화력 발전기 보일러 내부 작업자 위치 모니터링 시스템 개발

There are regularly planned overhaul periods in thermal power plants, which involve the maintenance of the boiler of the power plants. However, thermal power plants workers are always exposed to risk during overhaul periods owing to the narrow space and significant dust inside the boiler. Therefore,...

Full description

Saved in:
Bibliographic Details
Published in한국안전학회지 Vol. 36; no. 5; pp. 71 - 78
Main Authors 송규, K. Song, 윤찬녕, C. N. Yun, 신영하, Y. H. Shin, 신정훈, J. H. Shin, 한성희, S. H. Han, 장동영, D. Y. Jang
Format Journal Article
LanguageKorean
Published 한국안전학회 31.10.2021
Subjects
Online AccessGet full text
ISSN1738-3803
2383-9953

Cover

Abstract There are regularly planned overhaul periods in thermal power plants, which involve the maintenance of the boiler of the power plants. However, thermal power plants workers are always exposed to risk during overhaul periods owing to the narrow space and significant dust inside the boiler. Therefore, it is essential to develop a safety monitoring system that is suitable for operating in this type of environment. In this study, we developed not only a worker three-dimensional (3D)-location monitoring system that can monitor and record the entry/exit of workers, their 3D-location, and fall accidents but also a method to secure the working environment and operation efficiency. This system comprises of a worker tag, which was equipped with an inertial measurement unit, a barometric pressure sensor, and a Bluetooth low energy (BLE), and the tags were given to each worker. In addition, the location of workers inside the boiler was measured using a pedestrian dead reckoning (PDR) method and BLE beacons. The location data of the workers tag were transmitted to the integrated database (DB) server through a gateway, and to the administrator monitoring system. The performance of the system was demonstrated inside an actual thermal power plant boiler, and the accuracy and reliability of the system were verified through a number of repeated tests. These results provide insights on designing a new system for monitoring enclosed spaces.
AbstractList There are regularly planned overhaul periods in thermal power plants, which involve the maintenance of the boiler of the power plants. However, thermal power plants workers are always exposed to risk during overhaul periods owing to the narrow space and significant dust inside the boiler. Therefore, it is essential to develop a safety monitoring system that is suitable for operating in this type of environment. In this study, we developed not only a worker three-dimensional (3D)-location monitoring system that can monitor and record the entry/exit of workers, their 3D-location, and fall accidents but also a method to secure the working environment and operation efficiency. This system comprises of a worker tag, which was equipped with an inertial measurement unit, a barometric pressure sensor, and a Bluetooth low energy (BLE), and the tags were given to each worker. In addition, the location of workers inside the boiler was measured using a pedestrian dead reckoning (PDR) method and BLE beacons. The location data of the workers tag were transmitted to the integrated database (DB) server through a gateway, and to the administrator monitoring system. The performance of the system was demonstrated inside an actual thermal power plant boiler, and the accuracy and reliability of the system were verified through a number of repeated tests. These results provide insights on designing a new system for monitoring enclosed spaces.
There are regularly planned overhaul periods in thermal power plants, which involve the maintenance of the boiler of the power plants. However, thermal power plants workers are always exposed to risk during overhaul periods owing to the narrow space and significant dust inside the boiler. Therefore, it is essential to develop a safety monitoring system that is suitable for operating in this type of environment. In this study, we developed not only a worker three-dimensional (3D)-location monitoring system that can monitor and record the entry/exit of workers, their 3D-location, and fall accidents but also a method to secure the working environment and operation efficiency. This system comprises of a worker tag, which was equipped with an inertial measurement unit, a barometric pressure sensor, and a Bluetooth low energy (BLE), and the tags were given to each worker. In addition, the location of workers inside the boiler was measured using a pedestrian dead reckoning (PDR) method and BLE beacons. The location data of the workers tag were transmitted to the integrated database (DB) server through a gateway, and to the administrator monitoring system. The performance of the system was demonstrated inside an actual thermal power plant boiler, and the accuracy and reliability of the system were verified through a number of repeated tests. These results provide insights on designing a new system for monitoring enclosed spaces. KCI Citation Count: 0
Author S. H. Han
송규
신영하
D. Y. Jang
신정훈
윤찬녕
Y. H. Shin
K. Song
J. H. Shin
한성희
장동영
C. N. Yun
Author_xml – sequence: 1
  fullname: 송규
– sequence: 2
  fullname: K. Song
– sequence: 3
  fullname: 윤찬녕
– sequence: 4
  fullname: C. N. Yun
– sequence: 5
  fullname: 신영하
– sequence: 6
  fullname: Y. H. Shin
– sequence: 7
  fullname: 신정훈
– sequence: 8
  fullname: J. H. Shin
– sequence: 9
  fullname: 한성희
– sequence: 10
  fullname: S. H. Han
– sequence: 11
  fullname: 장동영
– sequence: 12
  fullname: D. Y. Jang
BackLink https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002770950$$DAccess content in National Research Foundation of Korea (NRF)
BookMark eNo9zD1Lw0AcgPFDKlhrP4HLLQ4OgeT-udzdWIov1UJFuh9JmkhoTSVxcVOpIHZREFSItYOiiEPAIgp-ot71O1isOD3Lj2cRFeJuHMyhIgEOhhAUCqhoMeAGcBMWUDlNI8-kAIwBkCLamdxdq-ETVnmmh73xZ47V-0jff6uHN6xOR-rjGOvBlb4504NLrLOe_rrF6vVF9c8nvVw9n2Ddz_TF4-Qsw-M8m16W0HzodtKg_NcSaq6vNaubRr2xUatW6kab247BiGe1qEstajMXQsvzwsAl4IfMJ77DA0bB5Cyg1LN9wQXnInBNHzw_DFsmYwRKaHW2jZNQtv1Idt3ot3td2U5kZbdZk4Izx7adqV2Z2XaUHkYybqUduVXZbhCTWGAJm5g2F5aYuuV_l8qDJNp3kyMJggCYDvwATuJ7Ig
ContentType Journal Article
DBID HZB
Q5X
JDI
ACYCR
DEWEY 363.11
DatabaseName Korea Information Science Society (KISS)
Korean Studies Information Service System (KISS) B-Type
[Open Access] KoreaScience
Korean Citation Index
DatabaseTitleList


