플레이트의 소성변형 과정이 재건술에서 플레이트 안정성에 미치는 영향
Conventional bent plate used in mandibular reconstruction surgery needs safety verification since its mechanical properties are changed due to the plastic deformation during the bending process. In this study we investigate stability of the plastically deformed plate and the plate with the same shap...
Saved in:
Published in | 한국CDE학회 논문집 Vol. 21; no. 3; pp. 234 - 241 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | Korean |
Published |
(사)한국CDE학회
2016
|
Subjects | |
Online Access | Get full text |
ISSN | 2508-4003 2508-402X |
Cover
Abstract | Conventional bent plate used in mandibular reconstruction surgery needs safety verification since its mechanical properties are changed due to the plastic deformation during the bending process. In this study we investigate stability of the plastically deformed plate and the plate with the same shape without plastic deformation through the finite element analysis(FEA). First we simulate the process of plate bending to fit the defect in patient. Then, the other plate is modelled to represent a customized plate with the same shape of the plastically deformed one, but without any residual stresses from plastic deformation. After binding these plates to the mandible, we conduct the masticatory simulation. Finally, we compare the resulting Von Mises stress of the customized plate and of the bent plate. The bent plate shows much higher stress than the customized one due to the residual stresses form the bending process. The study shows that plastic deformation in the plate may decrease the safety of the reconstruction surgery. |
---|---|
AbstractList | Conventional bent plate used in mandibular reconstruction surgery needs safety verification since its mechanical properties are changed due to the plastic deformation during the bending process. In this study we investigate stability of the plastically deformed plate and the plate with the same shape without plastic deformation through the finite element analysis(FEA). First we simulate the process of plate bending to fit the defect in patient. Then, the other plate is modelled to represent a customized plate with the same shape of the plastically deformed one, but without any residual stresses from plastic deformation. After binding these plates to the mandible, we conduct the masticatory simulation. Finally, we compare the resulting Von Mises stress of the customized plate and of the bent plate. The bent plate shows much higher stress than the customized one due to the residual stresses form the bending process. The study shows that plastic deformation in the plate may decrease the safety of the reconstruction surgery. |
Author | 이득희(Deukhee Lee) 박시명(Si Myung Park) 노건우(Gunwoo Noh) |
Author_xml | – sequence: 1 fullname: 박시명(Si Myung Park) – sequence: 2 fullname: 이득희(Deukhee Lee) – sequence: 3 fullname: 노건우(Gunwoo Noh) |
BookMark | eNpNjL1Kw1AcxYNUsNa-w10cA_97b3I_xlLrZ7FLB7eQNDcQWqM0OrgpFCmlg0OrGax0cROktEMFn6i5eQdTFHU65_A752wbhegiUhtGkdggTAvIWeHXA90yynEcemBTyjmmVtFws9Ewnfb1ZJENlnqSIH0_1L1ZOr_NkjFazT_1dJxDpF_eVrOF7k_104PuPaP_M6TH_XWtN8shSt-X-iNJByOkk7vs8XXH2AzcTqzKP1oymvu1ZvXQrDcOjqqVutlmIE1KpQVcEhEozAPeooqsE_cCwm3asrAgCqDlKc8njArMfCFdjwsmJLMZeLRk7H7ftsP4KnQiP-44x5WTBgHM8gUD2wIbi79edN0Nz5Ufus5lbtzujXPa2KsBB0wkl_QLcDF7xA |
ContentType | Journal Article |
DBID | DBRKI TDB JDI |
DEWEY | 670.285 |
DatabaseName | DBPIA - 디비피아 DBPIA KoreaScience |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
DocumentTitle_FL | On the Stability of the Permanently Bent Mini-plate in Reconstructive Surgery |
EISSN | 2508-402X |
EndPage | 241 |
ExternalDocumentID | JAKO201626360540518 NODE07012979 |
GroupedDBID | .UV DBRKI TDB JDI |
