Effects of body parameters on renal cortical stiffness measured by shear-wave elastography in patients with kidney transplantation

The results of elastic imaging in evaluating the function and histopathological changes of allogeneic renal transplantation are contradictory, one of the important reasons may be that there are differences in human parameters related to kidney transplantation among individuals. The purpose of this s...

Full description

Saved in:
Bibliographic Details
Published inZhong nan da xue xue bao. Journal of Central South University. Yi xue ban Vol. 47; no. 10; p. 1385
Main Authors Yang, Shuting, Liu, Yuwan, Zuo, Huilan, Feng, Linna, Xu, Chengshu, Gu, Lan, Gao, Feng
Format Journal Article
LanguageChinese
English
Published China 28.10.2022
Subjects
Online AccessGet full text
ISSN1672-7347
DOI10.11817/j.issn.1672-7347.2022.220170

Cover

Abstract The results of elastic imaging in evaluating the function and histopathological changes of allogeneic renal transplantation are contradictory, one of the important reasons may be that there are differences in human parameters related to kidney transplantation among individuals. The purpose of this study is to explore the related human body parameters on shear-wave elastography (SWE) effects on quantitative stiffness of graft cortex. From March 2021 to November 2021, a total of 63 patients with allogeneic kidney transplantation in the Department of Ultrasonography, Third Xiangya Hospital, Central South University, were selected to collect the parameters of two-dimensional, color Doppler and SWE. The subjects were divided into a <20% group and a 20%-30% group according to the variation of cortical hardness measurement. Mann Whitney test was used to compare the differences in relevant human parameters, and Spearman rank correlation was used to analyze the correlation between relevant human parameters and cortical hardness of transplanted kidney. There was no significant difference between the 2 groups in age, sex, postoperative time, resistance index of interlobar artery, SCr, blood uric acid, ratio of fat layer to muscle layer, and BMI (all >0.05). Compared with the <20% group, the patients in the 20%-30% group had smaller cortical hardness of the transplanted kidney, greater total distance between the transplanted kidney and the skin surface, and thicker fat layer or muscle layer in front of the transplanted kidney (all 0.05). The age of patients, the total distance from the transplanted kidney to the skin surface, the thickness of fat layer and muscle layer, the ratio of fat layer to muscle layer, BMI, and the variation of cortical hardness were significantly negatively correlated with the cortical hardness of the transplanted kidney (all 0.05). Human parameters relevant to kidney transplantation affect the accuracy of SWE in measuring the cortical hardness of the transplanted kidney. It is very important to obtain the highly stabile elastic measurement value and interpret the elastic measurement results according to different levels of human body related parameters in combination with individual conditions.
AbstractList The results of elastic imaging in evaluating the function and histopathological changes of allogeneic renal transplantation are contradictory, one of the important reasons may be that there are differences in human parameters related to kidney transplantation among individuals. The purpose of this study is to explore the related human body parameters on shear-wave elastography (SWE) effects on quantitative stiffness of graft cortex. From March 2021 to November 2021, a total of 63 patients with allogeneic kidney transplantation in the Department of Ultrasonography, Third Xiangya Hospital, Central South University, were selected to collect the parameters of two-dimensional, color Doppler and SWE. The subjects were divided into a <20% group and a 20%-30% group according to the variation of cortical hardness measurement. Mann Whitney test was used to compare the differences in relevant human parameters, and Spearman rank correlation was used to analyze the correlation between relevant human parameters and cortical hardness of transplanted kidney. There was no significant difference between the 2 groups in age, sex, postoperative time, resistance index of interlobar artery, SCr, blood uric acid, ratio of fat layer to muscle layer, and BMI (all >0.05). Compared with the <20% group, the patients in the 20%-30% group had smaller cortical hardness of the transplanted kidney, greater total distance between the transplanted kidney and the skin surface, and thicker fat layer or muscle layer in front of the transplanted kidney (all 0.05). The age of patients, the total distance from the transplanted kidney to the skin surface, the thickness of fat layer and muscle layer, the ratio of fat layer to muscle layer, BMI, and the variation of cortical hardness were significantly negatively correlated with the cortical hardness of the transplanted kidney (all 0.05). Human parameters relevant to kidney transplantation affect the accuracy of SWE in measuring the cortical hardness of the transplanted kidney. It is very important to obtain the highly stabile elastic measurement value and interpret the elastic measurement results according to different levels of human body related parameters in combination with individual conditions.