DeliveryMethod fulltext_linktorsrc
Discipline Social Welfare & Social Work
DocumentTitleAlternate 화력 발전기 보일러 내부 작업자 위치 모니터링 시스템 개발
The Monitoring System for Location of Workers Inside a Thermal Power Plant Boiler
EISSN 2383-9953
EndPage 78
ExternalDocumentID oai_kci_go_kr_ARTI_9876446
JAKO202131942048919
3923306
GroupedDBID .UV
HZB
Q5X
JDI
ACYCR
ID FETCH-LOGICAL-k846-72b1d5a51547a3f1bbfea23cf7c2c68e753087e55b4c989889ea0c3bcffd07723
ISSN 1738-3803
IngestDate Sun Mar 09 07:54:28 EDT 2025
Fri Dec 22 12:04:05 EST 2023
Sat Sep 06 10:41:38 EDT 2025
IsOpenAccess true
IsPeerReviewed false
IsScholarly false
Issue 5
Keywords enclosed space
PDR(Pedestrian dead reckoning)
thermal power plant boiler
worker's location monitoring system
BLE(Bluetooth low energy)
Language Korean
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-k846-72b1d5a51547a3f1bbfea23cf7c2c68e753087e55b4c989889ea0c3bcffd07723
Notes Korean Society of Safety
KISTI1.1003/JNL.JAKO202131942048919
OpenAccessLink http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO202131942048919&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
PageCount 8
ParticipantIDs nrf_kci_oai_kci_go_kr_ARTI_9876446
kisti_ndsl_JAKO202131942048919
kiss_primary_3923306
PublicationCentury 2000
PublicationDate 20211031
PublicationDateYYYYMMDD 2021-10-31
PublicationDate_xml – month: 10
  year: 2021
  text: 20211031
  day: 31
PublicationDecade 2020
PublicationTitle 한국안전학회지
PublicationTitleAlternate 한국안전학회지
PublicationYear 2021
Publisher 한국안전학회
Publisher_xml – name: 한국안전학회
SSID ssib053377332
ssib012146287
ssib001535083
ssib008451743
ssib016108132
Score 1.7869563
Snippet There are regularly planned overhaul periods in thermal power plants, which involve the maintenance of the boiler of the power plants. However, thermal power...
SourceID nrf
kisti
kiss
SourceType Open Website
Open Access Repository
Publisher
StartPage 71
SubjectTerms BLE(Bluetooth low energy)
enclosed space
PDR(Pedestrian dead reckoning)
thermal power plant boiler
worker’s location monitoring system
안전공학
Title 화력 발전기 보일러 내부 작업자 위치 모니터링 시스템 개발
URI https://kiss.kstudy.com/ExternalLink/Ar?key=3923306
http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO202131942048919&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002770950
Volume 36
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
