의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구
There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging check...
Saved in:
| Published in | 방사선기술과학 Vol. 38; no. 4; pp. 389 - 394 |
|---|---|
| Main Authors | , , |
| Format | Journal Article |
| Language | Korean |
| Published |
대한방사선과학회(구 대한방사선기술학회)
30.12.2015
KOREAN SOCIETY OF RADIOLOGICAL TECHNOLOGY 대한방사선과학회 |
| Subjects | |
| Online Access | Get full text |
| ISSN | 2288-3509 2384-1168 |
| DOI | 10.17946/JRST.2015.38.4.08 |
Cover
| Abstract | There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are $120{\times}150{\times}190mm$, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination. 의료영상 검사는 정보기술 및 의료장비의 발달로 인체의 해부학적 구조를 묘사하는 능력이 날로 발전하고 있다. 그러나 상지회전이 필요한 어깨관절 의료영상 검사에서는 인체구조의 복잡성으로 정확한 자세유지가 의료영상의 진단적 가치에 매우 중요하다. 자기공명검사의 경우 긴 검사시간과 고정된 자세가 필요해 검사자의 노력과 환자의 의지만으로 재현성 있는 검사가 불가능하다. 이에 상지회전과 정량적 각도가 가능한 보조기구를 개발하여 진단적 가치가있는 의료영상 검사를 하고자하였다. 본 연구는 선행 연구의 결과를 바탕으로 보조기구를 제작하였으며, 공학용 프로그램인 CATIA 프로그램으로 3차원 모델링을 설계하여, 3D프린터로 최종 완성된 보조기구를 제작하였다. 사용된 3D 프린터는 Stratasys Objet350 Connex 모델이며, 재질은 광경화성 수지를 사용하였다. 완성된 보조기구의 크기는 $120{\times}150{\times}190mm$이며, 손잡이부의 내경은 125.9 mm 로 디자인되었다. 보조기구는 총 4개의 부품으로 바디부(외부), 손잡이부(내부), 고정단자, 연결부로 구성되었으며 바디부와 손잡이부는 원활한 회전이 가능하도록 2.1 mm의 유격이 유지되도록 하였다. 손잡이부에는 360o 눈금선을 표시하여 환자마다 관찰에 필요한 회전각도를 기록할 수 있도록 하여 추적검사나 양쪽검사에 적용할 수 있도록 하였다. |
|---|---|
| AbstractList | There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are $120{\times}150{\times}190mm$, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination. 의료영상 검사는 정보기술 및 의료장비의 발달로 인체의 해부학적 구조를 묘사하는 능력이 날로 발전하고 있다. 그러나 상지회전이 필요한 어깨관절 의료영상 검사에서는 인체구조의 복잡성으로 정확한 자세유지가 의료영상의 진단적 가치에 매우 중요하다. 자기공명검사의 경우 긴 검사시간과 고정된 자세가 필요해 검사자의 노력과 환자의 의지만으로 재현성 있는 검사가 불가능하다. 이에 상지회전과 정량적 각도가 가능한 보조기구를 개발하여 진단적 가치가있는 의료영상 검사를 하고자하였다. 본 연구는 선행 연구의 결과를 바탕으로 보조기구를 제작하였으며, 공학용 프로그램인 CATIA 프로그램으로 3차원 모델링을 설계하여, 3D프린터로 최종 완성된 보조기구를 제작하였다. 사용된 3D 프린터는 Stratasys Objet350 Connex 모델이며, 재질은 광경화성 수지를 사용하였다. 완성된 보조기구의 크기는 $120{\times}150{\times}190mm$이며, 손잡이부의 내경은 125.9 mm 로 디자인되었다. 보조기구는 총 4개의 부품으로 바디부(외부), 손잡이부(내부), 고정단자, 연결부로 구성되었으며 바디부와 손잡이부는 원활한 회전이 가능하도록 2.1 mm의 유격이 유지되도록 하였다. 손잡이부에는 360o 눈금선을 표시하여 환자마다 관찰에 필요한 회전각도를 기록할 수 있도록 하여 추적검사나 양쪽검사에 적용할 수 있도록 하였다. 의료영상 검사는 정보기술 및 의료장비의 발달로 인체의 해부학적 구조를 묘사하는 능력이 날로 발전하고 있다. 그러나 상지회전이 필요한 어깨관절 의료영상 검사에서는 인체구조의 복잡성으로 정확한 자세유지가 의료영상의 진단적 가치에 매우 중요하다. 자기공명검사의 경우 긴 검사시간과 고정된 자세가 필요해 검사자의 노력과 환자의 의지만으로 재현성 있는 검사가 불가능하다. 이에 상지회전과 정량적 각도가 가능한 보조기구를 개발하여 진단적 가치가있는 의료영상 검사를 하고자하였다. 