人工肺設計のための数値解析
Numerical analysis studies for oxygenator have been conducted using a method focused on blood flow calculation, or a method that coupled flow with empirical formula or mass transfer equation. These results of each analysis would be useful information as design indexes for reduction of pressure drop,...
Saved in:
Published in | Transactions of Japanese Society for Medical and Biological Engineering Vol. 53; no. Supplement; p. S135_03 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | Japanese |
Published |
公益社団法人 日本生体医工学会
2015
Japanese Society for Medical and Biological Engineering |
Online Access | Get full text |
ISSN | 1347-443X 1881-4379 |
DOI | 10.11239/jsmbe.53.S135_03 |
Cover
Abstract | Numerical analysis studies for oxygenator have been conducted using a method focused on blood flow calculation, or a method that coupled flow with empirical formula or mass transfer equation. These results of each analysis would be useful information as design indexes for reduction of pressure drop, improvement of thromb-resistant property and enhancement of gas transfer performance to be a prerequisite for miniaturization required for the next generation of oxygenator. However, in most of oxygenators, it is not elucidated that the relationship between thrombus distribution and blood stagnant flow region after long-term use. Furthermore, most of investigations of gas transfer employ simplified numerical analysis method by focusing on oxygen transfer only. In this study, we compared the calculated flow velocity with thrombus distributions after 2 or 5 weeks continuous ECMO use in order to investigate thromb-resistant property, and compared the estimated gas transfer rates using our invented analysis method including reactions with the measured gas transfer rates in a part of oxygenator in order to investigate oxygen and carbon dioxide distributions between blood layer and gas layer. |
---|---|
AbstractList | Numerical analysis studies for oxygenator have been conducted using a method focused on blood flow calculation, or a method that coupled flow with empirical formula or mass transfer equation. These results of each analysis would be useful information as design indexes for reduction of pressure drop, improvement of thromb-resistant property and enhancement of gas transfer performance to be a prerequisite for miniaturization required for the next generation of oxygenator. However, in most of oxygenators, it is not elucidated that the relationship between thrombus distribution and blood stagnant flow region after long-term use. Furthermore, most of investigations of gas transfer employ simplified numerical analysis method by focusing on oxygen transfer only. In this study, we compared the calculated flow velocity with thrombus distributions after 2 or 5 weeks continuous ECMO use in order to investigate thromb-resistant property, and compared the estimated gas transfer rates using our invented analysis method including reactions with the measured gas transfer rates in a part of oxygenator in order to investigate oxygen and carbon dioxide distributions between blood layer and gas layer. |
