밀폐 박스거더형 무도장 내후성강 교량의 부식취약부에 대한 방식대책 연구(2)

This study is the second stage of developing the corrosion control technical manual about unpainted weathering steel bridge with closed box girder structures. This paper contains selection of corrosive sealant to apply into crevice of upper flange, injecting test of sealant at mock-up equipment with...

Full description

Saved in:
Bibliographic Details
Published inCorrosion science and technology Vol. 12; no. 4; pp. 191 - 197
Main Authors 송창영, Chang Young Song, 이의호, Eui Ho Lee, 이제현, Jea Hyun Lee, 박현출, Hyun Chul Park, 최재석, Jae Suk Choi, 노영태, Young Tae Noh
Format Journal Article
LanguageKorean
Published 한국부식방식학회 30.08.2013
Subjects
Online AccessGet full text
ISSN1598-6462

Cover

More Information
Summary:This study is the second stage of developing the corrosion control technical manual about unpainted weathering steel bridge with closed box girder structures. This paper contains selection of corrosive sealant to apply into crevice of upper flange, injecting test of sealant at mock-up equipment with various condition, evaluation of experiment result. Through the experiment of injection of sealants into crevice of mock-up equipment, it is proved that the tar sealant injecting corrosion control method is useful to protect corrosion at box girder upper flange corroded by remaning rain water with calcium chloride.
Bibliography:The Corrosion Science Society of Korea
KISTI1.1003/JNL.JAKO201307651680695
ISSN:1598-6462