CLINICAL VALUES OF THE FUNCTIONAL SHOULDER COMPLEX MEASURED WITH A DYNAMOMETER

The function of the shoulder joint, which consists of three anatomical joints and one functional joint, is completely different from that of other joints.Therefore, assessment with an isokinetic dynamometer doesn't directly reflect shoulder function. The aim of this study was to review the chec...

Full description

Saved in:
Bibliographic Details
Published inJournal of The Showa Medical Association Vol. 57; no. 3; pp. 293 - 297
Main Authors UCHIKAWA Tomoyoshi, TSUTSUI Hiroaki, MIHARA Kenichi, HOKARI Shigeru, SUZUKI Kazuhide, UESATO Hajime, OSHIMA Yawara, KAN Naoki, MAKIUCHI Daisuke, MATSUHISA Takayuki, YAMAGUCHI Mitsukuni, ENDO Masaru, YAMAMOTO Ryuji
Format Journal Article
LanguageEnglish
Published 昭和大学学士会 1997
The Showa University Society
Subjects
Online AccessGet full text
ISSN0037-4342
2185-0976
DOI10.14930/jsma1939.57.293

Cover

Abstract The function of the shoulder joint, which consists of three anatomical joints and one functional joint, is completely different from that of other joints.Therefore, assessment with an isokinetic dynamometer doesn't directly reflect shoulder function. The aim of this study was to review the check points and the clinical values of this system.(Method) Ten normal volunteers were examined. External rotational strength was measured with a KIN-COM 500H under various conditions at 60 and 180 degrees/second concentric contraction.(Results) In each subject, mean force and mean torque of exteral rotation varied with different conditions. It was difficult to measure the peak torque and peak force accurately. The forces scattered depending on whether the body was fixed or not during examination.Overall, it was difficult to measure shoulder strength under uniform, proper conditions.(Conclusion) When we measured the muscle strength of the shoulder joint using an isokinetic dynamometer, the most important point was to standardize the measuring position and conditions. 筋力測定機KIN-COM 500Hを用い, 肩関節に既往のない健常成人10例 (男性5例5関節, 女性5例5関節) 計10例10関節について肩関節外旋運動筋力評価を行い, 肢位条件の変化により得られる結果について検討した. (1) 第1肢位および第2肢位でのFORCEの平均値, (2) トルクの3回のそれぞれの値と平均値, (3) 同一被験者で3回測定施行したデータの解析, (4) 連続18回運動, (5) 角速度の変化, (6) 肩甲骨を固定した場合としない場合との比較, (7) 個々の被験者における, 日常測定時に見落としやすいチェックポイントの7項目についての結果を, トルク測定装置を用いる場合の基本的な変動要因 (1) 機器の特性, (2) 測定方法による要因, (3) 被測定者における変動要因の3つに分けて考察した.肩関節が各運動ともshoulder complexとしての運動であることを考慮すると, 筋力測定機器は肩関節の単一筋の筋力測定目的には使用できず, 同機器を用いて肩関節の筋力評価を行う場合, 測定肢位や測定時の固定などを厳密に規定することは当然であるがそれでも再現性については疑問が残る.