Author | 巽, 英介 妙中, 義之 武輪, 能明 水野, 敏秀 片桐, 伸将 築谷, 朋典 福井, 康裕 |
Author_FL | TSUKIYA Tomonori KATAGIRI Nobumasa MIZUNO Toshihide TAKEWA Yoshiaki TATSUMI Eisuke TAENAKA Yoshiyuki FUKUI Yasuhiro |
Author_FL_xml | – sequence: 1 fullname: KATAGIRI Nobumasa – sequence: 2 fullname: TSUKIYA Tomonori – sequence: 3 fullname: TATSUMI Eisuke – sequence: 4 fullname: MIZUNO Toshihide – sequence: 5 fullname: TAKEWA Yoshiaki – sequence: 6 fullname: TAENAKA Yoshiyuki – sequence: 7 fullname: FUKUI Yasuhiro |
Author_xml | – sequence: 1 fullname: 福井, 康裕 – sequence: 1 fullname: 水野, 敏秀 – sequence: 1 fullname: 妙中, 義之 – sequence: 1 fullname: 片桐, 伸将 – sequence: 1 fullname: 巽, 英介 – sequence: 1 fullname: 武輪, 能明 – sequence: 1 fullname: 築谷, 朋典 |
BackLink | https://cir.nii.ac.jp/crid/1390282680243478912$$DView record in CiNii |
BookMark | eNo9UD1Lw0AYPqSCNfYHuAtOqe_de9fejVL8goJDFdyOS3LRhCSWpA5utlNHF1cdVOyiuAn9O7UlP8PYisv7fPDwwvNsklp2nVlCtik0KWWo9uIi9WxTYLNHUWjANVKnUlKXY1vVKo687XKOFxukURSRB0ApADBRJ7vf0-n867UcTcvJezkZz4Yfs-HTbDSsyOLhc373Ur49Lx7vt8h6aJLCNv7QIeeHB2edY7d7enTS2e-6MWOUuZyhEZJJsBhwYwMhBPg-VxgCDSFscWsEhNJiSwZcBZwqFXjKk8x6Iaeo0CE7q79ZFGk_-r2VDUyylgTGqyJSVZUd0l3F4mJgLq3u51Fq8ltt8kHkJ1YvB9ECde-m309sarPBUq3m-Y_5VybXscEf1YFssA |
ContentType | Journal Article |
Copyright | 2015 社団法人日本生体医工学会 |
Copyright_xml | – notice: 2015 社団法人日本生体医工学会 |
DBID | RYH |
DOI | 10.11239/jsmbe.53.S135_03 |
DatabaseName | CiNii Complete |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
DocumentTitleAlternate | Numerical analysis for design of oxygenators |
DocumentTitle_FL | Numerical analysis for design of oxygenators |
EISSN | 1881-4379 |
EndPage | S135_03 |
ExternalDocumentID | 130005163789 article_jsmbe_53_Supplement_53_S135_03_article_char_ja |
GroupedDBID | 2WC ALMA_UNASSIGNED_HOLDINGS JSF OK1 RJT RYH |
ID | FETCH-LOGICAL-j2212-423a58280e3d4aed5550cc493f01f0f64ea50f8e368d49d4199db9b82ebf41393 |
ISSN | 1347-443X |
IngestDate | Thu Jun 26 22:14:21 EDT 2025 Wed Sep 03 06:24:36 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | Supplement |
Language | Japanese |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-j2212-423a58280e3d4aed5550cc493f01f0f64ea50f8e368d49d4199db9b82ebf41393 |
OpenAccessLink | https://www.jstage.jst.go.jp/article/jsmbe/53/Supplement/53_S135_03/_article/-char/ja |
ParticipantIDs | nii_cinii_1390282680243478912 jstage_primary_article_jsmbe_53_Supplement_53_S135_03_article_char_ja |
PublicationCentury | 2000 |
PublicationDate | 2015 |
PublicationDateYYYYMMDD | 2015-01-01 |
PublicationDate_xml | – year: 2015 text: 2015 |
PublicationDecade | 2010 |
PublicationTitle | Transactions of Japanese Society for Medical and Biological Engineering |
PublicationTitleAlternate | 生体医工学 |
PublicationTitle_FL | TJSBME Trans. jpn. Soc. Med. Bio. Eng 生体医工学 Transactions of Japanese Society for Medical and Biological Engineering |
PublicationYear | 2015 |
Publisher | 公益社団法人 日本生体医工学会 Japanese Society for Medical and Biological Engineering |
Publisher_xml | – name: 公益社団法人 日本生体医工学会 – name: Japanese Society for Medical and Biological Engineering |
SSID | ssib001100025 ssib002484549 ssib023159591 ssj0069534 ssib020474828 ssib000937326 ssib058494337 ssib002223871 ssib046007037 ssib007484362 |
