The Effect of Pulsatile Versus Nonpulsatile Blood Flow on Viscoelasticity and Red Blood Cell Aggregation in Extracorporeal Circulation
Background: Extracorporeal circulation (ECC) can induce alterations in blood viscoelasticity and cause red blood cell (RBC) aggregation. In this study, the authors evaluated the effects of pump flow pulsatility on blood viscoelasticity and RBC aggregation. Methods: Mongrel dogs were randomly assigne...
Saved in:
Published in | Journal of chest surgery pp. 145 - 150 |
---|---|
Main Authors | , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
대한흉부외과학회
01.06.2016
|
Subjects | |
Online Access | Get full text |
ISSN | 2765-1606 2765-1614 |
Cover
Abstract | Background: Extracorporeal circulation (ECC) can induce alterations in blood viscoelasticity and cause red blood cell (RBC) aggregation. In this study, the authors evaluated the effects of pump flow pulsatility on blood viscoelasticity and RBC aggregation. Methods: Mongrel dogs were randomly assigned to two groups: a nonpulsatile pump group (n=6) or a pulsatile pump group (n=6). After ECC was started at a pump flow rate of 80 mL/kg/min, cardiac fibrillation was induced. Blood sampling was performed before and at 1, 2, and 3 hours after ECC commencement.
To eliminate bias induced by hematocrit and plasma, all blood samples were adjusted to a hematocrit of 45% using baseline plasma. Blood viscoelasticity, plasma viscosity, hematocrit, arterial blood gas analysis, central venous O2 saturation, and lactate were measured. Results: The blood viscosity and aggregation index decreased abruptly 1 hour after ECC and then remained low during ECC in both groups, but blood elasticity did not change during ECC. Blood viscosity, blood elasticity, plasma viscosity, and the aggregation index were not significantly different in the groups at any time. Hematocrit decreased abruptly 1 hour after ECC in both groups due to dilution by the priming solution used. Conclusion: After ECC, blood viscoelasticity and RBC aggregation were not different in the pulsatile and nonpulsatile groups in the adult dog model. Furthermore, pulsatile flow did not have a more harmful effect on blood viscoelasticity or RBC aggregation than nonpulsatile flow. KCI Citation Count: 1 |
---|---|
AbstractList | Background: Extracorporeal circulation (ECC) can induce alterations in blood viscoelasticity and cause red blood cell (RBC) aggregation. In this study, the authors evaluated the effects of pump flow pulsatility on blood viscoelasticity and RBC aggregation. Methods: Mongrel dogs were randomly assigned to two groups: a nonpulsatile pump group (n=6) or a pulsatile pump group (n=6). After ECC was started at a pump flow rate of 80 mL/kg/min, cardiac fibrillation was induced. Blood sampling was performed before and at 1, 2, and 3 hours after ECC commencement.
To eliminate bias induced by hematocrit and plasma, all blood samples were adjusted to a hematocrit of 45% using baseline plasma. Blood viscoelasticity, plasma viscosity, hematocrit, arterial blood gas analysis, central venous O2 saturation, and lactate were measured. Results: The blood viscosity and aggregation index decreased abruptly 1 hour after ECC and then remained low during ECC in both groups, but blood elasticity did not change during ECC. Blood viscosity, blood elasticity, plasma viscosity, and the aggregation index were not significantly different in the groups at any time. Hematocrit decreased abruptly 1 hour after ECC in both groups due to dilution by the priming solution used. Conclusion: After ECC, blood viscoelasticity and RBC aggregation were not different in the pulsatile and nonpulsatile groups in the adult dog model. Furthermore, pulsatile flow did not have a more harmful effect on blood viscoelasticity or RBC aggregation than nonpulsatile flow. KCI Citation Count: 1 |
Author | 임춘학 손국희 선경 김지성 양성 손호성 안치범 강양준 김명곤 이소영 |
