Wavefront sensorless adaptive optics ophthalmoscopy in the human eye
Wavefront sensor noise and fidelity place a fundamental limit on achievable image quality in current adaptive optics ophthalmoscopes. Additionally, the wavefront sensor 'beacon' can interfere with visual experiments. We demonstrate real-time (25 Hz), wavefront sensorless adaptive optics im...
Saved in:
Published in | Optics express Vol. 19; no. 15; pp. 14160 - 14171 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
United States
Optical Society of America
18.07.2011
|
Subjects | |
Online Access | Get full text |
ISSN | 1094-4087 1094-4087 |
DOI | 10.1364/OE.19.014160 |
Cover
Abstract | Wavefront sensor noise and fidelity place a fundamental limit on achievable image quality in current adaptive optics ophthalmoscopes. Additionally, the wavefront sensor 'beacon' can interfere with visual experiments. We demonstrate real-time (25 Hz), wavefront sensorless adaptive optics imaging in the living human eye with image quality rivaling that of wavefront sensor based control in the same system. A stochastic parallel gradient descent algorithm directly optimized the mean intensity in retinal image frames acquired with a confocal adaptive optics scanning laser ophthalmoscope (AOSLO). When imaging through natural, undilated pupils, both control methods resulted in comparable mean image intensities. However, when imaging through dilated pupils, image intensity was generally higher following wavefront sensor-based control. Despite the typically reduced intensity, image contrast was higher, on average, with sensorless control. Wavefront sensorless control is a viable option for imaging the living human eye and future refinements of this technique may result in even greater optical gains. |
---|---|
AbstractList | Wavefront sensor noise and fidelity place a fundamental limit on achievable image quality in current adaptive optics ophthalmoscopes. Additionally, the wavefront sensor 'beacon' can interfere with visual experiments. We demonstrate real-time (25 Hz), wavefront sensorless adaptive optics imaging in the living human eye with image quality rivaling that of wavefront sensor based control in the same system. A stochastic parallel gradient descent algorithm directly optimized the mean intensity in retinal image frames acquired with a confocal adaptive optics scanning laser ophthalmoscope (AOSLO). When imaging through natural, undilated pupils, both control methods resulted in comparable mean image intensities. However, when imaging through dilated pupils, image intensity was generally higher following wavefront sensor-based control. Despite the typically reduced intensity, image contrast was higher, on average, with sensorless control. Wavefront sensorless control is a viable option for imaging the living human eye and future refinements of this technique may result in even greater optical gains. Wavefront sensor noise and fidelity place a fundamental limit on achievable image quality in current adaptive optics ophthalmoscopes. Additionally, the wavefront sensor 'beacon' can interfere with visual experiments. We demonstrate real-time (25 Hz), wavefront sensorless adaptive optics imaging in the living human eye with image quality rivaling that of wavefront sensor based control in the same system. A stochastic parallel gradient descent algorithm directly optimized the mean intensity in retinal image frames acquired with a confocal adaptive optics scanning laser ophthalmoscope (AOSLO). When imaging through natural, undilated pupils, both control methods resulted in comparable mean image intensities. However, when imaging through dilated pupils, image intensity was generally higher following wavefront sensor-based