medical therapy.ConclusionsOur data suggest high diagnostic performance of UFF excretion measured using LC–MS/MS, in detecting de novo CS. UFF:UFE and UFF+UFE assessments are not useful in the first step of CS diagnosis, although high levels were found to be indicative of ectopic CS. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0804-4643 1479-683X 1479-683X |
DOI: | 10.1530/EJE-14-0061 |