ID | FETCH-LOGICAL-k609-339407928fe17f7c3e279287bf2753c4182e00cbebd263816d89ab786896560b3 |
ISSN | 2508-4003 |
IngestDate | Fri Dec 22 11:58:41 EST 2023 Thu Feb 06 13:30:19 EST 2025 |
IsOpenAccess | true |
IsPeerReviewed | false |
IsScholarly | false |
Issue | 3 |
Keywords | Titanium plate Finite Element Analysis Mandible reconstruction Plastic deformation |
Language | Korean |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-k609-339407928fe17f7c3e279287bf2753c4182e00cbebd263816d89ab786896560b3 |
Notes | KISTI1.1003/JNL.JAKO201626360540518 |
OpenAccessLink | http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201626360540518&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 |
PageCount | 8 |
ParticipantIDs | kisti_ndsl_JAKO201626360540518 nurimedia_primary_NODE07012979 |
PublicationCentury | 2000 |
PublicationDate | 2016 |
PublicationDateYYYYMMDD | 2016-01-01 |
PublicationDate_xml | – year: 2016 text: 2016 |
PublicationDecade | 2010 |
PublicationTitle | 한국CDE학회 논문집 |
PublicationTitleAlternate | Korean Journal of Computational Design and Engineering |
PublicationYear | 2016 |
Publisher | (사)한국CDE학회 |
Publisher_xml | – name: (사)한국CDE학회 |
SSID | ssib053377134 ssib026264091 ssib044738302 ssib029071402 |
Score | 1.5935247 |
Snippet | Conventional bent plate used in mandibular reconstruction surgery needs safety verification since its mechanical properties are changed due to the plastic... |
SourceID | kisti nurimedia |
SourceType | Open Access Repository Publisher |
StartPage | 234 |
Title | 플레이트의 소성변형 과정이 재건술에서 플레이트 안정성에 미치는 영향 |
URI | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE07012979 http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201626360540518&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 |
Volume | 21 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnR3LahRBsIm5aA7iE59hDvZpWZlXz3Qf5xVCJIlghICHZWdnBkJkI7p70IMoBAkhBw9Z3YORvXgTZEkOEfyi7Ow_WNXTOzuRgNHL0FTXVFV37XRX9VZVE_IgNTMLdgmj3mpZWd02M6fe1JO4niUsywwz1o0Ec4eXV5zFp_bSOlufufCsErXU7cQPW2_OzCv5H60CDPSKWbL_oNmSKACgDfqFJ2gYnufSMY1CKsAYDGjkU0-nnNMooCKkvo1d3KP-BCJ4DVvckdjQsKlv4Gu-hcEOSIhTwQDJQ5AvkYCkYCVJSUBE1AskkiG5BMgU8LDLpUJXtEVQO49wBUmm-kp2SjhFsiYJLKix-AIlBQgQEEomDvawZOdQj1XNbQlkII2UmFEvDMJoAhSy4SkJOZOD9nF4BScPmJc_SDlVpXy-JAm48DabopTDg34L28ggpNPylhNG_NQMggx--a_RYxW8_mSjtvy6q-wKdSxT5IsW6zYYlRzccr1Yt9MqTN4cX248RWq4-sCs6i6izncLg8QsKoOdrhX-xx5eRlYueY9WURwT68ChNW5gIjxYoRjuuPw2mqy1JmCAa1-u7abATLZpKTjbdq1qaTjwCly3CNIoxwf-HDo5G3PkYruLl1HAilYxztaukMvKq9K84hO5SmY2t66RuUqtzeukOd7fGw128oOj8e5xftDX8g97-fZwdPhu3O9pJ4e_8kEPOrX86_eT4VG-M8g_f8y3v2jV17S8t4No20Po1EY_jvOf_dHuvpb3348_fbtB1haitWCxru4XqW86GPFjCVt3hcmz1HAzt2WlWEyTu3Fmgg_fssHzTnW9FadxArPJDSfhohm73OECK1bF1k0y295qp7eI5jKRxYadweap20kcN1P0y8HyT9Is0Rm7TeblTDXayavnjTN0BAjlFDZeFHVmGiurYQQ7MljkrrjzNwp3ySWEFKeD98hs52U3vQ_2cieel4r_DRmroN4 |
linkProvider | ISSN International Centre |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=%ED%94%8C%EB%A0%88%EC%9D%B4%ED%8A%B8%EC%9D%98+%EC%86%8C%EC%84%B1%EB%B3%80%ED%98%95+%EA%B3%BC%EC%A0%95%EC%9D%B4+%EC%9E%AC%EA%B1%B4%EC%88%A0%EC%97%90%EC%84%9C+%ED%94%8C%EB%A0%88%EC%9D%B4%ED%8A%B8+%EC%95%88%EC%A0%95%EC%84%B1%EC%97%90+%EB%AF%B8%EC%B9%98%EB%8A%94+%EC%98%81%ED%96%A5&rft.jtitle=%ED%95%9C%EA%B5%ADCDE%ED%95%99%ED%9A%8C%EB%85%BC%EB%AC%B8%EC%A7%91&rft.au=%EB%B0%95%EC%8B%9C%EB%AA%85&rft.au=%EC%9D%B4%EB%93%9D%ED%9D%AC&rft.au=%EB%85%B8%EA%B1%B4%EC%9A%B0&rft.au=Park%2C+Si+Myung&rft.date=2016&rft.issn=2508-4003&rft.eissn=2508-402X&rft.volume=21&rft.issue=3&rft.spage=234&rft.epage=241&rft.externalDBID=n%2Fa&rft.externalDocID=JAKO201626360540518 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2508-4003&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2508-4003&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2508-4003&client=summon |