Accelerated 3D multi-channel B 1 + mapping at 7 T for the brain and heart
To acquire accurate volumetric multi-channel maps in under 14 s whole-brain or 23 heartbeats whole-heart for parallel transmit (pTx) applications at 7 T. We evaluate the combination of three recently proposed techniques. The acquisition of multi-channel transmit array maps is accelerated using trans...
Saved in:
Published in | Magnetic resonance in medicine Vol. 92; no. 5; p. 2007 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
01.11.2024
|
Subjects | |
Online Access | Get full text |
ISSN | 1522-2594 1522-2594 |
DOI | 10.1002/mrm.30201 |
Cover
Abstract | To acquire accurate volumetric multi-channel
maps in under 14 s whole-brain or 23 heartbeats whole-heart for parallel transmit (pTx) applications at 7 T.
We evaluate the combination of three recently proposed techniques. The acquisition of multi-channel transmit array
maps is accelerated using transmit low rank (TxLR) with absolute
mapping (Sandwich) acquired in a
time-interleaved acquisition of modes (B1TIAMO) fashion. Simulations using synthetic body images derived from Sim4Life were used to test the achievable acceleration for small scan matrices of 24 × 24. Next, we evaluated the method by retrospectively undersampling a fully sampled
library of nine subjects in the brain. Finally, Cartesian undersampled phantom and in vivo images were acquired in both the brain of three subjects (8Tx/32 receive [Rx]) and the heart of another three subjects (8Tx/8Rx) at 7 T.
Simulation and in vivo results show that volumetric multi-channel
maps can be acquired using acceleration factors of 4 in the body, reducing the acquisition time to within 23 heartbeats, which was previously not possible. In silico heart simulations demonstrated a RMS error to the fully sampled native resolution ground truth of 4.2° when combined in first-order circularly polarized mode (mean flip angle 66°) at an acceleration factor of 4. The 14 s 3D
maps acquired in the brain have a RMS error of 1.9° to the fully sampled (mean flip angle 86°).
The proposed method is demonstrated as a fast pTx calibration technique in the brain and a promising method for pTx calibration in the body. |
---|---|
AbstractList | To acquire accurate volumetric multi-channel B 1 + $$ {\mathrm{B}}_1^{+} $$ maps in under 14 s whole-brain or 23 heartbeats whole-heart for parallel transmit (pTx) applications at 7 T.PURPOSETo acquire accurate volumetric multi-channel B 1 + $$ {\mathrm{B}}_1^{+} $$ maps in under 14 s whole-brain or 23 heartbeats whole-heart for parallel transmit (pTx) applications at 7 T.We evaluate the combination of three recently proposed techniques. The acquisition of multi-channel transmit array B 1 + $$ {\mathrm{B}}_1^{+} $$ maps is accelerated using transmit low rank (TxLR) with absolute B 1 + $$ {\mathrm{B}}_1^{+} $$ mapping (Sandwich) acquired in a B 1 + $$ {\mathrm{B}}_1^{+} $$ time-interleaved acquisition of modes (B1TIAMO) fashion. Simulations using synthetic body images derived from Sim4Life were used to test the achievable acceleration for small scan matrices of 24 × 24. Next, we evaluated the method by retrospectively undersampling a fully sampled B 1 + $$ {\mathrm{B}}_1^{+} $$ library of nine subjects in the brain. Finally, Cartesian undersampled phantom and in vivo images were acquired in both the brain of three subjects (8Tx/32 receive [Rx]) and the heart of another three subjects (8Tx/8Rx) at 7 T.THEORY AND METHODSWe evaluate the combination of three recently proposed techniques. The acquisition of multi-channel transmit array B 1 + $$ {\mathrm{B}}_1^{+} $$ maps is accelerated using transmit low rank (TxLR) with absolute B 1 + $$ {\mathrm{B}}_1^{+} $$ mapping (Sandwich) acquired in a B 1 + $$ {\mathrm{B}}_1^{+} $$ time-interleaved acquisition of modes (B1TIAMO) fashion. Simulations using synthetic body images derived from Sim4Life were used to test the achievable acceleration for small scan matrices of 24 × 24. Next, we evaluated the method by retrospectively undersampling a fully sampled B 1 + $$ {\mathrm{B}}_1^{+} $$ library of nine subjects in the brain. Finally, Cartesian undersampled phantom and in vivo images were acquired in both the brain of three subjects (8Tx/32 