부식성 수질제어를 위한 수질안정화 모델 개발

A diagnostic evaluation model was developed for water quality stabilization. The model is capable of not only calculating saturation indices including Langelier Saturation Index, Ryznar Stability Index, Aggressive Index, and calcium carbonate precipitation potential, but also allows calculation of t...

Full description

Saved in:
Bibliographic Details
Published in한국수처리학회지, 22(1) pp. 31 - 38
Main Authors 황병기, 우달식
Format Journal Article
LanguageKorean
Published 한국수처리학회 28.02.2014
Subjects
Online AccessGet full text
ISSN1225-7192
2289-0076

Cover

Abstract A diagnostic evaluation model was developed for water quality stabilization. The model is capable of not only calculating saturation indices including Langelier Saturation Index, Ryznar Stability Index, Aggressive Index, and calcium carbonate precipitation potential, but also allows calculation of the effects of various conditioning chemicals for the water to be stabilized. The developed model was applied to evaluate water quality parameters of raw water for corrosion control. If the water is corrosive, the water quality change of the water can be predicted according to the amount of injection of stabilizing chemicals. When of 10 mg/L as a conditioning chemical is injected, the optimum condition for the interim water is satisfied and the water turns out to be non-corrosive. In case of using for corrosion control, more than 10 mg/L is necessary to satisfy the optimum water quality condition. Conclusively, the developed program can be used as a useful tool for the decision means of operators to determine an optimum dosage of injection to stabilize a water at water treatment plant. KCI Citation Count: 0
AbstractList A diagnostic evaluation model was developed for water quality stabilization. The model is capable of not only calculating saturation indices including Langelier Saturation Index, Ryznar Stability Index, Aggressive Index, and calcium carbonate precipitation potential, but also allows calculation of the effects of various conditioning chemicals for the water to be stabilized. The developed model was applied to evaluate water quality parameters of raw water for corrosion control. If the water is corrosive, the water quality change of the water can be predicted according to the amount of injection of stabilizing chemicals. When of 10 mg/L as a conditioning chemical is injected, the optimum condition for the interim water is satisfied and the water turns out to be non-corrosive. In case of using for corrosion control, more than 10 mg/L is necessary to satisfy the optimum water quality condition. Conclusively, the developed program can be used as a useful tool for the decision means of operators to determine an optimum dosage of injection to stabilize a water at water treatment plant. KCI Citation Count: 0
Author 황병기
우달식
Author_xml – sequence: 1
  fullname: 황병기
  organization: (상명대학교)
– sequence: 2
  fullname: 우달식
  organization: (한국계면공학연구소)
BackLink https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001857017$$DAccess content in National Research Foundation of Korea (NRF)
BookMark eNo1jMtKw0AUQAepYKz9h2xdBObeycxkNkIpPgoFQbIPM0lGQiSB5gdcdFEQd0YUIrgRxVUFERd-kZn-g-JjdeAcONtkUNVVvkE8xEgFlEoxIB4g8kCCwi0yaprCUOQMGVDpkb3-7dxd3LnFi--WN-5x6e47d_3aP3z4rlus2-5ft9-lXd9e-f3zU3_57n-uun7V7ZBNq8-afPTHIYkP9uPJUTA7PpxOxrOg5CEGyI2WYJm2EQgQIkMeoWbGCKtSk0LGFJOUUcpTMEalFjMIAUJNpdFK5WxIdn-31dwmZVoktS5-eFon5TwZn8TTBJCGXCD7AoeuW2o
ContentType Journal Article
DBID ACYCR
DatabaseName Korean Citation Index
DatabaseTitleList
DeliveryMethod fulltext_linktorsrc