Score | 2.020474 |
Snippet | Numerical analysis studies for oxygenator have been conducted using a method focused on blood flow calculation, or a method that coupled flow with empirical... |
SourceID | nii jstage |
SourceType | Publisher |
StartPage | S135_03 |
Title | 人工肺設計のための数値解析 |
URI | https://www.jstage.jst.go.jp/article/jsmbe/53/Supplement/53_S135_03/_article/-char/ja https://cir.nii.ac.jp/crid/1390282680243478912 |
Volume | 53 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
ispartofPNX | 生体医工学, 2015, Vol.53(Supplement), pp.S135_03-S135_03 |
journalDatabaseRights | – providerCode: PRVAFT databaseName: Open Access Digital Library customDbUrl: eissn: 1881-4379 dateEnd: 99991231 omitProxy: true ssIdentifier: ssib007484362 issn: 1347-443X databaseCode: KQ8 dateStart: 20030101 isFulltext: true titleUrlDefault: http://grweb.coalliance.org/oadl/oadl.html providerName: Colorado Alliance of Research Libraries |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrR27bhQx0EpCAwXiKQIEpcCi2uBbP9YuvZc9RUggIRIp3WpfJ-UkEgRJQ8WloqShhQIQaUBUIOV3QqL7DGbsvawDFCFCWlm-2Znx7Iz3POO1x4TcrUXDhgxz7FeljERTmaiIKxX1iiZRoqqVKnAe8uEjtbImHqzL9ZnZ78GqpZ3tcql6-dd9JWexKsDArrhL9h8se8wUAFAH-0IJFobyVDammaCpxSuTNE2olTTTVMcOoqmFa7mtaE0zDm4jtVlbMQNXibHe3VLUACuGDDWjVjhy4MzdrYz6Uzen7izNEmqEYwWSLFPDHWGfpmkgkkQx7PEUIBJZRfWgFR8aBDs7fIsk2CKn_lBMj69QohRkMVQnVGce34mKXBKUULMOXyJ_Yxx_pwOHn9A0o9ZDgVEayqMdZ2BpQTHM4wNaH-kzp5A2lXY7QeI3h7rO7J4YWuw7ZaRUWyeRwNbgFkC88lJ8pmOLefm9fqDSn9KfVpmteMYGowoXSSSEO_gYBl0P0xqCd-5P0pkORT5vcvvKuWNdu_VPfoB50uMyZzzwVwLIn8NhzDGd7OjF07JZknzpBPWJLONtH84dai553rXufnnCfIqGWwLzEcQl5-IEPDxcDPE4cOvB5w3DAkxLGH7NRp9UJ-F-ai3Cr82Y35Z3aSxjJgDShckQkkgTpF0UeMYC69xs8KmN4N3EizLSry6ZmqFd3YDauf-7bsATHUFchgk3Zjc3NgJnc_USudhGiYvW6-EymRkVV8iFIHfoVXLv5_7-4Y9Pk939yd6Xyd7rg_HXg_H7g90xVI7efjt89XHy-cPRuzfXyNogW-2vRO2pJ9EoBj8ygvimwG_ZrOG1KJpaSsmqShgOf6lDNlSiKSQb6oYrXQtTi54xdWlKHTflEDxSw6-Tuc2tzeYGWRzWGjeWK6PKUqi4KrjisTaKcVEWolfNk8w_a_7Mp7bJz9YN5skCqCqvNrAEEXAeR2nMdSoSbXrxzf_Uzi1yHl9wPwN6m8xtP99pFiAm2C7vuA74C8fr0bA |
linkProvider | Colorado Alliance of Research Libraries |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=%E4%BA%BA%E5%B7%A5%E8%82%BA%E8%A8%AD%E8%A8%88%E3%81%AE%E3%81%9F%E3%82%81%E3%81%AE%E6%95%B0%E5%80%A4%E8%A7%A3%E6%9E%90&rft.jtitle=%E7%94%9F%E4%BD%93%E5%8C%BB%E5%B7%A5%E5%AD%A6&rft.au=%E7%A6%8F%E4%BA%95%2C+%E5%BA%B7%E8%A3%95&rft.au=%E6%B0%B4%E9%87%8E%2C+%E6%95%8F%E7%A7%80&rft.au=%E5%A6%99%E4%B8%AD%2C+%E7%BE%A9%E4%B9%8B&rft.au=%E7%89%87%E6%A1%90%2C+%E4%BC%B8%E5%B0%86&rft.date=2015&rft.pub=%E5%85%AC%E7%9B%8A%E7%A4%BE%E5%9B%A3%E6%B3%95%E4%BA%BA+%E6%97%A5%E6%9C%AC%E7%94%9F%E4%BD%93%E5%8C%BB%E5%B7%A5%E5%AD%A6%E4%BC%9A&rft.issn=1347-443X&rft.eissn=1881-4379&rft.volume=53&rft.issue=Supplement&rft.spage=S135_03&rft.epage=S135_03&rft_id=info:doi/10.11239%2Fjsmbe.53.S135_03&rft.externalDocID=article_jsmbe_53_Supplement_53_S135_03_article_char_ja |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1347-443X&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1347-443X&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1347-443X&client=summon |