receive [Rx]) and the heart of another three subjects (8Tx/8Rx) at 7 T.Simulation and in vivo results show that volumetric multi-channel B 1 + $$ {\mathrm{B}}_1^{+} $$ maps can be acquired using acceleration factors of 4 in the body, reducing the acquisition time to within 23 heartbeats, which was previously not possible. In silico heart simulations demonstrated a RMS error to the fully sampled native resolution ground truth of 4.2° when combined in first-order circularly polarized mode (mean flip angle 66°) at an acceleration factor of 4. The 14 s 3D B 1 + $$ {\mathrm{B}}_1^{+} $$ maps acquired in the brain have a RMS error of 1.9° to the fully sampled (mean flip angle 86°).RESULTSSimulation and in vivo results show that volumetric multi-channel B 1 + $$ {\mathrm{B}}_1^{+} $$ maps can be acquired using acceleration factors of 4 in the body, reducing the acquisition time to within 23 heartbeats, which was previously not possible. In silico heart simulations demonstrated a RMS error to the fully sampled native resolution ground truth of 4.2° when combined in first-order circularly polarized mode (mean flip angle 66°) at an acceleration factor of 4. The 14 s 3D B 1 + $$ {\mathrm{B}}_1^{+} $$ maps acquired in the brain have a RMS error of 1.9° to the fully sampled (mean flip angle 86°).The proposed method is demonstrated as a fast pTx calibration technique in the brain and a promising method for pTx calibration in the body.CONCLUSIONThe proposed method is demonstrated as a fast pTx calibration technique in the brain and a promising method for pTx calibration in the body. To acquire accurate volumetric multi-channel maps in under 14 s whole-brain or 23 heartbeats whole-heart for parallel transmit (pTx) applications at 7 T. We evaluate the combination of three recently proposed techniques. The acquisition of multi-channel transmit array maps is accelerated using transmit low rank (TxLR) with absolute mapping (Sandwich) acquired in a time-interleaved acquisition of modes (B1TIAMO) fashion. Simulations using synthetic body images derived from Sim4Life were used to test the achievable acceleration for small scan matrices of 24 × 24. Next, we evaluated the method by retrospectively undersampling a fully sampled library of nine subjects in the brain. Finally, Cartesian undersampled phantom and in vivo images were acquired in both the brain of three subjects (8Tx/32 receive [Rx]) and the heart of another three subjects (8Tx/8Rx) at 7 T. Simulation and in vivo results show that volumetric multi-channel maps can be acquired using acceleration factors of 4 in the body, reducing the acquisition time to within 23 heartbeats, which was previously not possible. In silico heart simulations demonstrated a RMS error to the fully sampled native resolution ground truth of 4.2° when combined in first-order circularly polarized mode (mean flip angle 66°) at an acceleration factor of 4. The 14 s 3D maps acquired in the brain have a RMS error of 1.9° to the fully sampled (mean flip angle 86°). The proposed method is demonstrated as a fast pTx calibration technique in the brain and a promising method for pTx calibration in the body. |
Author | Kent, James L Chiew, Mark Hess, Aaron T Valkovič, Ladislav de Buck, Matthijs H S Dragonu, Iulius |
Author_xml | – sequence: 1 givenname: James L orcidid: 0000-0001-6482-7515 surname: Kent fullname: Kent, James L organization: Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK – sequence: 2 givenname: Matthijs H S orcidid: 0000-0001-8217-8192 surname: de Buck fullname: de Buck, Matthijs H S organization: Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands – sequence: 3 givenname: Iulius surname: Dragonu fullname: Dragonu, Iulius organization: Research & Collaborations GB&I, Siemens Healthcare Ltd, Camberley, UK – sequence: 4 givenname: Mark orcidid: 0000-0001-6272-8783 surname: Chiew fullname: Chiew, Mark organization: Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada – sequence: 5 givenname: Ladislav orcidid: 0000-0003-2567-3642 surname: Valkovič fullname: Valkovič, Ladislav organization: Department of Imaging Methods, Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia – sequence: 6 givenname: Aaron T orcidid: 0000-0002-9289-5619 surname: Hess fullname: Hess, Aaron T organization: Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/38934380$$D View this record in MEDLINE/PubMed |