Author_xml | – sequence: 1 fullname: 안치범 organization: (가천대학교) – sequence: 2 fullname: 강양준 organization: (Department of Mechatronics, Gwangju Institute of Science and Technology) – sequence: 3 fullname: 김명곤 organization: (Department of Mechatronics, Gwangju Institute of Science and Technology) – sequence: 4 fullname: 양성 organization: (광주과학기술원) – sequence: 5 fullname: 임춘학 organization: (고려대학교) – sequence: 6 fullname: 손호성 organization: (고려대학교) – sequence: 7 fullname: 김지성 organization: (가천대학교 의과대학 흉부외과) – sequence: 8 fullname: 이소영 organization: (가천대학교 흉부외과) – sequence: 9 fullname: 손국희 organization: (가천대학교) – sequence: 10 fullname: 선경 organization: (고려대학교) |
BackLink | https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002113182$$DAccess content in National Research Foundation of Korea (NRF) |
BookMark | eNqVi8FqAjEURUNRqK3-w9t2IZiOk-nWDiN2U4oMbkPMvIzBR54kGdr-gN9dEXHf1bnce-6TGAUO-CAmr5Uq51LJ5eieF-pRzFLy-0VZFJV6k-VEnNsDQuMc2gzs4GugZLInhB3GNCT45HC6d-_E3MGa-Bs4wM4ny0gmZW99_gUTOthid7NqJIJV30fsL-eL7gM0Pzkay_HEEQ1B7aMd6LpOxdgZSji78Vm8rJu23sxDdPpovWbjr-xZH6NebdsPLaWqlqUq_uP-AUEXWwU |
ContentType | Journal Article |
DBID | ACYCR |
DatabaseName | Korean Citation Index |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
EISSN | 2765-1614 |
EndPage | 150 |
ExternalDocumentID | oai_kci_go_kr_ARTI_1167456 |
GroupedDBID | ACYCR ALMA_UNASSIGNED_HOLDINGS GROUPED_DOAJ PGMZT RPM |
ID | FETCH-nrf_kci_oai_kci_go_kr_ARTI_11674563 |
ISSN | 2765-1606 |
IngestDate | Tue Apr 22 02:56:12 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-nrf_kci_oai_kci_go_kr_ARTI_11674563 |
Notes | http://www.kjtcvs.org G704-000272.2016.46.3.001 |
ParticipantIDs | nrf_kci_oai_kci_go_kr_ARTI_1167456 |
PublicationCentury | 2000 |
PublicationDate | 2016-06 |
PublicationDateYYYYMMDD | 2016-06-01 |
PublicationDate_xml | – month: 06 year: 2016 text: 2016-06 |
PublicationDecade | 2010 |
PublicationTitle | Journal of chest surgery |
PublicationYear | 2016 |
Publisher | 대한흉부외과학회 |
Publisher_xml | – name: 대한흉부외과학회 |
SSID | ssib053376815 ssib044743717 ssj0002513323 |
Score | 3.9103434 |
Snippet | Background: Extracorporeal circulation (ECC) can induce alterations in blood viscoelasticity and cause red blood cell (RBC) aggregation. In this study, the... |
SourceID | nrf |
SourceType | Open Website |
StartPage | 145 |
SubjectTerms | 흉부외과학 |
Title | The Effect of Pulsatile Versus Nonpulsatile Blood Flow on Viscoelasticity and Red Blood Cell Aggregation in Extracorporeal Circulation |
URI | https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002113182 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
ispartofPNX | Journal of Chest Surgery, 2016, 49(3), , pp.145-150 |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1La9wwEBabnHIpDU3pK0GU6lAWF8uWvdbRdjYkhfSUlNwW2ysvSxa7OF7yOOSY35qf0RlZuyuHhqa9mEE7loTnY_YbaTQi5MvIL7xsynNH5jJwROFzJyvz0pFKQfQMCMj1Dv7pj_D4XHy_CC4Gg0cra2nZ5t-Kuz-eK_kfq0Ib2BVPyf6DZdedQgPIYF94goXh-WIbm_LDmMq2XGBqzkINcRFsCQ6srn6t2xLMUB8eLepr3B_4Ob8qagXMGZOq21tzTHFqtFJc0ItnEIrPslUy5PimbcB7Yt1jrEWczpvC3Pz1DL_VN3ENr6xj12BXNk6ZDFgUoZBIJkFIWOIxKTYqMUtc1ELdkEmOQgyc1-2pSEzSgJfjmEWBbvFBqzfQ6uVIsITb6xs83ORhaURiR1GqezzEoWWqhUMWST3BUP8EXUqWRGawJF0pSy3APNKNX_VGYeDw0DUVuO02Lixfzrs6l4YW8K4-br9i95N_0l7N7stiPpnVk8tmApHJyQT3u4CsbpEtn6M_Pr0fr_yeEEDjrLAaGDgEgYamIaPw8BIefVPheu5AhaqmtKjQ2WvyytiYxh0gd8lAVW_IA4CRdmCkdUnXYKQdGKkNRqphRhGMtK7oEzBSACMFMBotBCO1wEjnFe2DkVpg3CNfj8Zn6bED89Yf5_mP5L8l21VdqXeElq6rwlyVvJxmAi-fzCJX5l6mAiFE6Y3ek89_7-_DS5Q-kp0N_D6R7bZZqn0gnG1-oK31G_g6ePM |
linkProvider | ISSN International Centre |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=The+Effect+of+Pulsatile+Versus+Nonpulsatile+Blood+Flow+on+Viscoelasticity+and+Red+Blood+Cell+Aggregation+in+Extracorporeal+Circulation&rft.jtitle=Journal+of+chest+surgery&rft.au=%EC%95%88%EC%B9%98%EB%B2%94&rft.au=%EA%B0%95%EC%96%91%EC%A4%80&rft.au=%EA%B9%80%EB%AA%85%EA%B3%A4&rft.au=%EC%96%91%EC%84%B1&rft.date=2016-06-01&rft.pub=%EB%8C%80%ED%95%9C%ED%9D%89%EB%B6%80%EC%99%B8%EA%B3%BC%ED%95%99%ED%9A%8C&rft.issn=2765-1606&rft.eissn=2765-1614&rft.spage=145&rft.epage=150&rft.externalDBID=n%2Fa&rft.externalDocID=oai_kci_go_kr_ARTI_1167456 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2765-1606&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2765-1606&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2765-1606&client=summon |