본 연구는 선행 연구의 결과를 바탕으로 보조기구를 제작하였으며, 공학용 프로그램인 CATIA 프로그램으로 3차원 모델링을 설계하여, 3D프린터로 최종 완성된 보조기구를 제작하였다. 사용된 3D 프린터는 Stratasys Objet350 Connex 모델이며, 재질은 광경화성 수지를 사용하였다. 완성된 보조기구의 크기는 120 X 150 X 190 mm 이며, 손잡이부의 내경은 125.9 mm 로 디자인되었다. 보조기구는 총 4개의 부품으로 바디부(외부), 손잡이부(내부), 고정단자, 연결부로 구성되었으며 바디부와 손잡이부는 원활한 회전이 가능하도록 2.1 mm의 유격이 유지되도록 하였다. 손잡이부에는 360o 눈금선을 표시하여 환자마다 관찰에 필요한 회전각도를 기록할 수 있도록 하여 추적검사나 양쪽검사에 적용할 수 있도록 하였다. There is a progressive development in the medical imaging technology, especially of descriptive capa-bility for anatomical structure of human body thanks to advancement of information technology and medi-cal devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cas-es of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are 120 X 150 X 190 mm, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be re-corded per patient for traceability and dual examination. KCI Citation Count: 14 |
| Author | 최성대(Seong Dae Choi) 김형균(Hyeong Gyun Kim) 윤재호(Jae Ho Yoon) |
| Author_xml | – sequence: 1 fullname: 김형균(Hyeong Gyun Kim) – sequence: 2 fullname: 윤재호(Jae Ho Yoon) – sequence: 3 fullname: 최성대(Seong Dae Choi) |
| BackLink | https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002065903$$DAccess content in National Research Foundation of Korea (NRF) |
| BookMark | eNpNkDtLA0EUhQdRUKN_wGobwWbXmbmz8yiDz0QhoOmHfczKsmEXsjZ2PlLaCIopoiiiNhbBB1j4i5LJfzBRC-HCdzj33FPceTSdF7lBaIlgjwjF-Gp9b7_pUUx8D6THPCyn0BwFyVxCuJweayqlCz5Ws2ixLNMQA6dCcurPoYa96Q4fzm33xJ6dOIPXY3v6Mnz8cmyvM7rqOWPTPh87w7d3e98ffPYHHy_jAwfWndFlZ_jUH3X6jr3r2dsLx15PtgtoJglapVn8YwU1Nzeaa9vubmOrtlbddTMF3CUhTSiwOOAxZ7E0EU1imfCIJMADpSQoowTERmJhWMTjQPnUVyDCxMRJxAAqaOW3Nm8nOotSXQTpDw8KnbV1da9Z01RwGE8FLf9Gs7Q8THUely1dr-40Jv_CHDhQRRij_3JHRVjosCiyyOSHpq0ZJhhTJgRnWMA3JVuB3A |
| ContentType | Journal Article |
| Copyright | COPYRIGHT(C) KYOBO BOOK CENTRE ALL RIGHTS RESERVED |
| Copyright_xml | – notice: COPYRIGHT(C) KYOBO BOOK CENTRE ALL RIGHTS RESERVED |
| DBID | P5Y SSSTE JDI ACYCR |
| DEWEY | 616.0757 |
| DOI | 10.17946/JRST.2015.38.4.08 |
| DatabaseName | Kyobo Scholar Journals Scholar(스콜라) KoreaScience Korean Citation Index |
| DatabaseTitleList | |
| DeliveryMethod | fulltext_linktorsrc |
| Discipline | Medicine |
| DocumentTitleAlternate | Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test |
| EISSN | 2384-1168 |
| EndPage | 394 |
| ExternalDocumentID | oai_kci_go_kr_ARTI_276376 JAKO201506363291442 4010024776407 |
| GroupedDBID | ALMA_UNASSIGNED_HOLDINGS P5Y SSSTE .UV JDI ACYCR |