control. Despite the typically reduced intensity, image contrast was higher, on average, with sensorless control. Wavefront sensorless control is a viable option for imaging the living human eye and future refinements of this technique may result in even greater optical gains.Wavefront sensor noise and fidelity place a fundamental limit on achievable image quality in current adaptive optics ophthalmoscopes. Additionally, the wavefront sensor 'beacon' can interfere with visual experiments. We demonstrate real-time (25 Hz), wavefront sensorless adaptive optics imaging in the living human eye with image quality rivaling that of wavefront sensor based control in the same system. A stochastic parallel gradient descent algorithm directly optimized the mean intensity in retinal image frames acquired with a confocal adaptive optics scanning laser ophthalmoscope (AOSLO). When imaging through natural, undilated pupils, both control methods resulted in comparable mean image intensities. However, when imaging through dilated pupils, image intensity was generally higher following wavefront sensor-based control. Despite the typically reduced intensity, image contrast was higher, on average, with sensorless control. Wavefront sensorless control is a viable option for imaging the living human eye and future refinements of this technique may result in even greater optical gains. |
Author | Sredar, Nripun Porter, Jason Li, Chaohong Hofer, Heidi Queener, Hope |
Author_xml | – sequence: 1 givenname: Heidi surname: Hofer fullname: Hofer, Heidi email: hhofer@optometry.uh.edu organization: College of Optometry, University of Houston, Houston Texas 77204, USA. hhofer@optometry.uh.edu – sequence: 2 givenname: Nripun surname: Sredar fullname: Sredar, Nripun – sequence: 3 givenname: Hope surname: Queener fullname: Queener, Hope – sequence: 4 givenname: Chaohong surname: Li fullname: Li, Chaohong – sequence: 5 givenname: Jason surname: Porter fullname: Porter, Jason |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/21934779$$D View this record in MEDLINE/PubMed |
BookMark | eNpVkEtLw0AUhQep2IfuXEt2rlLnJpOZzEaQWh9Q6EZxGW4zNyaSzMRMUui_N2AVXZ0D9-M7cOdsYp0lxi6BLyGW4ma7XoJechAg-QmbAdciFDxVkz99yubef_ARUlqdsWkEOhZK6Rm7f8M9FZ2zfeDJetfV5H2ABtu-2lPgxsj9GGVfYt04n7v2EFQ26EsKyqFBG9CBztlpgbWni2Mu2OvD-mX1FG62j8-ru03Ygk76EI1JpNDIOREHqXmBiYxEkRdcYWIgUQag4CgoTbmhndilGsBozaU0Ix8v2O23tx12DZmcbN9hnbVd1WB3yBxW2f-Lrcrs3e2zGFSa6mQUXB8FnfscyPdZU_mc6hotucFnqY5VFCkVj-TV36nfjZ_PxV-43nMb |
ContentType | Journal Article |
Copyright | 2011 Optical Society of America 2011 OSA |
Copyright_xml | – notice: 2011 Optical Society of America 2011 OSA |
DBID | CGR CUY CVF ECM EIF NPM 7X8 5PM |
DOI | 10.1364/OE.19.014160 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed MEDLINE - Academic PubMed Central (Full Participant titles) |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) MEDLINE - Academic |
DatabaseTitleList | MEDLINE MEDLINE - Academic |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Physics |
EISSN | 1094-4087 |
EndPage | 14171 |
ExternalDocumentID | PMC3178895 21934779 |
Genre | Research Support, U.S. Gov't, Non-P.H.S Research Support, Non-U.S. Gov't Journal Article Research Support, N.I.H., Extramural |
GrantInformation_xml | – fundername: NEI NIH HHS grantid: P30 EY007551 – fundername: NEI NIH HHS grantid: P30EY07551 – fundername: NEI NIH HHS grantid: R01 EY019069 – fundername: NEI NIH HHS grantid: BRP-EY01437 – fundername: National Institutes of Health grantid: RO1 EY019069 and P30 EY07551 – fundername: NSF Science and Technology Center for Adaptive Optics – fundername: University of Houston grantid: BRP-EY01437 – fundername: Texas Advanced Research Program grantid: G096152 |