AbstractList The function of the shoulder joint, which consists of three anatomical joints and one functional joint, is completely different from that of other joints.Therefore, assessment with an isokinetic dynamometer doesn't directly reflect shoulder function. The aim of this study was to review the check points and the clinical values of this system.(Method) Ten normal volunteers were examined. External rotational strength was measured with a KIN-COM 500H under various conditions at 60 and 180 degrees/second concentric contraction.(Results) In each subject, mean force and mean torque of exteral rotation varied with different conditions. It was difficult to measure the peak torque and peak force accurately. The forces scattered depending on whether the body was fixed or not during examination.Overall, it was difficult to measure shoulder strength under uniform, proper conditions.(Conclusion) When we measured the muscle strength of the shoulder joint using an isokinetic dynamometer, the most important point was to standardize the measuring position and conditions. 筋力測定機KIN-COM 500Hを用い, 肩関節に既往のない健常成人10例 (男性5例5関節, 女性5例5関節) 計10例10関節について肩関節外旋運動筋力評価を行い, 肢位条件の変化により得られる結果について検討した. (1) 第1肢位および第2肢位でのFORCEの平均値, (2) トルクの3回のそれぞれの値と平均値, (3) 同一被験者で3回測定施行したデータの解析, (4) 連続18回運動, (5) 角速度の変化, (6) 肩甲骨を固定した場合としない場合との比較, (7) 個々の被験者における, 日常測定時に見落としやすいチェックポイントの7項目についての結果を, トルク測定装置を用いる場合の基本的な変動要因 (1) 機器の特性, (2) 測定方法による要因, (3) 被測定者における変動要因の3つに分けて考察した.肩関節が各運動ともshoulder complexとしての運動であることを考慮すると, 筋力測定機器は肩関節の単一筋の筋力測定目的には使用できず, 同機器を用いて肩関節の筋力評価を行う場合, 測定肢位や測定時の固定などを厳密に規定することは当然であるがそれでも再現性については疑問が残る.
Author SUZUKI Kazuhide
KAN Naoki
MIHARA Kenichi
TSUTSUI Hiroaki
YAMAGUCHI Mitsukuni
OSHIMA Yawara
MATSUHISA Takayuki
UCHIKAWA Tomoyoshi
MAKIUCHI Daisuke
HOKARI Shigeru
ENDO Masaru
UESATO Hajime
YAMAMOTO Ryuji
Author_FL 山本 龍二
三原 研一
松久 孝行
牧内 大輔
山口 光圀
菅 直樹
遠藤 優
上里 元
保刈 成
筒井 廣明
内川 友義
鈴木 一秀
大島 和
Author_FL_xml – sequence: 1
  fullname: 内川 友義
– sequence: 2
  fullname: 筒井 廣明
– sequence: 3
  fullname: 三原 研一
– sequence: 4
  fullname: 保刈 成
– sequence: 5
  fullname: 鈴木 一秀
– sequence: 6
  fullname: 上里 元
– sequence: 7
  fullname: 大島 和
– sequence: 8
  fullname: 菅 直樹
– sequence: 9
  fullname: 牧内 大輔
– sequence: 10
  fullname: 松久 孝行
– sequence: 11
  fullname: 山口 光圀
– sequence: 12
  fullname: 遠藤 優
– sequence: 13
  fullname: 山本 龍二
Author_xml – sequence: 1
  fullname: UCHIKAWA Tomoyoshi
  organization: Department of Orthopaedic Surgery, Showa University, Fujigaoka Hospital | 昭和大学藤が丘病院整形外科
– sequence: 2
  fullname: TSUTSUI Hiroaki
  organization: 昭和大学藤が丘病院整形外科 | Department of Orthopaedic Surgery, Showa University, Fujigaoka Hospital
– sequence: 3
  fullname: MIHARA Kenichi
  organization: 昭和大学藤が丘病院整形外科 | Department of Orthopaedic Surgery, Showa University, Fujigaoka Hospital
– sequence: 4
  fullname: HOKARI Shigeru
  organization: Department of Orthopaedic Surgery, Showa University, Fujigaoka Hospital | 昭和大学藤が丘病院整形外科
– sequence: 5