| ID | FETCH-LOGICAL-k936-1b2f234da6d64d8ec2fd8f6c1f36a99839e973de807e4c6da9525937bfedfc433 |
| ISSN | 2288-3509 |
| IngestDate | Sun Aug 18 03:10:33 EDT 2024 Fri Dec 22 12:00:39 EST 2023 Tue Feb 18 15:06:42 EST 2025 |
| IsDoiOpenAccess | true |
| IsOpenAccess | true |
| IsPeerReviewed | false |
| IsScholarly | false |
| Issue | 4 |
| Keywords | 3D모델링 3D modeling 보조기구 Auxiliary device Medical imaging 3D프린터 의료영상 3D printer 3D |
| Language | Korean |
| LinkModel | OpenURL |
| MergedId | FETCHMERGED-LOGICAL-k936-1b2f234da6d64d8ec2fd8f6c1f36a99839e973de807e4c6da9525937bfedfc433 |
| Notes | KISTI1.1003/JNL.JAKO201506363291442 G704-001962.2015.38.4.016 |
| OpenAccessLink | http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201506363291442&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 |
| PageCount | 6 |
| ParticipantIDs | nrf_kci_oai_kci_go_kr_ARTI_276376 kisti_ndsl_JAKO201506363291442 kyobo_bookcenter_4010024776407 |
| PublicationCentury | 2000 |
| PublicationDate | 2015-12-30 |
| PublicationDateYYYYMMDD | 2015-12-30 |
| PublicationDate_xml | – month: 12 year: 2015 text: 2015-12-30 day: 30 |
| PublicationDecade | 2010 |
| PublicationTitle | 방사선기술과학 |
| PublicationTitleAlternate | Journal of radiological science and technology |
| PublicationYear | 2015 |
| Publisher | 대한방사선과학회(구 대한방사선기술학회) KOREAN SOCIETY OF RADIOLOGICAL TECHNOLOGY 대한방사선과학회 |
| Publisher_xml | – name: 대한방사선과학회(구 대한방사선기술학회) – name: KOREAN SOCIETY OF RADIOLOGICAL TECHNOLOGY – name: 대한방사선과학회 |
| SSID | ssib036278625 ssib053376989 ssib030194475 ssib023718648 |
| Score | 1.5919192 |
| Snippet | There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to... 의료영상 검사는 정보기술 및 의료장비의 발달로 인체의 해부학적 구조를 묘사하는 능력이 날로 발전하고 있다. 그러나 상지회전이 필요한 어깨관절 의료영상 검사에서는... |
| SourceID | nrf kisti kyobo |
| SourceType | Open Website Open Access Repository Publisher |
| StartPage | 389 |
| SubjectTerms | 방사선과학 |
| TableOfContents | 국문초록 Ⅰ. 서론 Ⅱ. 실험방법 Ⅲ. 실험 결과 Ⅳ. 고찰 Ⅴ. 결론 참고문헌 Abstract |
| Title | 의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구 |
| URI | https://scholar.kyobobook.co.kr/article/detail/4010024776407 http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201506363291442&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002065903 |
| Volume | 38 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| ispartofPNX | 방사선기술과학, 2015, 38(4), , pp.389-394 |
