충남 석탄화력발전소 주변 지역 대기오염 영향 분석
In this study, we analyzed the impact of air pollutants caused by a coal-fired power plants located in Chungnam. The Chungnam region is characterized by diverse large-scale emission facilities, particularly notable for coal-fired power plants emitting noteworthy quantities of air pollutants, includi...
Saved in:
Published in | 한국대기환경학회지(국문) Vol. 40; no. 1; pp. 149 - 165 |
---|---|
Main Authors | , , , , , , , , , |
Format | Journal Article |
Language | Korean |
Published |
한국대기환경학회
01.02.2024
|
Subjects | |
Online Access | Get full text |
ISSN | 1598-7132 2383-5346 |
DOI | 10.5572/KOSAE.2024.40.1.149 |
Cover
Abstract | In this study, we analyzed the impact of air pollutants caused by a coal-fired power plants located in Chungnam.
The Chungnam region is characterized by diverse large-scale emission facilities, particularly notable for coal-fired power plants emitting noteworthy quantities of air pollutants, including PM2.5, SO2, and NO2. For the analysis, we conducted modeling using the WRF-SMOKE-CMAQ system, utilizing emission data from the Clean Air Policy Support System (CAPSS) in 2019 was used. The modeling focused on Boryeong, Dangjin, and Taean, where coal-fired power plants are situated. To assess changes in concentration resulting from emission variations, the study used the Brute Force Method (BFM) and the Significant Impact Levels (SILs), developed by the United States Environmental Protection Agency (EPA). As a result of the emission analysis, it was found that air pollutant emissions in Chungnam were gradually decreasing, with significant reductions noted in Dangjin, Boryeong, and Taean. Analyzing the influence of surrounding areas on the modeling target areas revealed that the impact in Dangjin and Taean was relatively small, likely due to the wind trajectory being pushed from inland to the coast.
Conversely, Boryeong had the most significant influence on its surrounding areas, with the most affected regions being Boryeong, Hongseong, and Yesan. KCI Citation Count: 1 |
---|---|
AbstractList | In this study, we analyzed the impact of air pollutants caused by a coal-fired power plants located in Chungnam.
The Chungnam region is characterized by diverse large-scale emission facilities, particularly notable for coal-fired power plants emitting noteworthy quantities of air pollutants, including PM2.5, SO2, and NO2. For the analysis, we conducted modeling using the WRF-SMOKE-CMAQ system, utilizing emission data from the Clean Air Policy Support System (CAPSS) in 2019 was used. The modeling focused on Boryeong, Dangjin, and Taean, where coal-fired power plants are situated. To assess changes in concentration resulting from emission variations, the study used the Brute Force Method (BFM) and the Significant Impact Levels (SILs), developed by the United States Environmental Protection Agency (EPA). As a result of the emission analysis, it was found that air pollutant emissions in Chungnam were gradually decreasing, with significant reductions noted in Dangjin, Boryeong, and Taean. Analyzing the influence of surrounding areas on the modeling target areas revealed that the impact in Dangjin and Taean was relatively small, likely due to the wind trajectory being pushed from inland to the coast.