DocumentTitleAlternate Development of Water Quality Stabilization Model using Numerical Analysis Method for Controlling Corrosivity
EISSN 2289-0076
EndPage 38
ExternalDocumentID oai_kci_go_kr_ARTI_1204562
GroupedDBID ACYCR
ALMA_UNASSIGNED_HOLDINGS
M~E
ID FETCH-LOGICAL-k542-25ba71f3af816166d2582a3bb6f9cbc1d393703005c1bb9cf2d14114a07ba99e3
ISSN 1225-7192
IngestDate Sun Mar 09 07:51:20 EDT 2025
IsPeerReviewed true
IsScholarly true
Language Korean
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-k542-25ba71f3af816166d2582a3bb6f9cbc1d393703005c1bb9cf2d14114a07ba99e3
Notes G704-001415.2014.22.1.006
PageCount 8
ParticipantIDs nrf_kci_oai_kci_go_kr_ARTI_1204562
PublicationCentury 2000
PublicationDate 20140228
PublicationDateYYYYMMDD 2014-02-28
PublicationDate_xml – month: 02
  year: 2014
  text: 20140228
  day: 28
PublicationDecade 2010
PublicationTitle 한국수처리학회지, 22(1)
PublicationYear 2014
Publisher 한국수처리학회
Publisher_xml – name: 한국수처리학회
SSID ssib025323107
ssib009283292
ssib022238404
ssib001149567
ssib001509289
Score 1.8782171
Snippet A diagnostic evaluation model was developed for water quality stabilization. The model is capable of not only calculating saturation indices including...
SourceID nrf
SourceType Open Website
StartPage 31
SubjectTerms 토목공학
Title 부식성 수질제어를 위한 수질안정화 모델 개발
URI https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001857017
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
ispartofPNX 한국수처리학회지, 2014, 22(1), , pp.31-38
journalDatabaseRights – providerCode: PRVHPJ
  databaseName: ROAD: Directory of Open Access Scholarly Resources
  customDbUrl:
  eissn: 2289-0076
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssib025323107
  issn: 1225-7192
  databaseCode: M~E
  dateStart: 19930101
  isFulltext: true
  titleUrlDefault: https://road.issn.org
  providerName: ISSN International Centre
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Pi9QwFA87C4IXWVHxP0XMaenSpE2aXIS2M7IKehphb0PTTkUGZmCYvexBPOxhYfHmiMIIXkTxtIKIBz-R0_0OvpfObDviwqqX8iN9fe81L6Tvpcl7hNyFqMdjRho3EKl0g5RLN_VE4ebcCJHnOmMZLug_eiy3nwQPd8TOWutcY9fS7sRsZXt_PFfyL1aFNrArnpL9C8ueMIUGwGBfuIKF4XomG9NOTGOJmxU6CVUx1W0LAhqzTYsU1QpBFCJG4FGdINCSxgE-HwkaJ5Za20c7baoF4FMYwL2ak7DUmupg07KKaKQQqDaNFTRFNK7kxRVoesIngiyZoFF7RWDMLQCmkkbJklhbEFGVLJXycIxwjummGosaC70ibUX7VDMrRYEaNUmCnEAvVDi2Qhad2FwJYUHjZDmO3f_Uu_ER4Fjil1U1-rb6to1z3Frmhc3JfvH5qtyGKkfNakLv3z60Kym9B9mz3tNRbzDuQeDyoMe4jUVbpAUTMO5Afd6pvVobxdZeIvjwmjeKBGgsN1X_HEePTzWyPnLhoxNvywwt3ww8qeG4aHhS3Q1yYRECOVE1ni-StcHoErk3__aiPHxX7n9xyoM35ceD8v2sfP11_uGHU872j6ezZfMU7kyP375y5p8_zV9-d34ezeZHs8uke7_TTbbdRW0PdyDwQJgwacgKPy0UhBxS5lwonvrGyEJnJmM55mn0sJRCxozRWcFzFkA_pF5oUq37_hWyPhwN-1eJI8JQZWFe-NIUQajxv3lFw_IAZihzjdyBV7X9fXq_Xz8L0Q1yvh52N8n6ZLzbvwUu6cTctgb7BcVraY0
linkProvider ISSN International Centre
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=%EB%B6%80%EC%8B%9D%EC%84%B1+%EC%88%98%EC%A7%88%EC%A0%9C%EC%96%B4%EB%A5%BC+%EC%9C%84%ED%95%9C+%EC%88%98%EC%A7%88%EC%95%88%EC%A0%95%ED%99%94+%EB%AA%A8%EB%8D%B8+%EA%B0%9C%EB%B0%9C&rft.jtitle=%ED%95%9C%EA%B5%AD%EC%88%98%EC%B2%98%EB%A6%AC%ED%95%99%ED%9A%8C%EC%A7%80%2C+22%281%29&rft.au=%ED%99%A9%EB%B3%91%EA%B8%B0&rft.au=%EC%9A%B0%EB%8B%AC%EC%8B%9D&rft.date=2014-02-28&rft.pub=%ED%95%9C%EA%B5%AD%EC%88%98%EC%B2%98%EB%A6%AC%ED%95%99%ED%9A%8C&rft.issn=1225-7192&rft.eissn=2289-0076&rft.spage=31&rft.epage=38&rft.externalDBID=n%2Fa&rft.externalDocID=oai_kci_go_kr_ARTI_1204562
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1225-7192&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1225-7192&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1225-7192&client=summon