BookMark | eNpNjztPwzAURi1URB8w8AfQHZFQih9xY4-lvCpVYukeOfY1DYqd4CQD_76VKBLT9w1HRzpzMoltREJuGV0ySvljSGEpKKfsgsyY5DzjUueTf39K5n3_RSnVusivyFQoLXKh6Ixs19Zig8kM6EA8Qxiboc7swcSIDTwBgwcIpuvq-AlmgAL24NsEwwGhSqaOYKKDA5o0XJNLb5oeb867IPvXl_3mPdt9vG03613WyRXNmPXKOatzKY0qVkKaaoWy8N5Z5Suj0SpqvdMMuWNeuwJRU4ko6AmTFRcLcv-r7VL7PWI_lKHuTwmNidiOfSlowRWTmusTendGxyqgK7tUB5N-yr96cQTBC1sN |
ContentType | Journal Article |
Copyright | 2024 The Author(s). Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine. |
Copyright_xml | – notice: 2024 The Author(s). Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine. |
DBID | CGR CUY CVF ECM EIF NPM 7X8 |
DOI | 10.1002/mrm.30201 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed MEDLINE - Academic |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine Physics |
EISSN | 1522-2594 |
ExternalDocumentID | 38934380 |
Genre | Journal Article |
GrantInformation_xml | – fundername: Royal Society grantid: 221805/Z/20/Z – fundername: Engineering and Physical Sciences Research Council grantid: EP/V519741/1 – fundername: Wellcome Trust grantid: 203139/Z/16/Z – fundername: Agentúra na Podporu Výskumu a Vývoja grantid: 21-0299 – fundername: Wellcome Trust grantid: 203139/A/16/Z – fundername: Vedecká Grantová Agentúra MŠVVaŠ SR a SAV grantid: 2/0004/23 |
GroupedDBID | --- -DZ .3N .55 .GA .Y3 05W 0R~ 10A 1L6 1OB 1OC 1ZS 31~ 33P 3O- 3SF 3WU 4.4 4ZD 50Y 50Z 51W 51X 52M 52N 52O 52P 52R 52S 52T 52U 52V 52W 52X 53G 5GY 5RE 5VS 66C 702 7PT 8-0 8-1 8-3 8-4 8-5 8UM 930 A01 A03 AAESR AAEVG AAHQN AAIPD AAMMB AAMNL AANHP AANLZ AAONW AASGY AAXRX AAYCA AAZKR ABCQN ABCUV ABDPE ABEML ABIJN ABJNI ABLJU ABPVW ABQWH ABXGK ACAHQ ACBWZ ACCZN ACFBH ACGFO ACGFS ACGOF ACIWK ACMXC ACPOU ACPRK ACRPL ACSCC ACXBN ACXQS ACYXJ ADBBV ADBTR ADEOM ADIZJ ADKYN ADMGS ADNMO ADOZA ADXAS ADZMN AEFGJ AEGXH AEIGN AEIMD AENEX AEUYR AEYWJ AFBPY AFFNX AFFPM AFGKR AFRAH AFWVQ AFZJQ AGHNM AGQPQ AGXDD AGYGG AHBTC AHMBA AIACR AIAGR AIDQK AIDYY AITYG AIURR ALAGY ALMA_UNASSIGNED_HOLDINGS ALUQN ALVPJ AMBMR AMYDB ASPBG ATUGU AVWKF AZBYB AZFZN AZVAB BAFTC BDRZF BFHJK BHBCM BMXJE BROTX BRXPI BY8 C45 CGR CS3 CUY CVF D-6 D-7 D-E D-F DCZOG DPXWK DR2 DRFUL DRMAN DRSTM DU5 EBD EBS ECM EIF EJD EMOBN F00 F01 F04 FEDTE FUBAC G-S G.N GNP GODZA H.X HBH HDBZQ HF~ HGLYW HHY HHZ HVGLF HZ~ I-F IX1 J0M JPC KBYEO KQQ LATKE LAW LC2 LC3 LEEKS LH4 LITHE LOXES LP6 LP7 LUTES LW6 LYRES M65 MEWTI MK4 MRFUL MRMAN MRSTM MSFUL MSMAN MSSTM MXFUL MXMAN MXSTM N04 N05 N9A NF~ NNB NPM O66 O9- OIG OVD P2P P2W P2X P2Z P4B P4D PALCI PQQKQ Q.N Q11 QB0 QRW R.K RIWAO RJQFR ROL RX1 RYL SAMSI SUPJJ SV3 TEORI TUS TWZ UB1 V2E V8K W8V W99 WBKPD WHWMO WIB WIH WIJ WIK WIN WJL WOHZO WQJ WVDHM WXI WXSBR X7M XG1 XPP XV2 ZGI ZXP ZZTAW ~IA ~WT 7X8 |
ID | FETCH-LOGICAL-p560-1cf8ddc9455a87635ab6e57ffdc8fba9ec80cfd91e2d1f9d7ee905ee306e55b23 |
ISSN | 1522-2594 |
IngestDate | Fri Sep 05 04:17:25 EDT 2025 Mon Jul 21 05:46:15 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 5 |
Keywords | mapping parallel transmit B1TIAMO TxLR ultrahigh field MRI |
Language | English |
License | 2024 The Author(s). Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine. |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-p560-1cf8ddc9455a87635ab6e57ffdc8fba9ec80cfd91e2d1f9d7ee905ee306e55b23 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ORCID | 0000-0001-8217-8192 0000-0002-9289-5619 0000-0003-2567-3642 0000-0001-6272-8783 0000-0001-6482-7515 |
PMID | 38934380 |
PQID | 3072815929 |
PQPubID | 23479 |
ParticipantIDs | proquest_miscellaneous_3072815929 pubmed_primary_38934380 |
PublicationCentury | 2000 |
PublicationDate | 2024-Nov 20241101 |
PublicationDateYYYYMMDD | 2024-11-01 |
PublicationDate_xml | – month: 11 year: 2024 text: 2024-Nov |
PublicationDecade | 2020 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Magnetic resonance in medicine |
PublicationTitleAlternate | Magn Reson Med |
PublicationYear | 2024 |
SSID | ssj0009974 |
Score | 2.4630976 |
Snippet | To acquire accurate volumetric multi-channel
maps in under 14 s whole-brain or 23 heartbeats whole-heart for parallel transmit (pTx) applications at 7 T.