| journalDatabaseRights | – providerCode: PRVHPJ databaseName: ROAD: Directory of Open Access Scholarly Resources customDbUrl: eissn: 2384-1168 dateEnd: 99991231 omitProxy: true ssIdentifier: ssib023718648 issn: 2288-3509 databaseCode: M~E dateStart: 20150101 isFulltext: true titleUrlDefault: https://road.issn.org providerName: ISSN International Centre |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnR3LbtNA0GrLhQsCAaI8KiPhk5Vg767t3aPtBEJRqUSDVE6WX4EqKJZCeygH1EKPXJBA9FAQCAGXHiIeEge-qHEvfAEzG8dxKRKUi7073pmdncl6ZpzdHUW5Ejki4WZMaiQ2IghQLJhzLAxrMUlSw05DHhm4UXjhlt26w-aXreWp6Z-VVUtrq1E9fvTHfSX_o1WAgV5xl-wRNFsSBQCUQb9wBQ3D9Z90rDV9TTQ0wbWmp7lU476EcHAPscABYupa09U8uaIBQURzfdna0jxfl80ByrQmkLGgrJeIWHAdwNOxvUc1j0mQqXmGpMnHBUvSLFjRaUOX1JgkCz3Zsl0Dq54h6bsG9ooYTU2YIy6cKrWqyyx7NzRXVPiXLLtVNgDCxxBg1R8PqPzOIZ8IKQYpMXiIEAeRCG-tp5h06fr6Wk-XCaYreFJELiv4df2CAHRM-HyY6q1Mv5uhB30Ax7OKMeKwTRwEaAcXWvIl2VUDMP372coYrfjyYlryfEejnCsTzLGK_iaQA8OXBRcpEF6KVz860d-kfJi6mJgUQmAGUcsQVftHeWWes4oxo6PkToVfREfJqA-ZXMxQgOnEby-1caWkVae8zuoGnzgY5bJPiOXRJ3Qc_Pd4WjlGwBJjupWFx82xDSAUnCV7EqKD_RF4JmVZt4kDQXhZh2jFwRyomENyPLhibxwydvUQWxCEYmS2gvf1LMrAp-z1OxWfsn1SOVEEg6o7mtmnlKludlpZzF9vD98_y7c386eb6t7njfzJ7vDDDzXf2dp_uaMCMP-0oQ6_fM3fDfa-D_a-7QKCShvq_out4cfB_tZAzd_u5G-eq_krfHpGaV9rtv1WrUh7UusKatfMiHQIZUloJzZLeBqTTsI7dmx2qB0KAQFNKhyapNxwUhbbSSgsYkGQEXXSpBMzSs8qM72sl55TVCYgujOBTgRRTwhvXpPEccwjakNbeHfPKnNSFkEvefggmHdvLhJ54ii1KREmYwQboJACjPhxtXjaDw4ocVa5DNILuvFKgOfU4_1eFnT7AUTjNwLQL2jn_N-IXFCOT6bXRWVmtb-WXgJXfzWak7-NX9KhwvU |
| linkProvider | ISSN International Centre |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=%EC%9D%98%EB%A3%8C%EC%98%81%EC%83%81+%EA%B2%80%EC%82%AC%EB%A5%BC+%EC%9C%84%ED%95%9C+%EC%83%81%EC%A7%80+%EB%B3%B4%EC%A1%B0%EA%B8%B0%EA%B5%AC%EC%9D%98+3D+%ED%94%84%EB%A6%B0%ED%84%B0+%EC%A0%9C%EC%9E%91+%EC%97%B0%EA%B5%AC&rft.jtitle=%EB%B0%A9%EC%82%AC%EC%84%A0%EA%B8%B0%EC%88%A0%EA%B3%BC%ED%95%99&rft.au=%EA%B9%80%ED%98%95%EA%B7%A0%28Hyeong+Gyun+Kim%29&rft.au=%EC%9C%A4%EC%9E%AC%ED%98%B8%28Jae+Ho+Yoon%29&rft.au=%EC%B5%9C%EC%84%B1%EB%8C%80%28Seong+Dae+Choi%29&rft.date=2015-12-30&rft.pub=%EB%8C%80%ED%95%9C%EB%B0%A9%EC%82%AC%EC%84%A0%EA%B3%BC%ED%95%99%ED%9A%8C%28%EA%B5%AC+%EB%8C%80%ED%95%9C%EB%B0%A9%EC%82%AC%EC%84%A0%EA%B8%B0%EC%88%A0%ED%95%99%ED%9A%8C%29&rft.issn=2288-3509&rft.volume=38&rft.issue=4&rft.spage=389&rft.epage=394&rft_id=info:doi/10.17946%2FJRST.2015.38.4.08&rft.externalDocID=4010024776407 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2288-3509&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2288-3509&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2288-3509&client=summon |