GroupedDBID | --- 123 29N 2WC 8SL AAFWJ AAWJZ ACGFO ADBBV AEDJG AENEX AFPKN AKGWG ALMA_UNASSIGNED_HOLDINGS ATHME AYPRP AZSQR AZYMN BAWUL BCNDV C1A CGR CS3 CUY CVF DIK DSZJF DU5 E3Z EBS ECM EIF EJD F5P GROUPED_DOAJ GX1 KQ8 M~E NPM OFLFD OK1 OPJBK OPLUZ OVT P2P RNS ROS TR2 TR6 XSB 7X8 ROL 5PM |
ID | FETCH-LOGICAL-p195t-add5649a00ee01690fa5624fcf07a5d157d11f0a4e880deb4b8911d99066d1693 |
ISSN | 1094-4087 |
IngestDate | Thu Aug 21 14:31:54 EDT 2025 Sat Sep 27 19:13:30 EDT 2025 Mon Jul 21 06:03:06 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 15 |
Language | English |
License | This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-p195t-add5649a00ee01690fa5624fcf07a5d157d11f0a4e880deb4b8911d99066d1693 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
OpenAccessLink | http://dx.doi.org/10.1364/OE.19.014160 |
PMID | 21934779 |
PQID | 893722773 |
PQPubID | 23479 |
PageCount | 12 |
ParticipantIDs | pubmedcentral_primary_oai_pubmedcentral_nih_gov_3178895 proquest_miscellaneous_893722773 pubmed_primary_21934779 |
PublicationCentury | 2000 |
PublicationDate | 2011-07-18 |
PublicationDateYYYYMMDD | 2011-07-18 |
PublicationDate_xml | – month: 07 year: 2011 text: 2011-07-18 day: 18 |
PublicationDecade | 2010 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Optics express |
PublicationTitleAlternate | Opt Express |
PublicationYear | 2011 |
Publisher | Optical Society of America |
Publisher_xml | – name: Optical Society of America |
SSID | ssj0014797 |
Score | 2.3183048 |
Snippet | Wavefront sensor noise and fidelity place a fundamental limit on achievable image quality in current adaptive optics ophthalmoscopes. Additionally, the... |
SourceID | pubmedcentral proquest pubmed |
SourceType | Open Access Repository Aggregation Database Index Database |
StartPage | 14160 |
SubjectTerms | Adaptation, Ocular - physiology Adult Algorithms Eye - anatomy & histology Humans Image Processing, Computer-Assisted Ophthalmoscopes Ophthalmoscopy - methods Optical Phenomena Photoreceptor Cells, Vertebrate - cytology Retina - anatomy & histology |
Title | Wavefront sensorless adaptive optics ophthalmoscopy in the human eye |
URI | https://www.ncbi.nlm.nih.gov/pubmed/21934779 https://www.proquest.com/docview/893722773 https://pubmed.ncbi.nlm.nih.gov/PMC3178895 |
Volume | 19 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3fa9swEBZrxqAvo_vRLt1W9LC34lS2Zct6HF1GGFtLoWV9C7Ikk0BjmcYZax_6t_ck2U7SpdDuxRhZtuC-8-lOOn2H0JeEFwq8_jwoMkECqpXd3w0V6LJIYstQx1zluV8n6eiC_rhMLpdl7tzpkjofyNuN50r-B1VoA1ztKdlnINt9FBrgHvCFKyAM1ydh_Fv80YVlIDicQzRq7L655WgSlcsHMpWjYDbVpJ6Iq5mxB1Bu2rxGX5tP36xlAp36N_TfqkvMcJm1hcfVcmJNuyWZa618cvYJ2J1Fp2NnNjJu-puqU5uf02Zz30xMM1mq5eIpCxrzqL19hGgQQs5mjmwNKF9VlGTFHIbg7pGNhjpOKUj3dDgI-YD80w3EXM0caGBQY8p8vZkHxNjtoy30MmLgONm8zbtht4VEGWfNSQcY7Gh1KMcA7V_eFFg8zI9dcTjOd9DrJlLAXz3sb9ALXb5Fr1zGrpy_Q9868PESfNyCjz34eB18PC0xgI8d-BjAf48uvg_Pj0dBUxIjqEKe1AHMRklKuSBEa8ujQwoBDiwtZEHg51JhwlQYFkRQDXZZ6Zzmmf31wOVIU2V5d3ZRrzSl_oAwzzgjEsL1SEoKYb6II5mmGpolBVss-wi3khmDybH7SKLUZjEfWxc3ihiL-2jPC2pceWqUcSvWPmJrIuw6WDbz9SfldOJYzcGRzTKe7D_6zY9oe6mTn1Cvvl7oz-AR1vmBW0k5cPjfA8PCZI0 |
linkProvider | ISSN International Centre |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Wavefront+sensorless+adaptive+optics+ophthalmoscopy+in+the+human+eye&rft.jtitle=Optics+express&rft.au=Hofer%2C+Heidi&rft.au=Sredar%2C+Nripun&rft.au=Queener%2C+Hope&rft.au=Li%2C+Chaohong&rft.date=2011-07-18&rft.eissn=1094-4087&rft.volume=19&rft.issue=15&rft.spage=14160&rft_id=info:doi/10.1364%2FOE.19.014160&rft_id=info%3Apmid%2F21934779&rft.externalDocID=21934779 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1094-4087&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1094-4087&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1094-4087&client=summon |