  fullname: SUZUKI Kazuhide
  organization: Department of Orthopaedic Surgery, Showa University, Fujigaoka Hospital | 昭和大学藤が丘病院整形外科
– sequence: 6
  fullname: UESATO Hajime
  organization: Department of Orthopaedic Surgery, Showa University, Fujigaoka Hospital | 昭和大学藤が丘病院整形外科
– sequence: 7
  fullname: OSHIMA Yawara
  organization: 昭和大学藤が丘病院整形外科 | Department of Orthopaedic Surgery, Showa University, Fujigaoka Hospital
– sequence: 8
  fullname: KAN Naoki
  organization: Department of Orthopaedic Surgery, Showa University, Fujigaoka Hospital | 昭和大学藤が丘病院整形外科
– sequence: 9
  fullname: MAKIUCHI Daisuke
  organization: Department of Orthopaedic Surgery, Showa University, Fujigaoka Hospital | 昭和大学藤が丘病院整形外科
– sequence: 10
  fullname: MATSUHISA Takayuki
  organization: Department of Orthopaedic Surgery, Showa University, Fujigaoka Hospital | 昭和大学藤が丘病院整形外科
– sequence: 11
  fullname: YAMAGUCHI Mitsukuni
  organization: 昭和大学藤が丘リハビリテーション病院
– sequence: 12
  fullname: ENDO Masaru
  organization: 昭和大学藤が丘リハビリテーション病院
– sequence: 13
  fullname: YAMAMOTO Ryuji
  organization: 片山整形外科記念病院
BackLink https://cir.nii.ac.jp/crid/1390001204836515072$$DView record in CiNii
BookMark eNotj01PhDAYhBuzJuK6d489eAXbvi1tjwS6QlLA8OHHyRSWJmwUD_j_IxudwzOHSWYyt2i3fC8TQveURJRrII_n9ctRDToSMmIarlDAqBIh0TLeoYAQkCEHzm7QYV3PZBPXlBMWoCq1RVWkicUvie1Ni-sj7nKDj32VdkVdbUGb173NTIPTuny25g2XJmn7xmT4tehynODsvUrKujSdae7QtXef63T49z3qjqZL89DWT5eVcNH6JxRMwEClj6Xi9CSEU1NMThuEnKikAhyoyXvPvB_dxBlzbBiFAA6DVoQz2KOHv9plnj_G-UIKertFGeEKYkEFkQx-AZLuSSw
ContentType Journal Article
DBID RYH
DOI 10.14930/jsma1939.57.293
DatabaseName CiNii Complete
DatabaseTitleList
DeliveryMethod fulltext_linktorsrc
DocumentTitleAlternate 筋力測定器を用いた肩関節筋力評価の検討
DocumentTitle_FL 筋力測定器を用いた肩関節筋力評価の検討
EISSN 2185-0976
EndPage 297
ExternalDocumentID 130001824501
GroupedDBID ALMA_UNASSIGNED_HOLDINGS
JSF
KQ8
RJT
RYH
ID FETCH-LOGICAL-n99t-5253b17f67841d55a8e60d8e657e17153a38efff2ffcae422a2bc55343b980423
ISSN 0037-4342
IngestDate Thu Jun 26 22:41:47 EDT 2025
IsPeerReviewed false
IsScholarly false
Issue 3
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-n99t-5253b17f67841d55a8e60d8e657e17153a38efff2ffcae422a2bc55343b980423
PageCount 5
ParticipantIDs nii_cinii_1390001204836515072
PublicationCentury 1900
PublicationDate 1997
PublicationDateYYYYMMDD 1997-01-01
PublicationDate_xml – year: 1997
  text: 1997
PublicationDecade 1990
PublicationTitle Journal of The Showa Medical Association
PublicationTitleAlternate J Showa Med Assoc
J. Showa. Med. Assoc
昭医会誌
昭和医会誌
昭和医学会雑誌
PublicationTitle_FL J Showa Med Assoc
J. Showa. Med. Assoc
昭医会誌
昭和医会誌
昭和医学会雑誌
PublicationYear 1997
Publisher 昭和大学学士会
The Showa University Society
Publisher_xml – name: The Showa University Society
– name: 昭和大学学士会
SSID ssj0000491402
Score 1.2530501
Snippet The function of the shoulder joint, which consists of three anatomical joints and one functional joint, is completely different from that of other...