The results of elastic imaging in evaluating the function and histopathological changes of allogeneic renal transplantation are contradictory, one of the important reasons may be that there are differences in human parameters related to kidney transplantation among individuals. The purpose of this study is to explore the related human body parameters on shear-wave elastography (SWE) effects on quantitative stiffness of graft cortex.OBJECTIVESThe results of elastic imaging in evaluating the function and histopathological changes of allogeneic renal transplantation are contradictory, one of the important reasons may be that there are differences in human parameters related to kidney transplantation among individuals. The purpose of this study is to explore the related human body parameters on shear-wave elastography (SWE) effects on quantitative stiffness of graft cortex.From March 2021 to November 2021, a total of 63 patients with allogeneic kidney transplantation in the Department of Ultrasonography, Third Xiangya Hospital, Central South University, were selected to collect the parameters of two-dimensional, color Doppler and SWE. The subjects were divided into a <20% group and a 20%-30% group according to the variation of cortical hardness measurement. Mann Whitney U test was used to compare the differences in relevant human parameters, and Spearman rank correlation was used to analyze the correlation between relevant human parameters and cortical hardness of transplanted kidney.METHODSFrom March 2021 to November 2021, a total of 63 patients with allogeneic kidney transplantation in the Department of Ultrasonography, Third Xiangya Hospital, Central South University, were selected to collect the parameters of two-dimensional, color Doppler and SWE. The subjects were divided into a <20% group and a 20%-30% group according to the variation of cortical hardness measurement. Mann Whitney U test was used to compare the differences in relevant human parameters, and Spearman rank correlation was used to analyze the correlation between relevant human parameters and cortical hardness of transplanted kidney.There was no significant difference between the 2 groups in age, sex, postoperative time, resistance index of interlobar artery, SCr, blood uric acid, ratio of fat layer to muscle layer, and BMI (all P>0.05). Compared with the <20% group, the patients in the 20%-30% group had smaller cortical hardness of the transplanted kidney, greater total distance between the transplanted kidney and the skin surface, and thicker fat layer or muscle layer in front of the transplanted kidney (all P<0.05). The age of patients, the total distance from the transplanted kidney to the skin surface, the thickness of fat layer and muscle layer, the ratio of fat layer to muscle layer, BMI, and the variation of cortical hardness were significantly negatively correlated with the cortical hardness of the transplanted kidney (all P<0.05).RESULTSThere was no significant difference between the 2 groups in age, sex, postoperative time, resistance index of interlobar artery, SCr, blood uric acid, ratio of fat layer to muscle layer, and BMI (all P>0.05). Compared with the <20% group, the patients in the 20%-30% group had smaller cortical hardness of the transplanted kidney, greater total distance between the transplanted kidney and the skin surface, and thicker fat layer or muscle layer in front of the transplanted kidney (all P<0.05). The age of patients, the total distance from the transplanted kidney to the skin surface, the thickness of fat layer and muscle layer, the ratio of fat layer to muscle layer, BMI, and the variation of cortical hardness were significantly negatively correlated with the cortical hardness of the transplanted kidney (all P<0.05).Human parameters relevant to kidney transplantation affect the accuracy of SWE in measuring the cortical hardness of the transplanted kidney. It is very important to obtain the highly stabile elastic measurement value and interpret the elastic measurement results according to different levels of human body related parameters in combination with individual conditions.CONCLUSIONSHuman parameters relevant to kidney transplantation affect the accuracy of SWE in measuring the cortical hardness of the transplanted kidney. It is very important to obtain the highly stabile elastic measurement value and interpret the elastic measurement results according to different levels of human body related parameters in combination with individual conditions.