Conversely, Boryeong had the most significant influence on its surrounding areas, with the most affected regions being Boryeong, Hongseong, and Yesan. KCI Citation Count: 1 |
Author | 노수진(Sujin Noh) 이가혜(Gahye Lee) 이상신(Sang Sin Lee) 박세찬(Sechan Park) 박선환(Sunhwan Park) 최영남(Young-Nam Choi) 김수향(Su-Hyang Kim) 김정호(Jeongho Kim) 황규철(Kyucheol Hwang) 김종범(Jong Bum Kim) |
Author_xml | – sequence: 1 fullname: 김수향(Su-Hyang Kim) – sequence: 2 fullname: 박세찬(Sechan Park) – sequence: 3 fullname: 황규철(Kyucheol Hwang) – sequence: 4 fullname: 최영남(Young-Nam Choi) – sequence: 5 fullname: 이상신(Sang Sin Lee) – sequence: 6 fullname: 박선환(Sunhwan Park) – sequence: 7 fullname: 이가혜(Gahye Lee) – sequence: 8 fullname: 김정호(Jeongho Kim) – sequence: 9 fullname: 노수진(Sujin Noh) – sequence: 10 fullname: 김종범(Jong Bum Kim) |
BackLink | https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART003051485$$DAccess content in National Research Foundation of Korea (NRF) |
BookMark | eNotjL1Kw1AARi9SwVr7BC5ZXITE-39vxlKjFosFzR6S9EZCNZUUB7eqwamj2AoKBS3qIBSE4tAnMrfvYNBO5xvO-dZBKekmCoBNBC3GBN45bJ3UHAtDTC0KLWQhaq-AMiaSmIxQXgJlxGxpCkTwGqj2enEAKRWUSszKwNGzj_zm3dDZ8-I2Wzze5-NJPn3S40zfDQz9Ms-_-oZ-6-vhp5EP-j_fUz161cO5oUfXi4eJkc-yIt0Aq5F_1lPVJSvA3XPc-oHZbO036rWmmXBGTCygQlww5XPOFG37TNkBlLbCbYglDFEkKaY4KhhQElKMoApFGEiJOSE-JBWw_X-bpJHXCWOv68d_PO16ndSrHbsND0EiJeeikLeW8mUan6t27HsXxfDTK--otesgJBCXkpBfA-5xnQ |
ContentType | Journal Article |
DBID | DBRKI TDB ACYCR |
DOI | 10.5572/KOSAE.2024.40.1.149 |
DatabaseName | DBPIA - 디비피아 DBpia Journals Korean Citation Index |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
DocumentTitleAlternate | Air Pollution Impact in the Area Around Coal-fired Power Plant in ChungNam |
DocumentTitle_FL | Air Pollution Impact in the Area Around Coal-fired Power Plant in ChungNam |
EISSN | 2383-5346 |
EndPage | 165 |
ExternalDocumentID | oai_kci_go_kr_ARTI_10388667 NODE11716883 |
GroupedDBID | .UV ALMA_UNASSIGNED_HOLDINGS DBRKI TDB ACYCR |
ID | FETCH-LOGICAL-n653-270e1675ea665e4da5e9b089e2d0280c1f84242f1f8b43c4210ec7cb882633a03 |
ISSN | 1598-7132 |
IngestDate | Sat Aug 02 03:10:35 EDT 2025 Thu Feb 06 13:57:08 EST 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 1 |
Keywords | NO 2.5< Coal-fired power plant BFM PM< SILs SO SUB> Chungnam |
Language | Korean |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-n653-270e1675ea665e4da5e9b089e2d0280c1f84242f1f8b43c4210ec7cb882633a03 |
Notes | https://doi.org/10.5572/KOSAE.2024.40.1.149 |
PageCount | 17 |
ParticipantIDs | nrf_kci_oai_kci_go_kr_ARTI_10388667 nurimedia_primary_NODE11716883 |
PublicationCentury | 2000 |
PublicationDate | 2024-02 |
PublicationDateYYYYMMDD | 2024-02-01 |
PublicationDate_xml | – month: 02 year: 2024 text: 2024-02 |
PublicationDecade | 2020 |
PublicationTitle | 한국대기환경학회지(국문) |
PublicationYear | 2024 |
Publisher | 한국대기환경학회 |
Publisher_xml | – name: 한국대기환경학회 |
SSID | ssib044744825 ssib053377207 ssib012146244 ssib036279052 ssib005299985 ssib001107110 ssib006781219 |
Score | 2.2617235 |
Snippet | In this study, we analyzed the impact of air pollutants caused by a coal-fired power plants located in Chungnam.