ispartofPNX 한국안전학회지, 2021, 36(5), 169, pp.71-78
journalDatabaseRights – providerCode: PRVHPJ
  databaseName: ROAD: Directory of Open Access Scholarly Resources
  customDbUrl:
  eissn: 2383-9953
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssib008451743
  issn: 1738-3803
  databaseCode: M~E
  dateStart: 20150101
  isFulltext: true
  titleUrlDefault: https://road.issn.org
  providerName: ISSN International Centre
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Pa9RAFA-1Jy-iVLH-KUGc05IlycwkM8fZdEuttHqoUE8hM5uUsrIrbffiQVS2IPaiIKiw1h4URTwsWETBT9SkX0F8M9luo_SghSU7-97LmzfzJrzf2yRvLOt6yH3lkUQ6Le4HDkmocnjaChy47pI0VDhIAv028uJSMH-HLKzQlYmJX5Wnlnqbsq4eHPteyUm8CjTwq35L9j88O1YKBGiDf-EIHobjP_kYNWcR54gT1Gwg4SJBa7rVcBGPUDPSJAY8gRoMiCUPowbRPD6LGpGm8DkkIsNjvuGBUICYFgepJuKeaYSI0UPKiBcZ7RFqgAnMaBACCWZUwYdp80ACzNEsUOCZ84BXmsdAmhghCpSaMbQ0fTSGKnI2Y6WGC2IUiVljAzX9jIdaynDTEIiVswA9j2_KmH4DJDyjJjzsRIecun5uaLUqCJ2JcoQwt8YsbSkd37ep15bqtbu9TvWvE9-rxBy92E9meCVYhBAsMHNxNZqU5VxGVw2thIZyp5m_insDOsVYV4w_hT29_8biw2YFzOI_avUzoquKj397ekt2_whcA24PQ2x25BsbBjgD0pANSLx0NrIG-KmznlXw0_JZ68wo8bFFuYrPWRPt7pR1--DNy3z3g50PB8Vuf__70M6_7hVvf-bvvtj5k7382yO72HlRvNoqdp7bxaBf_Hht558_5dtPD_rD_ONju9geFM_eH2wN7P3hALSct5bnmsvRvDPa48NpA_J1Ql96LZoAqCZhgjNPyixNfKyyUPkqYCkk0y4LU0olUXqnU8bTxFVYqixruZAY4gvWZKfbSS9aNgDRIAg5lTJNiC9dnnLpK-nzzMdSBmramtJzEd8vq7jEo6mftmbM3MSd1sa9eEHcvKVXCgQmoktac49PW9dg0uK2Wot1KXb9vdqN2-sxJJw3Yg5ogpDg0vHKL1unj9bdFWtyc72XXgUQuylnjK9_A6VwfgE
linkProvider ISSN International Centre
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=%ED%99%94%EB%A0%A5+%EB%B0%9C%EC%A0%84%EA%B8%B0+%EB%B3%B4%EC%9D%BC%EB%9F%AC+%EB%82%B4%EB%B6%80+%EC%9E%91%EC%97%85%EC%9E%90+%EC%9C%84%EC%B9%98+%EB%AA%A8%EB%8B%88%ED%84%B0%EB%A7%81+%EC%8B%9C%EC%8A%A4%ED%85%9C+%EA%B0%9C%EB%B0%9C&rft.jtitle=%ED%95%9C%EA%B5%AD%EC%95%88%EC%A0%84%ED%95%99%ED%9A%8C%EC%A7%80&rft.au=%EC%86%A1%EA%B7%9C&rft.au=K.+Song&rft.au=%EC%9C%A4%EC%B0%AC%EB%85%95&rft.au=C.+N.+Yun&rft.date=2021-10-31&rft.pub=%ED%95%9C%EA%B5%AD%EC%95%88%EC%A0%84%ED%95%99%ED%9A%8C&rft.issn=1738-3803&rft.volume=36&rft.issue=5&rft.spage=71&rft.externalDocID=3923306
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1738-3803&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1738-3803&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1738-3803&client=summon