Author Yang, Shuting
Zuo, Huilan
Feng, Linna
Xu, Chengshu
Gu, Lan
Gao, Feng
Liu, Yuwan
Author_xml – sequence: 1
  givenname: Shuting
  surname: Yang
  fullname: Yang, Shuting
  email: yangshutingsm@163.com
  organization: Department of Ultrasonography, Third Xiangya Hospital, Central South University, Changsha 410013. yangshutingsm@163.com
– sequence: 2
  givenname: Yuwan
  surname: Liu
  fullname: Liu, Yuwan
  organization: Department of Ultrasonography, Third Xiangya Hospital, Central South University, Changsha 410013
– sequence: 3
  givenname: Huilan
  surname: Zuo
  fullname: Zuo, Huilan
  organization: Department of Ultrasonography, Changsha Central Hospital, Changsha 410018
– sequence: 4
  givenname: Linna
  surname: Feng
  fullname: Feng, Linna
  organization: Department of Ultrasonography, Third Xiangya Hospital, Central South University, Changsha 410013
– sequence: 5
  givenname: Chengshu
  surname: Xu
  fullname: Xu, Chengshu
  organization: Department of Ultrasonography, Third Xiangya Hospital, Central South University, Changsha 410013
– sequence: 6
  givenname: Lan
  surname: Gu
  fullname: Gu, Lan
  organization: Department of Blood Transfusion, Third Xiangya Hospital, Central South University, Changsha 410013, China
– sequence: 7
  givenname: Feng
  surname: Gao
  fullname: Gao, Feng
  email: gf0731@163.com
  organization: Department of Ultrasonography, Third Xiangya Hospital, Central South University, Changsha 410013. gf0731@163.com
BackLink https://www.ncbi.nlm.nih.gov/pubmed/36411689$$D View this record in MEDLINE/PubMed
BookMark eNo9kEtPwzAQhH0ooqX0LyBfkLgk-JU4PqKqPKRKXHqPnGRNXRIn2C5VrvxygijsZVazo0-jvUIz1ztA6JaSlNKCyvtDakNwKc0lSyQXMmWEsZQxQiWZocW_P0erEA6EEJbRn7lEc54LSvNCLdDXxhioY8C9wVXfjHjQXncQwU-Wwx6cbnHd-2jraQnRGuMgBNyBDkcPDa5GHPagfXLSn4Ch1SH2b14P-xFbN9GiBTfhTzbu8bttHIw4eu3C0GoXp2vvrtGF0W2A1VmXaPe42a2fk-3r08v6YZsMWa4SwXghWU4qxoQgUjVKqkwJ2hSGVVlFCqlqJiHjWU1yWRnOqNKCC0OKrBGS8SW6-8UOvv84QohlZ0MN7dQD-mMomeSK5JnK6RS9OUePVQdNOXjbaT-Wf2_j3zTudHg
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
7X8
DOI 10.11817/j.issn.1672-7347.2022.220170
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList MEDLINE
MEDLINE - Academic
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
DocumentTitleAlternate 人体参数对剪切波弹性成像定量移植肾皮质硬度的影响
ExternalDocumentID 36411689
Genre Journal Article
GrantInformation_xml – fundername: the Natural Science Foundation of Hunan Province
  grantid: 2021JJ31001
GroupedDBID ALMA_UNASSIGNED_HOLDINGS
CGR
CUY
CVF
ECM
EIF
NPM
RPM
7X8
ID FETCH-LOGICAL-p569-42387260b2244079d9795941d8f2b5b0879c27e535c067bf3219a434f085d4723
ISSN 1672-7347
IngestDate Thu Jul 10 23:51:57 EDT 2025
Thu Jan 02 22:34:43 EST 2025
IsPeerReviewed false
IsScholarly true
Issue 10
Keywords hardness of renal cortex
shear-wave elastography
body parameters
body mass index
kidney transplantation
Language Chinese
English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-p569-42387260b2244079d9795941d8f2b5b0879c27e535c067bf3219a434f085d4723
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
PMID 36411689
PQID 2739065961
PQPubID 23479
ParticipantIDs proquest_miscellaneous_2739065961
pubmed_primary_36411689
PublicationCentury 2000
PublicationDate 2022-Oct-28
20221028
PublicationDateYYYYMMDD 2022-10-28
PublicationDate_xml – month: 10
  year: 2022
  text: 2022-Oct-28
  day: 28
PublicationDecade 2020
PublicationPlace China
PublicationPlace_xml – name: China
PublicationTitle Zhong nan da xue xue bao. Journal of Central South University. Yi xue ban
PublicationTitleAlternate Zhong Nan Da Xue Xue Bao Yi Xue Ban
PublicationYear 2022
SSID ssj0002511111
Score 2.2330952
Snippet The results of elastic imaging in evaluating the function and histopathological changes of allogeneic renal transplantation are contradictory, one of the...