The Chungnam region is characterized by... |
SourceID | nrf nurimedia |
SourceType | Open Website Publisher |
StartPage | 149 |
SubjectTerms | 대기과학 |
Title | 충남 석탄화력발전소 주변 지역 대기오염 영향 분석 |
URI | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE11716883 https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART003051485 |
Volume | 40 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
ispartofPNX | 한국대기환경학회지, 2024, 40(1), , pp.149-165 |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV3NaxNBFB_aetCLKCrWj7KgcyqJ-zGzO3Pc3axUhfZghN5Ckt0VCSQlJBcPEjV46lFsBYVCLepBKAjFQ_8is_kffG92ml1LkCpeNsPb9968eW8383vD7BtC7trSjD2bQwTspl2Bh8KuyDSNK8xzmx6LpYhTtct33V17wh5u8s2Fxf3SrqXhoFVtP5_7Xcm_RBVoEFf8SvYvIjtTCgRoQ3zhChGG65liTKOQBi71JY0CKmzqi1UkCUZljUY1KhxsQ0NKKhky-Sb1OTYCk8oQmYGCPCDlUhEqed-hQaiYQN7MSR5uiYCG9KhfW1X9hYrk00CgNrwnqM80U5CrApKwlAVgJldyYLDuEM0sg2PFx5VdoJVDR_P6yUcjFMWmQe1ESqqGj_wzg-H5YSaWoioteChBqYcjhFKl7StYcgdxbSb0jJ4G34UFi7IDXQ_qPO1MMMg3C5YQR5Hf0Y7QYSqvtdjsZHu2fjv-lxvK8w2Wc7X0Em-iaACinAp3WHlesfK6rhqiWPnxGqdnP849rKb7aOOxH1XR_CqDKbE6ky3XGj-FAX6rNt5pP2s87TU6_QbkVA8aWEJfuK63SM7ZHgBU3B_7IiowtwUotYQhOQAcWSqIBGjIsouagRaeJF_ClACgsEbcDGMz5jEmikkG0hFIAFXZg5mz8uphONx7cwYLKLHbB3B5vjvEEzLgb7aEGOuXyEWd6hl-_t5eJgud3hUSZUdfJ6--GNn44_T1ePr-7WTvYHL4IdsbZ2-2jWz_ePJ9ZGSfR9nON2OyPfr54zDb_ZTtHBvZ7svpuwNjcjQG0aukfj-qh2sVfZRJpetyBz_6TCxIzZOm6_KExU2eyJYpZGLHuLWhbaWCAVZO4bfFnDazLTNpe-0WpL-u4zRN5xpZ6va6yXVipKl0U0hakpbrMEzvYMIFD_IYkH9TxvEyuQOjVzH8QyyXycrMO42tvK5NY32jFllYPksI58aZ1NwkF4rX5BZZGvSHyW0A6YPWinpIfgG2aK4E |
linkProvider | ISSN International Centre |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=%EC%B6%A9%EB%82%A8+%EC%84%9D%ED%83%84%ED%99%94%EB%A0%A5%EB%B0%9C%EC%A0%84%EC%86%8C+%EC%A3%BC%EB%B3%80+%EC%A7%80%EC%97%AD+%EB%8C%80%EA%B8%B0%EC%98%A4%EC%97%BC+%EC%98%81%ED%96%A5+%EB%B6%84%EC%84%9D&rft.jtitle=%ED%95%9C%EA%B5%AD%EB%8C%80%EA%B8%B0%ED%99%98%EA%B2%BD%ED%95%99%ED%9A%8C%EC%A7%80%2C+40%281%29&rft.au=%EA%B9%80%EC%88%98%ED%96%A5&rft.au=%EB%B0%95%EC%84%B8%EC%B0%AC&rft.au=%ED%99%A9%EA%B7%9C%EC%B2%A0&rft.au=%EC%B5%9C%EC%98%81%EB%82%A8&rft.date=2024-02-01&rft.pub=%ED%95%9C%EA%B5%AD%EB%8C%80%EA%B8%B0%ED%99%98%EA%B2%BD%ED%95%99%ED%9A%8C&rft.issn=1598-7132&rft.eissn=2383-5346&rft.spage=149&rft.epage=165&rft_id=info:doi/10.5572%2FKOSAE.2024.40.1.149&rft.externalDBID=n%2Fa&rft.externalDocID=oai_kci_go_kr_ARTI_10388667 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1598-7132&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1598-7132&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1598-7132&client=summon |