Automated least-squares calibration of the coregistration parameters for a micro PET-CT system
A previously developed method derives co-registration parameters from PET and CT images of a four-point-source calibration phantom by manually adjusting the offsets and orientation of the CT image to achieve alignment with the PET image in a graphic viewer. This manual process is tedious and can be...
Saved in:
Published in | IEEE Nuclear Science Symposuim & Medical Imaging Conference pp. 2568 - 2572 |
---|---|
Main Authors | , , , , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.10.2010
|
Subjects | |
Online Access | Get full text |
ISBN | 9781424491063 1424491061 |
ISSN | 1082-3654 |
DOI | 10.1109/NSSMIC.2010.5874251 |
Cover
Abstract | A previously developed method derives co-registration parameters from PET and CT images of a four-point-source calibration phantom by manually adjusting the offsets and orientation of the CT image to achieve alignment with the PET image in a graphic viewer. This manual process is tedious and can be inaccurate, especially when rotational offsets exist. An automated segmentation method has been developed, based on thresholding and application of constraints on the sizes of point sources in the images. After point sources are identified on PET and CT images, co-registration is performed using an analytic rigid-body registration algorithm which is based on singular value decomposition and minimization of the co-registration error. The co-registration parameters thus derived can then be applied to co-register other PET and CT images from the same system. Twenty PET-CT images of the calibration phantom at various locations and/or orientations were obtained on a Siemens Inveon ® Multi-Modality scanner. We tested the use of from 1 to 10 data sets to derive the co-registration parameters, and found that the co-registration accuracy improves with increasing number of data sets until it stabilizes. Co-registration of PET-CT images with an accuracy of 0.33±0.11 mm has been achieved by this method on the Inveon Multi-Modality scanner. |
---|---|
AbstractList | A previously developed method derives co-registration parameters from PET and CT images of a four-point-source calibration phantom by manually adjusting the offsets and orientation of the CT image to achieve alignment with the PET image in a graphic viewer. This manual process is tedious and can be inaccurate, especially when rotational offsets exist. An automated segmentation method has been developed, based on thresholding and application of constraints on the sizes of point sources in the images. After point sources are identified on PET and CT images, co-registration is performed using an analytic rigid-body registration algorithm which is based on singular value decomposition and minimization of the co-registration error. The co-registration parameters thus derived can then be applied to co-register other PET and CT images from the same system. Twenty PET-CT images of the calibration phantom at various locations and/or orientations were obtained on a Siemens Inveon ® Multi-Modality scanner. We tested the use of from 1 to 10 data sets to derive the co-registration parameters, and found that the co-registration accuracy improves with increasing number of data sets until it stabilizes. Co-registration of PET-CT images with an accuracy of 0.33±0.11 mm has been achieved by this method on the Inveon Multi-Modality scanner. |
Author | Shikui Yan Junjun Deng Austin, D W Bing Feng Mu Chen Mintzer, R A |
Author_xml | – sequence: 1 surname: Bing Feng fullname: Bing Feng email: feng.bing@siemens.com organization: Siemens Preclinical Solutions, Knoxville, TN, USA – sequence: 2 surname: Shikui Yan fullname: Shikui Yan organization: Siemens Preclinical Solutions, Knoxville, TN, USA – sequence: 3 surname: Mu Chen fullname: Mu Chen organization: Siemens Preclinical Solutions, Knoxville, TN, USA – sequence: 4 givenname: D W surname: Austin fullname: Austin, D W organization: Siemens Preclinical Solutions, Knoxville, TN, USA – sequence: 5 surname: Junjun Deng fullname: Junjun Deng organization: Siemens Preclinical Solutions, Knoxville, TN, USA – sequence: 6 givenname: R A surname: Mintzer fullname: Mintzer, R A organization: Siemens Preclinical Solutions, Knoxville, TN, USA |