We... To acquire accurate volumetric multi-channel B 1 + $$ {\mathrm{B}}_1^{+} $$ maps in under 14 s whole-brain or 23 heartbeats whole-heart for parallel transmit... |
SourceID | proquest pubmed |
SourceType | Aggregation Database Index Database |
StartPage | 2007 |
SubjectTerms | Adult Algorithms Brain - diagnostic imaging Computer Simulation Heart - diagnostic imaging Humans Image Processing, Computer-Assisted - methods Imaging, Three-Dimensional - methods Magnetic Resonance Imaging - methods Male Phantoms, Imaging Reproducibility of Results |
Title | Accelerated 3D multi-channel B 1 + mapping at 7 T for the brain and heart |
URI | https://www.ncbi.nlm.nih.gov/pubmed/38934380 https://www.proquest.com/docview/3072815929 |
Volume | 92 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
journalDatabaseRights | – providerCode: PRVWIB databaseName: Wiley Online Library - Core collection (SURFmarket) issn: 1522-2594 databaseCode: DR2 dateStart: 19990101 customDbUrl: isFulltext: true eissn: 1522-2594 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0009974 providerName: Wiley-Blackwell |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9NAEF5BEagXBAVKeWmREBfLxWt7be-xaVoFaIqEXCk3a59tUeOkiX3h1zO7dmwXilS4WNEqsa2dL7Pz_AahDypVkSDa-CQEFyWWJPKZMBx8HiFMkipGtY13TE-TyVn8ZUZnfbmt6y6pxL78eWtfyf9IFdZArrZL9h8k290UFuAzyBeuIGG43knGB1LCqWHJHpQXjZviQN-28pb6yht5BOQ68uZ86XqieOWlXt6VFQo7G8KlDuxM6xsR-ik_L3XD7WwNdfvXh6_-noX_qhvKAldn63UxZKVdvrjpA6qqi8sfa2_SB1jHK36-KGunmuqry7oz6Q8vHKvtoHuojUWEcduUN1Cf4NqCQ9WECPQta63OZeEAW3SoQINmCO4fmr1hip2v5vsRWLikP742KfvTb8Xx2clJkR_N8o_La98OFrMJ-HbKyn30IEyTxA65GH_vGcYYc0Td3UtuyKeC8FP3rL87H84IyZ-gx633gA8aKDxF93S5gx5NW8nsoIeuoFeun6HPA2zgaIxvYAOPMMEebpGBeYVTnGNABgZkYIcMDMjADhnPUX58lB9O_HZshr8E89Un0mRKSRZTyh3dIBeJpqkxSmZGcKZlFkijGNGhIoapVGsWUK3Bd9SUijB6gbbKRalfIqyMzkwgCI-VihMiMiMpmPtMZXEUZCbeQ-83G1OAVrKpJl7qRb0u4OQIM7CUQ7aHdpsdK5YNfUphTWQ75-DVHX79Gm33OHuDtqpVrd-CFViJd06OvwD-tlxF |
linkProvider | Wiley-Blackwell |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Accelerated+3D+multi-channel+B+1+%2B+mapping+at+7+T+for+the+brain+and+heart&rft.jtitle=Magnetic+resonance+in+medicine&rft.au=Kent%2C+James+L&rft.au=de+Buck%2C+Matthijs+H+S&rft.au=Dragonu%2C+Iulius&rft.au=Chiew%2C+Mark&rft.date=2024-11-01&rft.issn=1522-2594&rft.eissn=1522-2594&rft.volume=92&rft.issue=5&rft.spage=2007&rft_id=info:doi/10.1002%2Fmrm.30201&rft.externalDBID=NO_FULL_TEXT |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1522-2594&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1522-2594&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1522-2594&client=summon |