SourceID nii
SourceType Publisher
StartPage 293
SubjectTerms concentric contraction
isokinetic contraction
joint torque
shoulder
求心性収縮
等運動性収縮

関節のトルク
Title CLINICAL VALUES OF THE FUNCTIONAL SHOULDER COMPLEX MEASURED WITH A DYNAMOMETER
URI https://cir.nii.ac.jp/crid/1390001204836515072
Volume 57
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVAFT
  databaseName: Open Access Digital Library
  customDbUrl:
  eissn: 2185-0976
  dateEnd: 20121231
  omitProxy: true
  ssIdentifier: ssj0000491402
  issn: 0037-4342
  databaseCode: KQ8
  dateStart: 19390101
  isFulltext: true
  titleUrlDefault: http://grweb.coalliance.org/oadl/oadl.html
  providerName: Colorado Alliance of Research Libraries
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Jj9MwFLaq4cIFgQCxDfIBn6qU1onj-OhJU6VMF2gTKCcUJ85MkKaROq0Q_CX-JM9JmnYGEItUWZa7ONX36W1-fg-hV6lrmjm4fUtTnVuOGKSWADVpUVtpW7uJyKuWLNOZG8bOmxVbdTrfj7KWdlvVS7_98l7J_6AKa4CruSX7D8i2PwoLMAd8YQSEYfwrjP3JeFbVM3gvJ3Gw3GfwjOKZ39S4XYbzeDI0pQ_m07eTYNWdBiBIF8EQPPcoBKkw_DiT0_k0iILFb-xUQ6TlZfklaQ91bkMKeMV-OD6XH2Q3Kq_Kr-X1ZdGGBJYxvMbdsNiUYK22AI9DuZDmWlCRHj4czs_lYgzbFRd6sztEJEyeSsseErhEeEQOScCIoMTzzUQ6RPJqMiTSvTmxiTwjgUPOfCLksZy2ueXYdd2tnq7WwBZhVl_U3WL2srsubt1w1D4WxHXfxUan0_ohf1IXjrBNguXn66sEDFnRY7zXfvFGEW5z6NcHV8xh5q7gHcrBrDEZAO-8NqAHrhY4q3V1-ubpm2Nxs8vrW3uAKbMuiiNTJrqP7jXYYlkT6gHq6PVDNNuTCddkwvMRBjLhA5nwnky4IRPekwkbMmGJj8j0CEWjIPJDq2m2Ya2F2FqMMlsNeO6ac-iMscTTbj-DgXE94KAWE9vTeZ7TPE8T7VCaUJUyZju2Ep7JrXqMTtblWj9BmGsxyDOeZYJq0BBcOZp7mdKKK5oq7T1Fp_DXP6WFGcEBqYKhprOBy4x3Qp_94f3n6G5dQ9jEwV6gk-1mp0_BMtyqlxUiPwBfzknj
linkProvider Colorado Alliance of Research Libraries
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=CLINICAL+VALUES+OF+THE+FUNCTIONAL+SHOULDER+COMPLEX+MEASURED+WITH+A+DYNAMOMETER&rft.jtitle=Journal+of+The+Showa+Medical+Association&rft.au=UCHIKAWA+Tomoyoshi&rft.au=TSUTSUI+Hiroaki&rft.au=MIHARA+Kenichi&rft.au=HOKARI+Shigeru&rft.date=1997&rft.pub=%E6%98%AD%E5%92%8C%E5%A4%A7%E5%AD%A6%E5%AD%A6%E5%A3%AB%E4%BC%9A&rft.issn=0037-4342&rft.eissn=2185-0976&rft.volume=57&rft.issue=3&rft.spage=293&rft.epage=297&rft_id=info:doi/10.14930%2Fjsma1939.57.293&rft.externalDocID=130001824501
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0037-4342&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0037-4342&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0037-4342&client=summon