BookMark | eNpVkMtOAjEYRmvERECegE1fYPDvZTrtkkxQSfCSMGvJP52O1jAU27Lg7TWRjauT7yy-xZmQ0SEcHCFzBgvGwNy_bLfP63rB4VeUupK8ZFdkZirNJJfSMJDm-t9WYkTGDDQvhCrlLZmk9AXAQUg5Ju_LUw4DZtfRvcOUi_R9wugStbj3bcTsw4GGnuZPR22I7sOnfLFHjDi47GKifYgU6eBtDPRt1RR1Q9M5ZTfckZse98nNLpyS5mHV1E_F5vVxXS83hTeQi86KthS94qZCAGmx4h2A7ZiFXnMrhVGtbpVE0yuLpTK60lpoo2VXSuOEmJL53613zu2O0Q8Yz7tLHfEDw_lZFw |
ContentType | Conference Proceeding |
DBID | 6IE 6IH CBEJK RIE RIO |
DOI | 10.1109/NSSMIC.2010.5874251 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan (POP) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP) 1998-present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Physics |
EISBN | 9781424491049 1424491045 9781424491056 1424491053 |
EndPage | 2572 |
ExternalDocumentID | 5874251 |
Genre | orig-research |
GroupedDBID | 29I 6IE 6IF 6IH 6IK 6IL 6IN AAJGR ABLEC ADZIZ ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK CHZPO IEGSK IJVOP OCL RIE RIL RIO |
ID | FETCH-LOGICAL-i90t-dc3b53f6297a004ca72d00cd1c0f82c4396b8b64a9f6ca569878838984d549e33 |
IEDL.DBID | RIE |
ISBN | 9781424491063 1424491061 |
ISSN | 1082-3654 |
IngestDate | Wed Aug 27 02:33:52 EDT 2025 |
IsPeerReviewed | false |
IsScholarly | true |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i90t-dc3b53f6297a004ca72d00cd1c0f82c4396b8b64a9f6ca569878838984d549e33 |
PageCount | 5 |
ParticipantIDs | ieee_primary_5874251 |
PublicationCentury | 2000 |
PublicationDate | 2010-Oct. |
PublicationDateYYYYMMDD | 2010-10-01 |
PublicationDate_xml | – month: 10 year: 2010 text: 2010-Oct. |
PublicationDecade | 2010 |
PublicationTitle | IEEE Nuclear Science Symposuim & Medical Imaging Conference |
PublicationTitleAbbrev | NSSMIC |
PublicationYear | 2010 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0020344 ssj0000669446 |
Score | 1.7439244 |
Snippet | A previously developed method derives co-registration parameters from PET and CT images of a four-point-source calibration phantom by manually adjusting the... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 2568 |
SubjectTerms | Accuracy Animals Calibration Computed tomography Phantoms Positron emission tomography |
Title | Automated least-squares calibration of the coregistration parameters for a micro PET-CT system |
URI | https://ieeexplore.ieee.org/document/5874251 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LS8NAGFxqQfDkoxXf7MGj2ybZZJMcpVSK0FJohJ4s2ZeItlWbXPz1ft8mjSgevCW5JPsI38zuzCwh18Licn5iWOxrzkIZGSatbxlUMhlxG_gyR6PweCJGD-H9PJq3yE3jhTHGOPGZ6eGl28vXa1XiUlk_SoDIoV96B6ZZ5dVq1lOgdKaO2tRkC6PsKnF9wLiIwq2pK0UOtM16qu95HUfke2l_MptB-yvNV_2-HwevuLpzt0_G2y-u5CYvvbKQPfX5K8zxv006IN1vhx-dNrXrkLTM6ojsOjmo2nTI421ZrAHLGk1f8XAftnkv0ahEYUSRX-No0rWlgB4p5mA-NfG7FLPEl6ix2VDAwzSnS5T80ekwY4OMVsHRXZLdDbPBiNUnMbDn1CuYVm7gRJDGOfxUKo8D7XlK-8qzSaAA0wiZSBHmqRUqj0SaALEGJJSEGuin4fyYtFfrlTkhVEkLiNNy61kT-qGWMTfSg2dQTYPcylPSwU5avFVZG4u6f87-fnxO9txuvhPXXZB28VGaSwAJhbxys-MLTfm1SA |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3NT4MwHG0WjdGTH5vx2x482g0oFDiaZcvUbVkyTHZyoV_G6IY6uPjX-2thGI0Hb9AL0Jb83mvfe0XoimmznB8pErqSEp8HinDtagKVjAdUey5PjVF4NGaDB_9uFswa6Lr2wiilrPhMtc2l3cuXmSjMUlkniIDIGb_0ZgCsIirdWvWKChTP2JKbim6ZMLtSXu8RygJ_beuKDQtapz1V97QKJHKduDOeTqEHStVX9cQfR6_YytPfRaP1O5eCk5d2kfO2-PwV5_jfj9pDrW-PH57U1WsfNdTyAG1ZQahYNdHjTZFngGaVxK_meB-yei-MVQnDmBqGbcYTZxoDfsQmCfOpDuDFJk18YVQ2KwyIGKd4YUR_eNJLSDfBZXR0CyX9XtIdkOosBvIcOzmRwg4d8-Iwhd9KpKEnHUdIVzg68gSgGsYjzvw01kykAYsjoNaAhSJfAgFVlB6ijWW2VEcIC64Bc2qqHa1815c8pIo70Ab11Es1P0ZN00nztzJtY171z8nfzZdoe5CMhvPh7fj-FO3YvX0rtTtDG_lHoc4BMuT8ws6ULw8uuJs |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=IEEE+Nuclear+Science+Symposuim+%26+Medical+Imaging+Conference&rft.atitle=Automated+least-squares+calibration+of+the+coregistration+parameters+for+a+micro+PET-CT+system&rft.au=Bing+Feng&rft.au=Shikui+Yan&rft.au=Mu+Chen&rft.au=Austin%2C+D+W&rft.date=2010-10-01&rft.pub=IEEE&rft.isbn=9781424491063&rft.issn=1082-3654&rft.spage=2568&rft.epage=2572&rft_id=info:doi/10.1109%2FNSSMIC.2010.5874251&rft.externalDocID=5874251 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1082-3654&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1082-3654&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1082-3654&client=summon |