SourceID proquest
pubmed
SourceType Aggregation Database
Index Database
StartPage 1385
SubjectTerms Elasticity Imaging Techniques - methods
Humans
Kidney
Kidney Transplantation
Transplantation, Homologous
Ultrasonography - methods
Title Effects of body parameters on renal cortical stiffness measured by shear-wave elastography in patients with kidney transplantation
URI https://www.ncbi.nlm.nih.gov/pubmed/36411689
https://www.proquest.com/docview/2739065961
Volume 47
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVAQN
  databaseName: PubMed Central
  issn: 1672-7347
  databaseCode: RPM
  dateStart: 20210101
  customDbUrl:
  isFulltext: true
  dateEnd: 99991231
  titleUrlDefault: https://www.ncbi.nlm.nih.gov/pmc/
  omitProxy: true
  ssIdentifier: ssj0002511111
  providerName: National Library of Medicine
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9QwELZKKyEuCMSrvGQk4BIlxHk4yRGhrVaolMtW2vYS2UnMprTJsk1U2iP_if_HjOM8xEuFw0a71saJMl9mvhmPZwh5mYdgZgTjdsThdQtckduJEoUdJEwqV4R-LnFF98MBnx8G75fhcmvr-yRrqW2kk139dl_J_0gVxkCuuEv2HyQ7TAoD8B3kC0eQMByvJePZmIwh6_zSwjreZ5jfotcANkWli39sunA1vMtKacV21sUFNfU8x47W9gX2ICqASDemgrU1llw1-98-l3kF-qPRxdBPRTVZwjfc9niFfYsqUBi5sL62hf5IUTvWhPWaaLKlW_dN0kIc66g0JwxwPepj2au26S0s5g6VrTYc7cX41-NWh3znbXk6DoKsPpm4Q9cjvA9vgGcMdsGbamQegQvgd2U5e5VtfhlouhMFzPyuA9CvliHW9aRO9KzOMKuD13Q8D8sIjSaxTwM4-JjuHe7vp4vZcvF6_cXGZmW4qG86t9wgOx4YE3cSJEICgF4b052fh8vcJK_6m3jzt1v4s5-j-c7iDrltREbfdqi7S3auVrSo7pFvBnS0VhRBR0fQ0bqiGnS0Bx0dQEd70FF5SUfQ0SnoaFnRHnQUQUc70NGfQHefLPZmi3dz2zTysNchT2xg7HEEfrMEuhi4UZIn2OA-YHmsPBlKN46SzIuK0A8z4E5S-WBFReAHCtyBPIg8_wHZruqqeERoIDiSWBVmGVB_FgquOMslWMlMYT79LnnRP78U9CQufomqqNvzFGh6gjkEnO2Sh92DTdddQZfU5wFjPE4eX-PsJ-TWCNOnZLvZtMUz4KWNfK5R8APYJJQF
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Effects+of+body+parameters+on+renal+cortical+stiffness+measured+by+shear-wave+elastography+in+patients+with+kidney+transplantation&rft.jtitle=Zhong+nan+da+xue+xue+bao.+Journal+of+Central+South+University.+Yi+xue+ban&rft.au=Yang%2C+Shuting&rft.au=Liu%2C+Yuwan&rft.au=Zuo%2C+Huilan&rft.au=Feng%2C+Linna&rft.date=2022-10-28&rft.issn=1672-7347&rft.volume=47&rft.issue=10&rft.spage=1385&rft_id=info:doi/10.11817%2Fj.issn.1672-7347.2022.220170&rft.externalDBID=NO_FULL_TEXT
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1672-7347&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1672-7347&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1672-7347&client=summon